1.
Ann Vasc Surg ; 73: 585-588, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33556523

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has proven over the years to be a viable alternative to open surgery. A rare but severe complication is represented by the valve migration. We report a case of TAVI complication due to the loss of the prosthetic valve in the abdominal aorta treated by endovascular approach. METHODS: An 88-year-old patient with severe aortic valve stenosis, symptomatic for dyspnea was proposed for a TAVI because considered at high risk for surgery. During the TAVI procedure, the undeployed device (Edwards SAPIEN 3 - Edwards Lifesciences, Irvine, CA, USA) detached from its delivery system. Several attempts to withdraw the valve fluctuating in the aorta into its supporting system were performed without success. An emergency endovascular treatment was promptly planned to obtain the exclusion from the flow of the embolized valve. Under local anaesthesia, through the percutaneous femoral access already present, a tube aortic endograft (EndurantTM II, Medtronic, Santa Rosa, CA; ETTF2828C70EE) was successfully introduced and deployed in the infrarenal aorta without any related complications. The embolized valve was completely covered by the endgraft and thus fixed to the aortic wall. The first postoperative computer tomography angiography (CTA) confirmed the correct placement of the endograft, the exclusion of the valve from the flow and the patency of the great vessels. No perioperative or postoperative complications were recorded. The patient was discharged on the ninth postoperative day with the indication to a new attempt of TAVI, through transapical access. CONCLUSIONS: In case of intraprocedural loss of an undeplyed valve during TAVI, the valve fixing through endograft deployment in infrarenal aorta is a possible solution.


Asunto(s)
Aorta Abdominal , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Migración de Cuerpo Extraño/etiología , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Aorta Abdominal/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Procedimientos Endovasculares , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/terapia , Humanos , Masculino , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA