Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Environ Manage ; 246: 920-928, 2019 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-31279249

RESUMEN

A bench-scale column experiment was performed to study the removal of 31 selected organic micropollutants (MPs) and phosphorus by lignite, xyloid lignite (Xylit), granular activated carbon (GAC), Polonite® and sand over a period of 12 weeks. In total 29 out of the 31 MPs showed removal efficiency >90% by GAC with an average removal of 97 ±â€¯6%. Xylit and lignite were less efficient with an average removal of 80 ±â€¯28% and 68 ±â€¯29%, respectively. The removal efficiency was found to be impacted by the characterization of the sorbents and physicochemical properties of the compounds, as well as the interaction between the sorbents and compounds. For instance, Xylit and lignite performed well for relatively hydrophobic (log octanol/water partition coefficient (Kow) ≥3) MPs, while the removal efficiency of moderately hydrophilic, highly hydrophilic and negatively charged MPs were lower. The organic sorbents were found to have more functional groups at their surfaces, which might explain the higher adsorption of MPs to these sorbents. The removal of several MPs improved after four weeks in sand, Xylit, GAC and lignite which may be related to increased biological activity and biofilm development. GAC and sand had limited ability to remove phosphorus (12 ±â€¯27% and 14 ±â€¯2%, respectively), while the calcium-silicate material Polonite® precipitated phosphorus efficiently and increased the total phosphorus removal from 12% to 96% after the GAC filter.


Asunto(s)
Contaminantes Químicos del Agua , Purificación del Agua , Adsorción , Carbón Orgánico , Fósforo , Eliminación de Residuos Líquidos , Aguas Residuales
2.
J Hazard Mater ; 328: 37-45, 2017 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-28076771

RESUMEN

A comprehensive screening of micropollutants was performed in wastewaters from on-site sewage treatment facilities (OSSFs) and urban wastewater treatment plants (WWTPs) in Sweden. A suspect screening approach, using high resolution mass spectrometry, was developed and used in combination with target analysis. With this strategy, a total number of 79 micropollutants were successfully identified, which belong to the groups of per- and polyfluoroalkyl substances (PFASs), pesticides, phosphorus-containing flame retardants (PFRs) and pharmaceuticals and personal care products (PPCPs). Results from this screening indicate that concentrations of micropollutants are similar in influents and effluents of OSSFs and WWTPs, respectively. Removal efficiencies of micropollutants were assessed in the OSSFs and compared with those observed in WWTPs. In general, removal of PFASs and PFRs was higher in package treatment OSSFs, which are based on biological treatments, while removal of PPCPs was more efficient in soil bed OSSFs. A novel comprehensive prioritization strategy was then developed to identify OSSF specific chemicals of environmental relevance. The strategy was based on the compound concentrations in the wastewater, removal efficiency, frequency of detection in OSSFs and on in silico based data for toxicity, persistency and bioaccumulation potential.


Asunto(s)
Aguas del Alcantarillado/análisis , Aguas Residuales/análisis , Aguas Residuales/toxicidad , Contaminantes Químicos del Agua/toxicidad , Simulación por Computador , Cosméticos/análisis , Cosméticos/toxicidad , Monitoreo del Ambiente , Retardadores de Llama/análisis , Retardadores de Llama/toxicidad , Espectrometría de Masas , Plaguicidas/análisis , Plaguicidas/toxicidad , Suelo/química , Eliminación de Residuos Líquidos
3.
Environ Pollut ; 159(10): 2380-6, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21784566

RESUMEN

Volatile methyl siloxanes (VMSs) are a class of chemicals with an increasing range of applications and widespread distribution in the environment. Passive air samplers (PAS) comprising sorbent-impregnated polyurethane-foam (SIP) disks were first calibrated and then deployed around two wastewater treatment plants (WWTPs) and at two landfill sites to investigate inputs of VMSs to air. SIP-derived air concentrations for ΣVMSs (ng/m(3)) at background sites on the perimeter of the WWTP were 479 ± 82.3 and comparable to results for the upwind samples at the landfills (333 ± 194). Order of magnitude higher concentrations of ΣVMSs (ng/m(3)) were found for on-site samples at the WWTPs (3980 ± 2620) and landfills (4670 ± 3360). Yearly emissions (kg/yr) to air were estimated and ranged from 60-2100 and 80-250, respectively, for the cyclic VMSs. These findings demonstrate and quantify for the first time, waste sector emissions of VMSs to the atmosphere.


Asunto(s)
Contaminantes Atmosféricos/análisis , Atmósfera/química , Monitoreo del Ambiente/métodos , Eliminación de Residuos , Siloxanos/análisis , Compuestos Orgánicos Volátiles/análisis , Contaminación del Aire , Monitoreo del Ambiente/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA