1.
IEEE Trans Biomed Eng ; 69(6): 1880-1888, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34813464

RESUMEN

OBJECTIVE: Non-invasive methods to enhance drug delivery and efficacy in the brain have been pursued for decades. Focused ultrasound hyperthermia (HT) combined with thermosensitive therapeutics have been demonstrated promising in enhancing local drug delivery to solid tumors. We hypothesized that the presence of microbubbles (MBs) combined with transcranial MR-guided focused ultrasound (MRgFUS) could be used to reduce the ultrasound power required for HT while simultaneously increasing drug delivery by locally opening the blood-brain barrier (BBB). METHODS: Transcranial HT (42 °C, 10 min) was performed in wild-type mice using a small animal MRgFUS system incorporated into a 9.4T Bruker MR scanner, with infusions of saline or Definity MBs with doses of 20 or 100 µl/kg/min (denoted as MB-20 and MB-100). MR thermometry data was continuously acquired as feedback for the ultrasound controller during the procedure. RESULTS: Spatiotemporally precise transcranial HT was achieved in both saline and MB groups. A significant ultrasound power reduction (-45.7%, p = 0.006) was observed in the MB-20 group compared to saline. Localized BBB opening was achieved in MB groups confirmed by CE-T1w MR images. There were no structural abnormalities, edema, hemorrhage, or acutemicroglial activation in all groups, confirmed by T2w MR imaging and histology. CONCLUSION: Our investigations showed that it is feasible and safe to achieve spatiotemporally precise brain HT at significantly reduced power and simultaneous localized BBB opening via transcranial MRgFUS and MBs. SIGNIFICANCE: This study provides a new synergistic brain drug delivery method with clinical translation potential.


Asunto(s)
Barrera Hematoencefálica , Hipertermia Inducida , Animales , Barrera Hematoencefálica/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Sistemas de Liberación de Medicamentos/métodos , Retroalimentación , Imagen por Resonancia Magnética/métodos , Ratones , Microburbujas
2.
Int J Hyperthermia ; 37(1): 1052-1059, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32892667

RESUMEN

PURPOSE: When doxorubicin (DOX) is administered via lyso-thermosensitive liposomes (LTLD), mild hyperthermia enhances localized delivery to heated vs. unheated tumors. The optimal LTLD dose and the impact of different doses on systemic drug distribution are unknown.Materials and methods: In this study, we evaluated local and systemic DOX delivery with three LTLD doses (0.1, 0.5, and 2.5 mg/kg) in a Vx2 rabbit tumor model. Temporally and spatially accurate controlled hyperthermia was achieved using a clinical MR-HIFU system for the intended heating duration (40 min).Results: DOX concentration in tissues delivered from LTLD combined with MR-HIFU mild hyperthermia are dose-dependent, including heated/unheated tumor, heart, and other healthy organs. Higher DOX accumulation and tumor-to-heart drug concentration ratio, defined as the ratio of DOX delivered into the tumor vs the heart, were observed in heated tumors compared to unheated tumors in all three tested doses. The DOX uptake efficiency for each mg/kg of LTLD injected IV of heated tumor was significantly higher than that of unheated tumor and heart within the tested dose range (0.1-2.5 mg/kg). The DOX uptake for the heart linearly scaled up as a function of dose while that for the heated tumor showed some evidence of saturation at the high dose of 2.5 mg/kg.Conclusions: These results provide guidance on clinical protocol design of hyperthermia-triggered drug delivery.


Asunto(s)
Hipertermia Inducida , Neoplasias , Animales , Antibióticos Antineoplásicos/uso terapéutico , Doxorrubicina/uso terapéutico , Sistemas de Liberación de Medicamentos , Hipertermia , Liposomas , Neoplasias/terapia , Conejos
3.
PLoS One ; 13(5): e0197380, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29746579

RESUMEN

Treatment of prosthetic joint infections often involves multiple surgeries and prolonged antibiotic administration, resulting in a significant burden to patients and the healthcare system. We are exploring a non-invasive method to eradicate biofilm on metal implants utilizing high-frequency alternating magnetic fields (AMF) which can achieve surface induction heating. Although proof-of-concept studies demonstrate the ability of AMF to eradicate biofilm in vitro, there is a legitimate safety concern related to the potential for thermal damage to surrounding tissues when considering heating implanted metal objects. The goal of this study was to explore the feasibility of detecting acoustic emissions associated with boiling at the interface between a metal implant and surrounding soft tissue as a wireless safety sensing mechanism. Acoustic emissions generated during in vitro and in vivo AMF exposures were captured with a hydrophone, and the relationship with surface temperature analyzed. The effect of AMF exposure power, surrounding media composition, implant location within the AMF transmitter, and implant geometry on acoustic detection during AMF therapy was also evaluated. Acoustic emissions were reliably identified in both tissue-mimicking phantom and mouse studies, and their onset coincided with the implant temperature reaching the boiling threshold. The viscosity of the surrounding medium did not impact the production of acoustic emissions; however, emissions were not present when the medium was oil due to the higher boiling point. Results of simulations and in vivo studies suggest that short-duration, high-power AMF exposures combined with acoustic sensing can be used to minimize the amount of thermal damage in surrounding tissues. These studies support the hypothesis that detection of boiling associated acoustic emissions at a metal/tissue interface could serve as a real-time, wireless safety indicator during AMF treatment of biofilm on metallic implants.


Asunto(s)
Biopelículas , Hipertermia Inducida/métodos , Campos Magnéticos , Metales , Prótesis e Implantes , Infecciones Relacionadas con Prótesis/terapia , Acústica , Animales , Simulación por Computador , Femenino , Análisis de Elementos Finitos , Calor , Humanos , Rodilla , Ratones , Modelos Estadísticos , Necrosis , Seguridad del Paciente , Fantasmas de Imagen , Propiedades de Superficie , Tecnología Inalámbrica
4.
Sci Rep ; 7(1): 7520, 2017 08 08.
Artículo en Inglés | MEDLINE | ID: mdl-28790407

RESUMEN

Treatment of prosthetic joint infection (PJI) usually requires surgical replacement of the infected joint and weeks of antibiotic therapy, due to the formation of biofilm. We introduce a non-invasive method for thermal destruction of biofilm on metallic implants using high-frequency (>100 kHz) alternating magnetic fields (AMF). In vitro investigations demonstrate a >5-log reduction in bacterial counts after 5 minutes of AMF exposure. Confocal and scanning electron microscopy confirm removal of biofilm matrix components within 1 minute of AMF exposure, and combination studies of antibiotics and AMF demonstrate a 5-log increase in the sensitivity of Pseudomonas aeruginosa to ciprofloxacin. Finite element analysis (FEA) simulations demonstrate that intermittent AMF exposures can achieve uniform surface heating of a prosthetic knee joint. In vivo studies confirm thermal damage is confined to a localized region (<2 mm) around the implant, and safety can be achieved using acoustic monitoring for the presence of surface boiling. These initial studies support the hypothesis that AMF exposures can eradicate biofilm on metal implants, and may enhance the effectiveness of conventional antibiotics.


Asunto(s)
Antibacterianos/farmacología , Biopelículas/efectos de los fármacos , Ciprofloxacina/farmacología , Campos Magnéticos , Infecciones Relacionadas con Prótesis/terapia , Infecciones por Pseudomonas/terapia , Pseudomonas aeruginosa/efectos de los fármacos , Animales , Biopelículas/crecimiento & desarrollo , Bovinos , Simulación por Computador , Matriz Extracelular de Sustancias Poliméricas/efectos de los fármacos , Femenino , Análisis de Elementos Finitos , Ratones , Pruebas de Sensibilidad Microbiana , Prótesis e Implantes/microbiología , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/patología , Infecciones por Pseudomonas/microbiología , Infecciones por Pseudomonas/patología , Pseudomonas aeruginosa/crecimiento & desarrollo
5.
Int J Hyperthermia ; 32(6): 673-87, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27210733

RESUMEN

UNLABELLED: There is growing interest in performing hyperthermia treatments with clinical magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) therapy systems designed for tissue ablation. During hyperthermia treatment, however, due to the narrow therapeutic window (41-45 °C), careful evaluation of the accuracy of proton resonant frequency (PRF) shift MR thermometry for these types of exposures is required. PURPOSE: The purpose of this study was to evaluate the accuracy of MR thermometry using a clinical MR-HIFU system equipped with a hyperthermia treatment algorithm. METHODS: Mild heating was performed in a tissue-mimicking phantom with implanted temperature sensors using the clinical MR-HIFU system. The influence of image-acquisition settings and post-acquisition correction algorithms on the accuracy of temperature measurements was investigated. The ability to achieve uniform heating for up to 40 min was evaluated in rabbit experiments. RESULTS: Automatic centre-frequency adjustments prior to image-acquisition corrected the image-shifts in the order of 0.1 mm/min. Zero- and first-order phase variations were observed over time, supporting the use of a combined drift correction algorithm. The temperature accuracy achieved using both centre-frequency adjustment and the combined drift correction algorithm was 0.57° ± 0.58 °C in the heated region and 0.54° ± 0.42 °C in the unheated region. CONCLUSION: Accurate temperature monitoring of hyperthermia exposures using PRF shift MR thermometry is possible through careful implementation of image-acquisition settings and drift correction algorithms. For the evaluated clinical MR-HIFU system, centre-frequency adjustment eliminated image shifts, and a combined drift correction algorithm achieved temperature measurements with an acceptable accuracy for monitoring and controlling hyperthermia exposures.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Hipertermia Inducida , Animales , Femenino , Imagen por Resonancia Magnética , Neoplasias/diagnóstico por imagen , Neoplasias/cirugía , Neoplasias/terapia , Conejos , Termometría
6.
Int J Hyperthermia ; 31(8): 813-22, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26540488

RESUMEN

PURPOSE: Localised hyperthermia in rodent studies is challenging due to the small target size. This study describes the development and characterisation of an MRI-compatible high-intensity focused ultrasound (HIFU) system to perform localised mild hyperthermia treatments in rodent models. MATERIAL AND METHODS: The hyperthermia platform consisted of an MRI-compatible small animal HIFU system, focused transducers with sector-vortex lenses, a custom-made receive coil, and means to maintain systemic temperatures of rodents. The system was integrated into a 3T MR imager. Control software was developed to acquire images, process temperature maps, and adjust output power using a proportional-integral-derivative feedback control algorithm. Hyperthermia exposures were performed in tissue-mimicking phantoms and in a rodent model (n = 9). During heating, an ROI was assigned in the heated region for temperature control and the target temperature was 42 °C; 30 min mild hyperthermia treatment followed by a 10-min cooling procedure was performed on each animal. RESULTS: 3D-printed sector-vortex lenses were successful at creating annular focal regions which enables customisation of the heating volume. Localised mild hyperthermia performed in rats produced a mean ROI temperature of 42.1 ± 0.3 °C. The T10 and T90 percentiles were 43.2 ± 0.4 °C and 41.0 ± 0.3 °C, respectively. For a 30-min treatment, the mean time duration between 41-45 °C was 31.1 min within the ROI. CONCLUSIONS: The MRI-compatible HIFU system was successfully adapted to perform localised mild hyperthermia treatment in rodent models. A target temperature of 42 °C was well-maintained in a rat thigh model for 30 min.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Hipertermia Inducida , Animales , Diseño de Equipo , Ultrasonido Enfocado de Alta Intensidad de Ablación/instrumentación , Imagen por Resonancia Magnética , Masculino , Modelos Animales , Fantasmas de Imagen , Ratas Sprague-Dawley , Programas Informáticos