Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 15(4): 418-27, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15089990

RESUMEN

INTRODUCTION: Conventional electrical therapies for heart failure (HF) encompass defibrillation and ventricular resynchronization for patients at high risk for lethal arrhythmias and/or with inhomogeneous ventricular contraction. Cardiac contractility modulation (CCM) by means of nonexcitatory electrical currents delivered during the action potential plateau has been shown to acutely enhance systolic function in humans with HF. The aim of this multicenter study was to assess the chronic safety and preliminary efficacy of an implantable device delivering this novel form of electrical therapy. METHODS AND RESULTS: Thirteen patients with drug-resistant HF (New York Heart Association [NYHA] class III) were consecutively implanted with a device (OPTIMIZER II) delivering CCM biphasic square-wave pulses (20 ms, 5.8-7.7 V, 30 ms after detection of local activation) through two right ventricular leads screwed into the right aspect of the interventricular septum. CCM signals were delivered 3 hours daily over 8 weeks (3-hour phase) and 7 hours daily over the next 24 weeks (7-hour phase). Safety and feasibility of this novel therapy were regarded as primary endpoints. Preliminary clinical efficacy, -as expressed by changes in ejection fraction (EF), NYHA class, 6-minute walking test (6-MWT), peak O(2) uptake (peak VO(2)), and Minnesota Living with HF Questionnaire (MLWHFQ), was assessed at baseline and at the end of each phase. At the end of follow-up (8.8 +/- 0.2 months), all patients were alive, without heart transplantation or need for left ventricular assist device. Serial 24-hour Holter analysis revealed no proarrhythmic effect. No devices malfunctioned or failed for any reason other than end-of-battery life. Throughout the two study phases, EF improved from 22.7 +/- 7% to 28.7 +/- 7% and 37 +/- 13% (P = 0.004), 6-MWT from 418 +/- 99 m to 477 +/- 96 m and 510 +/- 107 m (P = 0.002), MLWHFQ from 36 +/- 21 to 18 +/- 12 and 7 +/- 6 (P = 0.002), peak VO(2) from 13.7 +/- 1.1 to 14.9 +/- 1.9 to 16.2 +/- 2.4 (P = 0.037), and NYHA class from 3 to 1.8 +/- 0.4 to 1.5 +/- 0.7 (P < 0.001). CONCLUSION: CCM therapy appears to be safe and feasible. Proarrhythmic effects of this novel therapy seem unlikely. Preliminary data indicate that CCM gradually and significantly improves systolic performance, symptoms, and functional status. CCM therapy for 7 hours per day is associated with greater dispersion near the mean, emphasizing the need to individually tailor CCM delivery duration. The technique appears to be attractive as an additive treatment for severe HF. Controlled randomized studies are needed to validate this novel concept.


Asunto(s)
Desfibriladores Implantables , Terapia por Estimulación Eléctrica/métodos , Insuficiencia Cardíaca/terapia , Contracción Miocárdica/fisiología , Sístole/fisiología , Enfermedad Crónica/terapia , Resistencia a Medicamentos , Terapia por Estimulación Eléctrica/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Seguridad , Encuestas y Cuestionarios , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA