Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Neurourol Urodyn ; 40(2): 714-721, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33508155

RESUMEN

AIMS: Sacral neuromodulation (SNM) is a guideline-recommended treatment with proven therapeutic benefit for urinary urgency incontinence (UUI) patients. The Axonics® System is the first Food and Drug Administration-approved rechargeable SNM system and is designed to deliver therapy for a minimum of 15 years. The ARTISAN-SNM study was designed to evaluate UUI participants treated with the Axonics System. Two-year follow-up results are presented. METHODS: One hundred and twenty-nine UUI participants underwent implantation with the Axonics System. Therapeutic response rate, participant quality of life (QoL), and satisfaction were determined using 3-day voiding diaries, ICIQ-OABqol, and satisfaction questionnaires. Participants were considered responders if they had a 50% or greater reduction in UUI episodes post-treatment. As-treated and Completers analyses are presented. RESULTS: At 2 years, 93% of the participants (n = 121 Completers at 2 years) were therapy responders, of which 82% achieved ≥ 75% reduction in UUI episodes and 37% were dry (100% reduction). Daily UUI episodes reduced from 5.6 ± 0.3 at baseline to 1.0 ± 0.2 at 2 years. Statistically significant improvements in ICIQ-OABqol were reported. All participants were able to recharge their device and 94% of participants reported that the recharging frequency and duration were acceptable. Participant demographics nor condition severity were correlated with clinical outcomes or recharging experience. No unanticipated or serious device-related adverse events occurred. CONCLUSIONS: At 2 years, participants treated with the Axonics System demonstrated sustained safety and efficacy, high levels of satisfaction with therapy and recharging. Participant-related factors were not associated with efficacy or recharging outcomes, indicating the reported results are applicable to a diverse population.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Calidad de Vida/psicología , Sacro/fisiopatología , Incontinencia Urinaria de Urgencia/terapia , Femenino , Estudios de Seguimiento , Humanos , Masculino , Factores de Tiempo , Resultado del Tratamiento
2.
Neurourol Urodyn ; 39(5): 1482-1488, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32339339

RESUMEN

AIMS: Sacral neuromodulation (SNM) is a guideline-recommended treatment for voiding dysfunction including urgency, urge incontinence, and nonobstructive retention as well as fecal incontinence. The Axonics® System is a miniaturized, rechargeable SNM system designed to provide therapy for at least 15 years, which is expected to significantly reduce revision surgeries as it will not require replacement as frequently as the non-rechargeable SNM system. The ARTISAN-SNM study is a pivotal study designed to treat patients with urinary urgency incontinence (UUI). Clinical results at 1-year are presented. METHODS: A total of 129 eligible UUI patients were treated. All participants were implanted with a quadripolar tined lead and neurostimulator in a single procedure. Efficacy data were collected using a 3-day bladder diary, a validated quality of life questionnaire (ICIQ-OABqol), and a participant satisfaction questionnaire. Therapy responders were defined as participants with ≥50% reduction in UUI episodes compared to baseline. Data were analyzed on all 129 participants. RESULTS: At 1 year, 89% of the participants were therapy responders. The average UUI episodes per day reduced from 5.6 ± 0.3 at baseline to 1.4 ± 0.2. Participants experienced an overall clinically meaningful improvement of 34 points on the ICIQ-OABqol questionnaire. All study participants (100%) were able to recharge their device at 1 year, and 96% of participants reported that the frequency and duration of recharging was acceptable. There were no serious device-related adverse events. CONCLUSIONS: The Axonics System is safe and effective at 1 year, with 89% of participants experiencing clinically and statistically significant improvements in UUI symptoms.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Electrodos Implantados , Plexo Lumbosacro/cirugía , Incontinencia Urinaria de Urgencia/terapia , Procedimientos Quirúrgicos Urológicos/métodos , Adulto , Anciano , Anciano de 80 o más Años , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/métodos , Electrodos Implantados/efectos adversos , Incontinencia Fecal/complicaciones , Incontinencia Fecal/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Prótesis e Implantes , Calidad de Vida , Encuestas y Cuestionarios , Resultado del Tratamiento , Incontinencia Urinaria de Urgencia/psicología , Retención Urinaria/complicaciones , Retención Urinaria/terapia , Adulto Joven
3.
Neurourol Urodyn ; 36(4): 1136-1139, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27491027

RESUMEN

INTRODUCTION: The InSite trial is a prospective, multicenter study of sacral neuromodulation (SNM) therapy with the InterStim® System in subjects with overactive bladder (OAB). One of the primary aims of the study is to report on long-term safety of the tined lead. This analysis provides detailed descriptions of device-related adverse events (AEs) and surgical interventions to 12 months. METHODS: Analysis included those subjects who completed test stimulation with a tined lead, received a full implant, and reported device-related AEs out to 12 months. A Clinical Events Committee (CEC) adjudicated AEs to 12 months. RESULTS: Device-related AEs occurred in 30% (82/272) of subjects, with only one considered serious. Fifty-six percent of the device-related AEs occurred between implant and 3 months. The most frequent device-related AEs were undesirable change in stimulation (12%, 32/272); implant site pain (7%, 20/272); and implant site infection (3%, 9/272). Of the 26 events of implant site pain, 13 required surgical intervention, with only two resulting in explant. Ten subjects experienced 13 events of a surgical site infection (including an additional cellulitis), five of which resolved with antibiotics and eight required explantation. The overall surgical intervention rate was 13% with the most common reasons being pain at the surgical site (4%), lack/loss of efficacy (4%), and infection (3%). CONCLUSIONS: Although a 30% AE rate was reported, most AEs were minor and were resolved without surgical intervention. Surgical intervention was required in 13% of subjects, with the majority being revision or replacement. Neurourol. Urodynam. 36:1136-1139, 2017. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Terapia por Estimulación Eléctrica , Vejiga Urinaria Hiperactiva/terapia , Terapia por Estimulación Eléctrica/efectos adversos , Femenino , Humanos , Plexo Lumbosacro , Masculino , Complicaciones Posoperatorias/terapia , Estudios Prospectivos , Falla de Prótesis , Reoperación , Sacro
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA