1.
Heart Rhythm ; 19(1): 102-112, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34534699

RESUMEN

BACKGROUND: Detailed effects of electrode size on electrograms (EGMs) have not been systematically examined. OBJECTIVES: We aimed to elucidate the effect of electrode size on EGMs and investigate an optimal configuration of electrode size and interelectrode spacing for gap detection and far-field reduction. METHODS: This study included 8 sheep in which probes with different electrode size and interelectrode spacing were epicardially placed on healthy, fatty, and lesion tissues for measurements. Between 3 electrode sizes (0.1 mm/0.2 mm/0.5 mm) with 3 mm spacing. As indices of capability in gap detection and far-field reduction, in different electrode sizes (0.1 mm/0.2 mm/0.5 mm) and interelectrode spacing (0.1 mm/0.2 mm/0.3 mm/0.5 mm/3 mm) and the optimized electrode size and interelectrode spacing were determined. Compared between PentaRay and the optimal probe determined in study 2. RESULTS: Study 1 demonstrated that unipolar voltage and the duration of EGMs increased as the electrode size increased in any tissue (P < .001). Bipolar EGMs had the same tendency in healthy/fat tissues, but not in lesions. Study 2 showed that significantly higher gap to lesion volume ratio and healthy to fat tissue voltage ratio were provided by a smaller electrode (0.2 mm or 0.3 mm electrode) and smaller spacing (0.1 mm spacing), but 0.3 mm electrode/0.1 mm spacing provided a larger bipolar voltage (P < .05). Study 3 demonstrated that 0.3 mm electrode/0.1 mm spacing provided less deflection with more discrete EGMs (P < .0001) with longer and more reproducible AF cycle length (P < .0001) compared to PentaRay. CONCLUSION: Electrode size affects both unipolar and bipolar EGMs. Catheters with microelectrodes and very small interelectrode spacing may be superior in gap detection and far-field reduction. Importantly, this electrode configuration could dramatically reduce artifactual complex fractionated atrial electrograms and may open a new era for AF mapping.


Asunto(s)
Electrodos , Técnicas Electrofisiológicas Cardíacas/instrumentación , Animales , Ablación por Catéter , Modelos Animales de Enfermedad , Diseño de Equipo , Femenino , Oveja Doméstica
2.
J Cardiovasc Electrophysiol ; 33(1): 73-80, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34822200

RESUMEN

INTRODUCTION: Direction-aware mapping algorithms improve the accuracy of voltage mapping by measuring the maximal voltage amplitude recorded in the direction of wavefront propagation. While beneficial for stationary catheters, its utility for roving catheters collecting electrograms (EGMs) at multiple angles is unknown. OBJECTIVE: To compare the directional dependence of bipolar voltage amplitude between stationary and roving catheters. METHODS: In 10 swine, a transcaval ablation line with a gap was created. The gap was mapped using an array catheter (Optrell™; Biosense Webster). In Step 1, the array was kept stationary over the gap, and four voltage maps were created during activation of the gap from superior, inferior, septal, and lateral directions. In Step 2, four additional maps were created; however, the catheter was allowed to move with points acquired at multiple angles. In Step 3, the gap was remapped; however, bipoles were computed using a direction-aware mapping algorithm. RESULTS: In a stationary catheter position, bipolar voltage distribution was influenced by the direction of activation with maximal differences obtained between orthogonal directions 32% (13%-53%). However, roving the catheter produced similar bipolar voltage maps irrespective of the direction of activation 11% (5%-18%). A direction-aware mapping algorithm was beneficial for reducing the directional dependence of voltage maps created by stationary catheters but not by roving catheters. CONCLUSION: The directional dependency of bipolar voltage amplitude is greatest when the catheter is stationary. However, when the catheter is allowed to rove and collect EGMs at multiple angles as occurs clinically, the directional dependence of bipolar voltage is minimal.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Algoritmos , Animales , Fibrilación Atrial/cirugía , Catéteres , Técnicas Electrofisiológicas Cardíacas , Porcinos
3.
J Cardiovasc Electrophysiol ; 30(5): 749-757, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30723994

RESUMEN

INTRODUCTION: Multielectrode mapping catheters improve the ability to map within the heterogeneous scar. A novel Octaray catheter with eight spines and 48 electrodes may further improve the speed and resolution of atrial mapping. The aims of this study were to (1) establish the Octaray's baseline mapping performance and electrogram (EGM) characteristics in healthy atria and to (2) determine its utility for identifying gaps in a swine model of atrial ablation lines. METHODS AND RESULTS: The right atria of eight healthy swine were mapped with Octaray and Pentaray catheters (Biosense Webster, Irvine, CA) before and after the creation of ablation lines with intentional gaps. Baseline mapping characteristics including EGM amplitude, duration, number of EGMs, and mapping time were compared. Postablation maps were created and EGM characteristics of continuous lines and gaps were correlated with pathology. Compared with Pentaray, the Octaray collected more EGMs per map (2178 ± 637 vs 1046 ± 238; P < 0.001) at a shorter mapping duration (3.2 ± 0.79 vs 6.9 ± 2.67 minutes; P < 0.001). In healthy atria, the Octaray recorded lower bipolar voltage amplitude (1.96 ± 1.83 mV vs 2.41 ± 1.92 mV; P < 0.001) while ablation gaps were characterized by higher voltage amplitude (1.24 ± 1.12 mV vs 1.04 ± 1.27 mV; P < 0.001). Ablation gaps were similarly identified by both catheters (P = 1.0). The frequency of "false gaps," defined as intact ablation lines with increased voltage amplitude was more common with Pentaray (6 vs 2) and resulted from erroneous annotation of far-field EGMs. CONCLUSION: The Octaray increases the mapping speed and density compared with the Pentaray catheter. It is as sensitive for identifying ablation gaps and more specific for mapping intact ablation lines.


Asunto(s)
Potenciales de Acción , Catéteres Cardíacos , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas/instrumentación , Atrios Cardíacos/cirugía , Frecuencia Cardíaca , Microelectrodos , Animales , Diseño de Equipo , Atrios Cardíacos/fisiopatología , Valor Predictivo de las Pruebas , Sus scrofa , Factores de Tiempo