Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Expert Rev Med Devices ; 18(5): 493-498, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33970735

RESUMEN

OBJECTIVES: The aim of this study is to demonstrate how Electrophysiology activity has been impacted by the pandemic Coronavirus disease 2019 (COVID-19). METHODS: In this multicenter retrospective study, we analyze all consecutive patients admitted for electrophysiological procedures during the COVID-19 lockdown in the Tuscany region of Italy, comparing them to patients hospitalized in the corresponding period of the previous year. RESULTS: The impact of COVID-19 on cardiac arrhythmia management was impressive, with a reduction of more than 50% in all kinds of procedures. A gender gap was observed, with a more relevant reduction for female patients. Arrhythmic urgencies requiring a device implant showed a reduced time from symptoms to first medical contact but the time from first medical contact to procedure was significantly prolonged. CONCLUSION: Hospitals need to consider how outbreaks may affect health systems beyond the immediate infection. Routine activity should be based on a risk assessment between the prompt performance of procedure and its postponement. Retrospective observational analysis such as this study could be decisive in evidence-based medicine of any future pathogen outbreak.Nonstandard Abbreviations and Acronyms PM= pacemakerICD= implantable cardioverter defibrillatorECV= electrical cardioversionEPS= electrophysiological studyAP= ablations proceduresCIED= cardiac implantable electronic devicesWCD= wearable cardioverter defibrillatorEP Lab= Electrophysiology LaboratoriesAVNRT =atrioventricular nodal reentry tachycardiaAVRT= atrioventricular reentry tachycardiaAFL= atrial flutterAF= atrial fibrillationVT= ventricular tachycardiaAT= atrial tachycardia.


Asunto(s)
COVID-19/epidemiología , Atención a la Salud , Brotes de Enfermedades , Técnicas Electrofisiológicas Cardíacas , Anciano , Arritmias Cardíacas/fisiopatología , Desfibriladores Implantables , Femenino , Humanos , Italia/epidemiología , Masculino , Marcapaso Artificial , Pandemias , Estudios Retrospectivos , SARS-CoV-2 , Factores de Tiempo
2.
G Ital Cardiol (Rome) ; 21(10): 768-778, 2020 Oct.
Artículo en Italiano | MEDLINE | ID: mdl-32968314

RESUMEN

Electrical storm (ES) is defined as three or more episodes of sustained ventricular tachycardia (VT) or fibrillation (VF) within 24 h, or an incessant VT/VF lasting more than 12 h. It usually occurs in implantable cardioverter-defibrillator (ICD) recipients, and three or more device interventions are typically used for the diagnosis. ES incidence is particularly high in case of ICD implanted in secondary prevention (10-30%), with recurrences occurring in up to 80% of patients. A comprehensive evaluation of triggers, predictive factors of high-risk patients and an appropriate management of the acute/subacute and chronic phases are pivotal to reduce mortality and recurrences. Medical therapy with antiarrhythmic and anesthetic drugs, with appropriate device reprogramming and neuroaxial modulation if needed, are used to cool down the ES, which should ultimately be treated with ablation therapy or, less often, with an alternative treatment, such as denervation or stereotactic radiosurgery. An optimization of the clinical pathway in a network modeling is crucial to achieve the best treatment, eventually addressing patients to centers with VT ablation programs, and identifying the most challenging procedures and the most critical patients that should be treated only in high-volume tertiary centers. In this paper, we present a proposal of healthcare network modeling for ES treatment in a regional setting.


Asunto(s)
Modelos Teóricos , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Anestésicos/administración & dosificación , Antiarrítmicos/administración & dosificación , Vías Clínicas , Desfibriladores Implantables/efectos adversos , Atención a la Salud , Sinapsis Eléctricas , Humanos , Incidencia , Factores de Riesgo , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Fibrilación Ventricular/fisiopatología
3.
Int J Cardiovasc Imaging ; 36(9): 1599-1607, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32447632

RESUMEN

To evaluate predictors of zero-X ray procedures for supraventricular arrhythmias (SVT) using minimally fluoroscopic approach (MFA). Patients referred for RF catheter ablation of SVT were admitted for a MFA with an electro-anatomical navigation system or a conventional fluoroscopic approach (ConvA). Exclusion criterion was the need to perform a transseptal puncture. 206 patients (98 men, age 53 ± 19 years) underwent an EP study, 93 (45%) with an MFA and 113 (55%) with a ConvA. Fifty-five had no inducible arrhythmias (EPS). Fifty-four had AV nodal reentrant tachycardia (AVNRT), 49 patients had typical atrial flutter (AFL), 37 had AV reciprocating tachycardia (AVRT/WPW), 11 had focal atrial tachycardia (AT), and underwent a RF ablation. X-ray was not used at all in 51/93 (58%) procedures (zero X ray). MFA was associated with a significant reduction in total fluoroscopy time (5.5 ± 10 vs 13 ± 18 min, P = 0.01) and operator radiation dose (0.8 ± 2.5 vs 3 ± 8.2 mSV, P < 0.05). The greatest absolute dose reduction was observed in AVNRT (0.1 ± 0.3 vs 5.1 ± 10 mSV, P = 0.01, 98% relative dose reduction) and in AFL (1.3 ± 3.6 vs 11 ± 16 mSV, P = 0.003, 88% relative dose reduction) groups. Both AVNRT or AFL resulted the only statistically significant predictors of zero x ray at multivariate analysis (OR 4.5, 95% CI 1.5-13 and OR 5, 95% CI 1.7-15, P < 0.001, respectively). Success and complication rate was comparable between groups (P = NS). Using MFA for SVT ablation, radiological exposure is significantly reduced. Type of arrhythmia is the strongest predictor of zero X ray procedure.


Asunto(s)
Aleteo Atrial/cirugía , Ablación por Catéter , Exposición Profesional/prevención & control , Dosis de Radiación , Exposición a la Radiación/prevención & control , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Taquicardia Supraventricular/cirugía , Potenciales de Acción , Adulto , Anciano , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Femenino , Fluoroscopía , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Exposición Profesional/efectos adversos , Seguridad del Paciente , Exposición a la Radiación/efectos adversos , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico por imagen , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Taquicardia Supraventricular/diagnóstico por imagen , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
4.
J Cardiovasc Med (Hagerstown) ; 20(5): 271-277, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30624298

RESUMEN

: Cardiac implantable electronic device (CIED) implantation has greatly increased, with an associated exponential increase in CIED infections (CDIs). Cardiac device related infective endocarditis (CDRIE) has high morbidity and mortality: approximately 10-21%. Therefore, a prompt diagnosis and radical treatment of CDRIE are needed; transvenous lead extraction (TLE) is the mainstay for the complete healing, even if associated with wide logistic problems, high therapeutic costs and high mortality risk for patients. Some criticisms about the value of Duke criteria and their limitations for the diagnosis of CDRIE are known. The significance of classic laboratory data, transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE), considered in the Duke score, are reviewed and critically discussed in this article, with regard to the specific field of the diagnosis of CDI. The need for new techniques for achieving the diagnostic reliability has been well perceived by physicians, and additional techniques have been introduced in the new European Society of Cardiology (ESC) and British Heart Rhythm Society (BHRS) guidelines on infective endocarditis. These suggested techniques, such as 18-Fluorodeoxyglucose PET/computed tomography (FDG-PET/CT), white blood cell PET (WBC PET) and lung multislice CT (MSCT), are also discussed in the study. This short review is intended as an extensive summary of the diagnostic workflow in cases of CDI and will be useful for readers who want to know more about this issue.


Asunto(s)
Vías Clínicas , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/cirugía , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/cirugía , Flujo de Trabajo , Antibacterianos/uso terapéutico , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/mortalidad , Endocarditis Bacteriana/microbiología , Endocarditis Bacteriana/mortalidad , Humanos , Valor Predictivo de las Pruebas , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/mortalidad , Factores de Riesgo , Resultado del Tratamiento
5.
Europace ; 16(8): 1236-9, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25074974

RESUMEN

Cardiac device implantation is the most common of all invasive cardiac electrophysiological procedures. Over 250 000 devices are implanted each year in Europe. The purpose of this European Heart Rhythm Association (EHRA) survey was to assess the facilities, personnel, and protocols of members of the EHRA electrophysiology (EP) research network involved in device implantation. There were 68 responses to the questionnaire. The survey responses were mainly (84%) from medium- to high-volume device implanting centres, performing >200 implants per year, with over 50% performing >400 implants per year. Most consultants are male (85%), half of all centres had no female consultants, and only one in six had more than one female consultant. There is trend towards specialization in device implantation. The combination of device implantation and EP is still common (76% of all centres) but only 34% of centres have consultants performing device implantation and coronary intervention. Moreover, 23% of centres have all device implantation performed by consultants who do not perform any other types of procedure. Cardiac device implantation as a day case is the planned admission for routine elective device implantation in 30% of hospitals, 47% of hospitals have a single night stay, and 23% of hospitals have admission durations of two or more nights. Device implantation is available as a 24 h service, 365 days a year in 38% of hospitals. The commonest other model was as a daytime service on weekdays in 45% of hospitals.


Asunto(s)
Estimulación Cardíaca Artificial/tendencias , Desfibriladores Implantables/tendencias , Cardioversión Eléctrica/tendencias , Hospitales de Alto Volumen/tendencias , Cuerpo Médico de Hospitales/tendencias , Marcapaso Artificial/tendencias , Médicos Mujeres/tendencias , Pautas de la Práctica en Medicina/tendencias , Atención Posterior/tendencias , Cardioversión Eléctrica/instrumentación , Técnicas Electrofisiológicas Cardíacas/tendencias , Europa (Continente) , Femenino , Encuestas de Atención de la Salud , Humanos , Tiempo de Internación/tendencias , Masculino , Admisión del Paciente/tendencias , Admisión y Programación de Personal/tendencias , Valor Predictivo de las Pruebas , Derivación y Consulta/tendencias , Encuestas y Cuestionarios , Resultado del Tratamiento , Recursos Humanos , Carga de Trabajo
6.
JACC Cardiovasc Imaging ; 6(10): 1075-1086, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24011775

RESUMEN

OBJECTIVES: The aim of this study was to investigate the diagnostic performance of (99m)Tc-hexamethypropylene amine oxime labeled autologous white blood cell ((99m)Tc-HMPAO-WBC) scintigraphy in patients with suspected infections associated with cardiovascular implantable electronic devices (CIEDs). BACKGROUND: Early, definite recognition of CIED-related infections combined with accurate localization and quantification of disease burden is a prerequisite for optimal treatment strategies. METHODS: All 63 consecutive patients underwent clinical examination, blood chemistry, microbiology, and echography of the cardiac region/venous pathway of the device. Final diagnosis of infection was established in 32 of 63 patients and in 23 of 32 by microbiology. RESULTS: Sensitivity of (99m)Tc-HMPAO-WBC single-photon emission computed tomography/computed tomography (SPECT/CT) was 94% for both detection and localization of CIED-associated infection. SPECT/CT imaging had a definite added diagnostic value over both planar and stand-alone SPECT. Pocket infection was often associated with lead(s) involvement; the intracardiac portion of the lead(s) more frequently exhibited (99m)Tc-HMPAO-WBC accumulation and presented the highest rate of complications, infectious endocarditis, and septic embolism. Two false negative cases and no false positive results were observed. None of the patients with negative (99m)Tc-HMPAO-WBC scintigraphy developed CIED-related infection during follow-up of 12 months. Echography of the cardiac region/venous pathway of the device had 90% specificity, but low sensitivity (81% when intracardiac lead[s] infection only was considered). The Duke criteria had 31% sensitivity for the definite category (100% specificity) and 81% for the definite and possible categories (77% specificity). CONCLUSIONS: (99m)Tc-HMPAO-WBC scintigraphy enabled the confirmation of the presence of CIED-associated infection, definition of the extent of device involvement, and detection of associated complications. Moreover, (99m)Tc-HMPAO-WBC scintigraphy reliably excluded device-associated infection during a febrile episode and sepsis, with 95% negative predictive value.


Asunto(s)
Transfusión de Sangre Autóloga , Desfibriladores Implantables/efectos adversos , Transfusión de Leucocitos , Leucocitos/diagnóstico por imagen , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Radiofármacos , Exametazima de Tecnecio Tc 99m , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Anciano , Anciano de 80 o más Años , Técnicas Bacteriológicas , Reacciones Falso Negativas , Femenino , Hospitales Universitarios , Humanos , Italia , Masculino , Persona de Mediana Edad , Imagen Multimodal/métodos , Valor Predictivo de las Pruebas , Pronóstico , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/terapia , Estudios Retrospectivos , Factores de Tiempo , Tomografía Computarizada por Rayos X
7.
Europace ; 15(9): 1333-6, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23978838

RESUMEN

The purpose of this European Heart Rhythm Association (EHRA) survey is to assess the implementation and use of imaging techniques in cardiac electrophysiology (EP) and device procedures across European cardiovascular centres. Forty European centres, all members of the EHRA EP research network, responded to this survey. Thirty-one centres (88%) use transthoracic echocardiography (TTE) to evaluate left atrial size and/or volume before atrial fibrillation (AF) ablation. Sixteen centres (46%) perform delayed-enhancement cardiac magnetic resonance imaging (MRI) to guide ventricular tachycardia ablation. Electroanatomical mapping (EAM) systems are available in >65% of responding centres and the use of robotic catheter and remote magnetic navigation systems is limited to <10%. Fusion of EAM data with cardiac computed tomography (CT) and/or MRI is performed in up to 43% of AF ablation procedures. Seventeen out of 35 (49%) responding centres also perform TTE to predict a favourable response to cardiac resynchronization therapy (CRT). Imaging of the cardiac venous system with CT and identification of myocardial scar using CT or MRI, is not routinely performed in the majority of centres [32 (91%) and 26 (75%) centres, respectively) prior to CRT. This EHRA survey shows that several imaging techniques are used to guide catheter ablation and CRT procedures in European centres. Echocardiographic imaging, EAM techniques, and cardiac CT/MRI are commonly used.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/estadística & datos numéricos , Técnicas Electrofisiológicas Cardíacas/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Prótesis e Implantes/estadística & datos numéricos , Radiografía Intervencional/estadística & datos numéricos , Cirugía Asistida por Computador/estadística & datos numéricos , Humanos
8.
Mycopathologia ; 175(1-2): 129-34, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23073824

RESUMEN

We report on the treatment with micafungin of a pacemaker-associated endocarditis due to Candida albicans. Antifungal therapy was able to reduce vegetation size from 5 to 1 cm making possible the transvenous removal of the device without a high risk of pulmonary embolism. Noteworthy, a high micafungin concentration was documented into the lead vegetation (10 µg/g of vegetation tissue) and this may have contributed to the striking size reduction of vegetation.


Asunto(s)
Antifúngicos/uso terapéutico , Candida albicans/aislamiento & purificación , Equinocandinas/uso terapéutico , Endocarditis/diagnóstico , Endocarditis/tratamiento farmacológico , Lipopéptidos/uso terapéutico , Marcapaso Artificial/efectos adversos , Prótesis e Implantes/efectos adversos , Anciano , Candida albicans/efectos de los fármacos , Ecocardiografía , Endocarditis/microbiología , Endocarditis/patología , Femenino , Humanos , Micafungina , Pruebas de Sensibilidad Microbiana , Resultado del Tratamiento
9.
Circ Arrhythm Electrophysiol ; 4(6): 844-50, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21946316

RESUMEN

BACKGROUND: The role of pacing sites and atrial electrophysiology on the progression of atrial fibrillation (AF) to the permanent form in patients with sinus node dysfunction (SND) has never been investigated. The aim of the study was to investigate the relationship between atrial electrophysiology and the efficacy of atrial pacing at the low interatrial septum (IAS) or at the right atrial appendage (RAA) to prevent persistent/permanent AF in patients with SND. METHODS AND RESULTS: The Electrophysiology-Guided Pacing Site Selection (EPASS) Study was a prospective, controlled, randomized study. Atrial refractoriness, basal and incremental conduction times from the RAA to the coronary sinus ostium were measured before implantation, and the difference (ΔCTos) was calculated. Patients with ΔCTos ≥ 50 ms (study group) and those with ΔCTos <50 ms (control group) were randomly assigned to RAA or IAS with algorithms for continuous atrial stimulation "on." The primary end point was time to development of permanent or persistent AF within a 2-year follow-up in the study group, IAS versus RAA. Data were analyzed by intention to treat. One hundred two patients (77 ± 7 years, 44 mol/L) were enrolled, 69 (68%) in the study group and 33 (32%) in the control group. Of these, 97 ended the study, respectively, randomly assigned: 29 IAS versus 36 RAA and 18 IAS versus 14 RAA. After a mean follow-up of 15 ± 7 (median, 17) months, 11 (16.6%) patients in the study group met the primary end point: 2 IAS versus 9 RAA (log rank=3.93, P=0.047). CONCLUSIONS: In patients with SND and intra-atrial conduction delay, low IAS pacing was superior to RAA pacing in preventing progression to persistent or permanent AF. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00239226.


Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial/prevención & control , Tabique Interatrial/fisiopatología , Estimulación Cardíaca Artificial/métodos , Técnicas Electrofisiológicas Cardíacas , Síndrome del Seno Enfermo/terapia , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Progresión de la Enfermedad , Femenino , Humanos , Italia , Estimación de Kaplan-Meier , Masculino , Selección de Paciente , Valor Predictivo de las Pruebas , Estudios Prospectivos , Periodo Refractario Electrofisiológico , Síndrome del Seno Enfermo/complicaciones , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
10.
J Cardiovasc Med (Hagerstown) ; 10(1): 51-8, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19708226

RESUMEN

OBJECTIVE: Myotonic dystrophy type 1 (DM1) is the most frequent muscular dystrophy in adults. DM1 is a multisystem disorder also affecting the heart with an increased incidence of sudden death, which has been explained with the common impairment of the conduction system often requiring pacemaker implantation; however, the occurrence of sudden death despite pacemaker implantation and the observation of major ventricular arrhythmias generated the hypothesis that ventricular arrhythmias may play a causal role as well. The aim of the study was to assess the 2-year cumulative incidence and the value of noninvasive and invasive findings as predictive factors for sudden death, resuscitated cardiac arrest, ventricular fibrillation, sustained ventricular tachycardia and severe sinus dysfunction or high-degree atrioventricular block. METHODS/DESIGN: More than 500 DM1 patients will be evaluated at baseline with a clinical interview, 12-lead ECG, 24-h ECG and echocardiogram. Conventional and nonconventional indications to electrophysiological study, pacemaker, implantable cardioverter defibrillator or loop recorder implantation have been developed. In the case of an indication to electrophysiological study, pacemaker, implantable cardioverter defibrillator or loop recorder implant at baseline or at follow-up, the patient will be referred for the procedure. At the end of 2-year follow-up, all candidate prognostic factors will be tested for their association with the endpoints. TRIAL REGISTRATION: ClinicalTrials.gov ID NCT00127582. CONCLUSION: The available evidence supports the hypothesis that both bradyarrhythmias and tachyarrhythmias may cause sudden death in DM1, but the course of cardiac disease in DM1 is still unclear. We expect that this large, prospective, multicenter study will provide evidence to improve diagnostic and therapeutic strategies in DM1.


Asunto(s)
Arritmias Cardíacas/etiología , Distrofia Miotónica/complicaciones , Proyectos de Investigación , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/prevención & control , Bloqueo Atrioventricular/etiología , Estimulación Cardíaca Artificial , Reanimación Cardiopulmonar , Muerte Súbita Cardíaca/etiología , Desfibriladores Implantables , Progresión de la Enfermedad , Supervivencia sin Enfermedad , Ecocardiografía , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Paro Cardíaco/etiología , Paro Cardíaco/terapia , Humanos , Italia , Estimación de Kaplan-Meier , Masculino , Distrofia Miotónica/diagnóstico , Distrofia Miotónica/terapia , Marcapaso Artificial , Valor Predictivo de las Pruebas , Estudios Prospectivos , Medición de Riesgo , Taquicardia Ventricular/etiología , Factores de Tiempo , Fibrilación Ventricular/etiología
11.
J Cardiovasc Med (Hagerstown) ; 10(9): 693-8, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19512941

RESUMEN

INTRODUCTION: Pacemaker and implantable cardioverter defibrillator infections, when not treated, lead to serious consequences. The aim is to identify the prevalent strains of the responsible bacteria to guide an effective therapy. METHODS: Between May 2003 and April 2008, 118 leads were extracted from 61 patients, with chronic draining sinus, pocket infection, pacemaker endocarditis, or sepsis. Following extraction, samples of the leads underwent cultural and antibiogram examination. RESULTS: Staphylococcus epidermidis was the most frequently isolated bacterial strain (37.7%), followed by Gram-positive flora (16.1%), Staphylococcus aureus (14.3%), Candida parapsilosis (5.4%), Staphylococcus schleiferi (5.4%), Corynebacterium species, and Staphylococcus hominis (3.6%). Cultures were negative in 14.3% of the samples. Retained sensitivity to antibiotics were reported as follows: teicoplanin/vancomycin 100%, doxicyclin 96%, amikacin 94%, piperacillin-tazobactam 58%, cotrimoxazole 78%, gentamycin 65%, quinolones 47%, rifampicin 44%, cephalosporins 25%, and oxacillin 25%. Within staphylococci, involved in about 60% of the infections, S. hominis and S. epidermidis showed the highest antibiotic resistance. In case of sepsis, sensitivity was retained for glycopeptides and amikacin (about 100%), and to a lower degree for doxicyclin (80%). Arbitrarily stratifying into recent (<3 months) and chronic (>3 months) infections, an increase in time prior to referral for lead extraction was associated with a significant increase in antibiotic resistance. CONCLUSION: Bacteria associated with pacemaker and implantable cardioverter defibrillator-related infections, staphylococci in about 60% of the cases, show poor susceptibility to antibiotics, presenting three out of four methicillin-resistant features. Therefore, systemic antibiotics, mainly glycopeptides, must not be delayed awaiting the complete removal of the implanted system.


Asunto(s)
Antibacterianos/uso terapéutico , Desfibriladores Implantables/microbiología , Marcapaso Artificial/microbiología , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Sepsis/microbiología , Anciano , Anciano de 80 o más Años , Remoción de Dispositivos , Farmacorresistencia Bacteriana Múltiple , Humanos , Resistencia a la Meticilina , Pruebas de Sensibilidad Microbiana , Persona de Mediana Edad , Selección de Paciente , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/cirugía , Sepsis/tratamiento farmacológico , Sepsis/cirugía , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA