Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 15(3): 388-94, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23125355

RESUMEN

AIMS: Electromagnetic interference (EMI) can pose a danger to workers with pacemakers and implantable cardioverter-defibrillators (ICDs). At some workplaces electromagnetic fields are high enough to potentially inflict EMI. The purpose of this in vivo study was to evaluate the susceptibility of pacemakers and ICDs to external electromagnetic fields. METHODS AND RESULTS: Eleven volunteers with a pacemaker and 13 with an ICD were exposed to sine, pulse, ramp, and square waveform magnetic fields with frequencies of 2-200 Hz using Helmholtz coil. The magnetic field flux densities varied to 300 µT. We also tested the occurrence of EMI from an electronic article surveillance (EAS) gate, an induction cooktop, and a metal inert gas (MIG) welding machine. All pacemakers were tested with bipolar settings and three of them also with unipolar sensing configurations. None of the bipolar pacemakers or ICDs tested experienced interference in any of the exposure situations. The three pacemakers with unipolar settings were affected by the highest fields of the Helmholtz coil, and one of them also by the EAS gate and the welding cable. The induction cooktop did not interfere with any of the unipolarly programmed pacemakers. CONCLUSION: Magnetic fields with intensities as high as those used in this study are rare even in industrial working environments. In most cases, employees can return to work after implantation of a bipolar pacemaker or an ICD, after an appropriate risk assessment. Pacemakers programmed to unipolar configurations can cause danger to their users in environments with high electromagnetic fields, and should be avoided, if possible.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Campos Electromagnéticos/efectos adversos , Marcapaso Artificial , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Culinaria , Técnicas Electrofisiológicas Cardíacas , Exposición a Riesgos Ambientales , Diseño de Equipo , Falla de Equipo , Análisis de Falla de Equipo , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Exposición Profesional , Diseño de Prótesis , Falla de Prótesis , Soldadura , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA