Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Med (Hagerstown) ; 21(4): 292-298, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32068573

RESUMEN

INTRODUCTION: Atrial fibrillation ablation has historically been guided by fluoroscopy, with the related enhanced risk deriving from radiation. Fluoroscopy exposure may be confined to guide the transseptal puncture. Small sample size study presented a new methodology to perform a totally fluoroless atrial fibrillation ablation in the case of a patent foramen ovale (PFO). We evaluated this methodology in a large sample size of patients and a multicentre experience. METHODS AND RESULTS: Two hundred and fifty paroxysmal atrial fibrillation patients referred for first atrial fibrillation ablation with a CARTO3 electroanatomic mapping system were enrolled. In 58 out of 250 patients, a PFO allowed crossing of the interatrial septum, and a completely fluoroless ablation was performed applying the new method (Group A). In the remaining patients, a standard transseptal puncture was performed (Group B). Pulmonary vein isolation was achieved in all patients with comparable procedural and clinical outcomes at short- and long-term follow-up. CONCLUSION: The presence of a PFO may allow a completely fluoroless well tolerated and effective atrial fibrillation ablation. Probing the fossa ovalis looking for the PFO during the procedure is desirable, as it is not time-consuming and can potentially be done in every patient undergoing atrial fibrillation ablation.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Foramen Oval Permeable , Venas Pulmonares/cirugía , Cirugía Asistida por Computador , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Foramen Oval Permeable/diagnóstico por imagen , Frecuencia Cardíaca , Humanos , Italia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Cirugía Asistida por Computador/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
3.
Europace ; 10(4): 506-8, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18339613

RESUMEN

AIMS: An antiarrhythmic effect of spinal cord stimulation (SCS) has been recognized in an animal model. The actual mechanism is still mainly unknown. An adrenergic output reduction has been advocated as the main mechanism, although a modulation effect on the arrhythmic substrate has not yet been investigated. We studied T-wave alternans (TWA) modifications to test the hypothesis that SCS affects the arrhythmic substrate. METHODS AND RESULTS: We performed TWA assessment in three high-risk patients who previously had undergone implantation of both implantable cardioverter defibrillator and SCS to treat refractory angina. The test was performed after switching off the SCS and after 2 and 24 h stimulation at the default amplitude. The protocol was executed 2 months apart in order to assess the reproducibility of the results, collecting a total of 18 TWA reports. In all the three patients, we observed a significant reduction of TWA amplitude after 2 h stimulation. All the tests were classified as negative after 24 h stimulation with the nominal parameters. CONCLUSION: Spinal cord stimulation results in a decrease in the TWA magnitude, and thus it seems to positively affect the arrhythmic substrate in a time-dependent manner.


Asunto(s)
Cardiomiopatías/terapia , Terapia por Estimulación Eléctrica/métodos , Electrocardiografía , Isquemia Miocárdica/terapia , Médula Espinal/fisiología , Anciano , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Cardiomiopatías/fisiopatología , Sistema de Conducción Cardíaco/fisiología , Frecuencia Cardíaca/fisiología , Humanos , Isquemia Miocárdica/fisiopatología , Proyectos Piloto , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA