Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Métodos Terapéuticos y Terapias MTCI
Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 25(3): 948-955, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36610790

RESUMEN

AIMS: The long-QT syndrome (LQTS) represents a leading cause of sudden cardiac death (SCD). The aim of this study was to assess the presence of an underlying electroanatomical arrhythmogenic substrate in high-risk LQTS patients. METHODS AND RESULTS: The present study enrolled 11 consecutive LQTS patients who had experienced frequent implantable cardioverter-defibrillator (ICD discharges triggered by ventricular fibrillation (VF). We acquired electroanatomical biventricular maps of both endo and epicardial regions for all patients and analyzed electrograms sampled from several myocardial regions. Abnormal electrical activities were targeted and eliminated by the means of radiofrequency catheter ablation. VF episodes caused a median of four ICD discharges in eleven patients (6 male, 54.5%; mean age 44.0 ± 7.8 years, range 22-53) prior to our mapping and ablation procedures. The average QTc interval was 500.0 ± 30.2 ms. Endo-epicardial biventricular maps displayed abnormally fragmented, low-voltage (0.9 ± 0.2 mV) and prolonged electrograms (89.9 ± 24.1 ms) exclusively localized in the right ventricular epicardium. We found electrical abnormalities extending over a mean epicardial area of 15.7 ± 3.1 cm2. Catheter ablation of the abnormal epicardial area completely suppressed malignant arrhythmias over a mean 12 months of follow-up (median VF episodes before vs. after ablation, 4 vs. 0; P = 0.003). After the procedure, the QTc interval measured in a 12-lead ECG analysis shortened to a mean of 461.8 ± 23.6 ms (P = 0.004). CONCLUSION: This study reveals that, among high-risk LQTS patients, regions localized in the epicardium of the right ventricle harbour structural electrophysiological abnormalities. Elimination of these abnormal electrical activities successfully prevented malignant ventricular arrhythmia recurrences.


Asunto(s)
Ablación por Catéter , Síndrome de QT Prolongado , Taquicardia Ventricular , Humanos , Masculino , Adulto Joven , Adulto , Persona de Mediana Edad , Resultado del Tratamiento , Técnicas Electrofisiológicas Cardíacas/métodos , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia , Electrocardiografía/métodos , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Síndrome de QT Prolongado/complicaciones , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
2.
BMC Complement Altern Med ; 16: 293, 2016 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-27538432

RESUMEN

BACKGROUND: Current clinical procedures for rotator cuff tears need to be improved, as a high rate of failure is still observed. Therefore, new approaches have been attempted to stimulate self-regeneration, including biophysical stimulation modalities, such as low-frequency pulsed electromagnetic fields, which are alternative and non-invasive methods that seem to produce satisfying therapeutic effects. While little is known about their mechanism of action, it has been speculated that they may act on resident stem cells. Thus, the purpose of this study was to evaluate the effects of a pulsed electromagnetic field (PST®) on human tendon stem cells (hTSCs) in order to elucidate the possible mechanism of the observed therapeutic effects. METHODS: hTSCs from the rotator cuff were isolated from tendon biopsies and cultured in vitro. Then, cells were exposed to a 1-h PST® treatment and compared to control untreated cells in terms of cell morphology, proliferation, viability, migration, and stem cell marker expression. RESULTS: Exposure of hTSCs to PST® did not cause any significant changes in proliferation, viability, migration, and morphology. Instead, while stem cell marker expression significantly decreased in control cells during cell culturing, PST®-treated cells did not have a significant reduction of the same markers. CONCLUSIONS: While PST® did not have significant effects on hTSCs proliferation, the treatment had beneficial effects on stem cell marker expression, as treated cells maintained a higher expression of these markers during culturing. These results support the notion that PST® treatment may increase the patient stem cell regenerative potential.


Asunto(s)
Magnetoterapia , Células Madre , Tendones/citología , Fenómenos Fisiológicos Celulares/efectos de la radiación , Células Cultivadas , Humanos , Células Madre/citología , Células Madre/efectos de la radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA