Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Radiology ; 286(1): 71-80, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28809582

RESUMEN

Purpose To show that equal coronary lumen opacification can be achieved with iso- and low-osmolar contrast media when it is injected at the same iodine delivery rate with contemporary cardiac computed tomographic (CT) protocols and to investigate the cardiovascular effect of iso-osmolar contrast media and the image quality achieved. Materials and Methods Institutional review board approval and written informed consent were obtained for the Effect of Iso-osmolar Contrast Medium on Coronary Opacification and Heart Rhythm in Coronary CT Angiography, or IsoCOR, trial. Between November 2015 and August 2016, 306 patients (167 [55%] women) at least 18 years old (weight range, 50-125 kg), were prospectively randomized to receive iso-osmolar iodixanol 270 or low-osmolar iopromide 300 contrast media. All coronary segments were assessed for intraluminal opacification and image quality and were compared by using the Student t test. Heart rate, arrhythmia, patient discomfort, and adverse events also were monitored. Results Mean measured coronary attenuation values ± standard deviation were comparable between the iodixanol 270 and iopromide 300 contrast media groups (469 HU ± 167 vs 447 HU ± 166, respectively [P = .241]; 95% confidence interval: -15.1, 60.0), including those from subanalyses. Adjusted for the lower iodine concentration, the mean iodixanol 270 bolus was larger compared with that of iopromide 300 (76.8 mL ± 11.6 vs 69.7 mL ± 10.8, respectively; P < .001). The higher injection rate was associated with higher pressure (777 kPa ± 308 vs 630 kPa ± 252, respectively; P < .001). Although in the iodixanol 270 group patients experienced less heat discomfort (72% vs 86%, respectively; P < .001), no differences in heart rate or rhythm were observed. Conclusion If injected at comparable iodine delivery rates, the iso-osmolar contrast medium iodixanol 270 is not inferior to low-osmolar contrast medium iopromide 300 for assessment of coronary opacification. Iodixanol 270 was associated with less heat discomfort, but did not affect heart rate differently compared with iopromide 300. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste/uso terapéutico , Angiografía Coronaria , Yohexol/análogos & derivados , Ácidos Triyodobenzoicos/uso terapéutico , Adulto , Presión Sanguínea/efectos de los fármacos , Angiografía por Tomografía Computarizada/métodos , Angiografía por Tomografía Computarizada/estadística & datos numéricos , Medios de Contraste/efectos adversos , Angiografía Coronaria/métodos , Angiografía Coronaria/estadística & datos numéricos , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Yohexol/efectos adversos , Yohexol/uso terapéutico , Masculino , Persona de Mediana Edad , Factores de Riesgo , Ácidos Triyodobenzoicos/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA