Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Talanta ; 252: 123897, 2023 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-36067699

RESUMEN

This work proposes an automated strategy for the inorganic selenium speciation in infusion tea samples, employing an MSFIA-CVG-AFS system and sodium tetrahydroborate for chemical vapor generation. The selenium total is determined after an online prereduction step of selenium (VI) to selenium (IV) in alkaline media, using a UV reactor with a 15 W Hg lamp. Selenium (IV) is quantified directly on the sample, and selenium (VI) is determined by the difference between the total selenium and selenium (IV) concentrations. The optimization of the chemical parameters: hydrochloric acid - hydrobromide acid solution concentration, potassium iodide concentration, sodium hydroxide concentration, and sodium tetrahydroborate concentration was performed using a (24-1) two-level fractional factorial design. The validation parameters were determined for total selenium and selenium (IV), and the results found were: limits of detection and quantification of 0.05 and 0.18 µg L-1, respectively; a linear range of 0.18-5.0 µg L-1, precision expressed as the relative standard deviation of 2.1% for a sample number of 10, for both analytes. The system allows the speciation analysis with an injection throughput of 15 injections per hour. This analytical method was applied for inorganic selenium speciation in nine infusions of tea samples purchased commercially in supermarkets in Palma de Mallorca City, Spain. The concentrations of selenium (IV) and total selenium varied from 0.2 to 0.6 µg L-1 and 0.4-2.0 µg L-1, respectively. The accuracy method was evaluated using spike tests, and the recoveries achieved varied from 91 to 111%.


Asunto(s)
Selenio , Selenio/análisis , Espectrometría de Fluorescencia , Borohidruros , , Espectrofotometría Atómica/métodos
2.
Anal Sci ; 38(10): 1323-1332, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35876988

RESUMEN

A simple one-step drawing for the cost-effective fabrication of microfluidic paper-based analytical devices (µPADs) for the determination of phosphate content in water and fertilizer samples is presented in this paper. The hydrophobic barrier of µPAD was patterned using a 2-mm tip marker pen using a transparent acrylic sheet template. The molybdenum blue reaction using ascorbic acid as a reducing agent was used. A pre-concentration step of samples is proposed to improve the sensitivity of the measurement. The blue complex produced on the µPADs was recorded using a smartphone camera. The color intensities (red, green, blue and gray) were analyzed using ImageJ program. The proposed µPAD method provides a linear calibration range from 0 to 100 mg L-1 P. The limit of detection (LOD) was found to be 0.7 mg L-1 P with a precision of 3.1%RSD for 50 mg L-1 P (n = 10). The proposed method was successfully applied to the determination of phosphorus contents in water and liquid chemical fertilizer samples. The results obtained from µPAD agreed with a spectrophotometric method using paired t test at a 95% confidence level.


Asunto(s)
Técnicas Analíticas Microfluídicas , Papel , Ácido Ascórbico , Fertilizantes , Microfluídica , Fosfatos , Fósforo , Sustancias Reductoras , Agua/química
3.
Molecules ; 27(4)2022 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-35209114

RESUMEN

In this work, a flow-based spectrofluorimetric method for iodine determination was developed. The system consisted of a miniaturized chip-based flow manifold for solutions handling and with integrated spectrofluorimetric detection. A multi-syringe module was used as a liquid driver. Iodide was quantified from its catalytic effect on the redox reaction between Ce(IV) and As(III), based on the Sandell-Kolthoff reaction. The method was applied for the determination of iodine in salt, pharmaceuticals, supplement pills, and seaweed samples without off-line pre-treatment. An in-line oxidation process, aided by UV radiation, was implemented to analyse some samples (supplement pills and seaweed samples) to eliminate interferences and release iodine from organo-iodine compounds. This feature, combined with the fluorometric reaction, makes this method simpler, faster, and more sensitive than the classic approach of the Sandell-Kolthoff reaction. The method allowed iodine to be determined within a range of 0.20-4.0 µmol L-1, with or without the in-line UV digestion, with a limit of detection of 0.028 µmol L-1 and 0.025 µmol L-1, respectively.


Asunto(s)
Yodo/análisis , Preparaciones Farmacéuticas/análisis , Sales (Química)/análisis , Espectrometría de Fluorescencia/instrumentación , Espectrometría de Fluorescencia/métodos , Digestión , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Fluorescencia/normas , Jeringas
4.
Food Chem ; 367: 130673, 2022 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-34352693

RESUMEN

In this work, the use of a multisyringe flow injection analysis coupled to hydride generation atomic fluorescence spectrometry (MSFIA-HG-AFS) for inorganic selenium chemical speciation was proposed. A Doehlert design was applied to optimize the experimental conditions for hydride generation (NaBH4 and HCl concentrations). The limits of quantification (LoQ) obtained were 0.07 µg L-1, for total inorganic Se, and 0.08 µg L-1, for Se(IV). Accuracy and precision of the proposed analytical method were evaluated through analysis of standard reference material and addition and recovery tests. The optimized method was applied to analyses of eight samples of beer, produced in Spain, obtaining concentrations for Se(IV) (<0.08 - 0.46 ± 0.01 µg L-1), total inorganic Se (0.47 ± 0.01 - 3.04 ± 0.62 µg L-1) and Se(VI) (0.06 ± 0.01 - 3.00 ± 0.59 µg L-1). The proposed analytical method was accurate, precise and sensitivity for determination of selenium species in beer samples.


Asunto(s)
Selenio , Cerveza , Análisis de Inyección de Flujo , Selenio/análisis , Espectrometría de Fluorescencia , Espectrofotometría Atómica
5.
J Pharm Biomed Anal ; 164: 353-359, 2019 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-30439662

RESUMEN

Subcritical water extracts of chokeberry (Aronia melanocarpa) stems were chemically and biologically characterised. Chemical profile was defined by GC-MS analysis whereas anti-oxidant, anti-diabetic and tyrosinase-inhibitory activities of the extracts were investigated by in vitro assays. Antioxidant activity assays revealed strong activity against DPPH radical (IC50 = 0.1 mg/mL) and reducing power (IC50 = 0.25 mg/mL). The extracts demonstrated remarkable amylase (0.59 mmol ACAE/g) and glucosidase (7.50 mmol ACAE/g) inhibitory effects. Anti-tyrosinase activity of aronia stem extracts obtained by subcritical water was calculated to be 15.87 mg KAE/g extract. GC-MS analysis of chokeberry stem subcritical water extracts revealed the presence of different chemical classes. The compounds present in the highest concentrations were polyols arabitol (13.7%), xylitol (3.5%), and glycerol (1.96%), as well as sugars such as fructose (3.04%), ribose (1.99%) and xylulose (1.18%).


Asunto(s)
Antioxidantes/farmacología , Inhibidores de Glicósido Hidrolasas/farmacología , Monofenol Monooxigenasa/antagonistas & inhibidores , Photinia/química , Extractos Vegetales/farmacología , Antioxidantes/análisis , Antioxidantes/química , Antioxidantes/aislamiento & purificación , Compuestos de Bifenilo/química , Pruebas de Enzimas/métodos , Cromatografía de Gases y Espectrometría de Masas/instrumentación , Cromatografía de Gases y Espectrometría de Masas/métodos , Inhibidores de Glicósido Hidrolasas/análisis , Inhibidores de Glicósido Hidrolasas/química , Inhibidores de Glicósido Hidrolasas/aislamiento & purificación , Concentración 50 Inhibidora , Monosacáridos/análisis , Monosacáridos/química , Monosacáridos/aislamiento & purificación , Monosacáridos/farmacología , Oxidación-Reducción/efectos de los fármacos , Picratos/química , Extractos Vegetales/análisis , Extractos Vegetales/química , Extractos Vegetales/aislamiento & purificación , Tallos de la Planta/química , Alcoholes del Azúcar/análisis , Alcoholes del Azúcar/química , Alcoholes del Azúcar/aislamiento & purificación , Alcoholes del Azúcar/farmacología , Agua/química
6.
Anal Bioanal Chem ; 410(7): 1943-1953, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29387951

RESUMEN

Cherry stems have been used in traditional medicine mostly for the treatment of urinary tract infections. Extraction with subcritical water, according to its selectivity, efficiency and other aspects, differs substantially from conventional extraction techniques. The complexity of plant subcritical water extracts is due to the ability of subcritical water to extract different chemical classes of different physico-chemical properties and polarities in a single run. In this paper, dispersive liquid-liquid microextraction (DLLME) with simultaneous derivatisation was optimised for the analysis of complex subcritical water extracts of cherry stems to allow simple and rapid preparation prior to gas chromatography-mass spectrometry (GC-MS). After defining optimal extracting and dispersive solvents, the optimised method was used for the identification of compounds belonging to different chemical classes in a single analytical run. The developed sample preparation protocol enabled simultaneous extraction and derivatisation, as well as convenient coupling with GC-MS analysis, reducing the analysis time and number of steps. The applied analytical protocol allowed simple and rapid chemical screening of subcritical water extracts and was used for the comparison of subcritical water extracts of sweet and sour cherry stems. Graphical abstract DLLME GC MS analysis of cherry stem extracts obtained by subcritical water.


Asunto(s)
Cromatografía de Gases y Espectrometría de Masas/métodos , Microextracción en Fase Líquida/métodos , Extractos Vegetales/química , Tallos de la Planta/química , Prunus avium/química , Aldehídos/análisis , Diseño de Equipo , Ácidos Grasos/análisis , Cromatografía de Gases y Espectrometría de Masas/instrumentación , Microextracción en Fase Líquida/instrumentación , Fenoles/análisis , Agua/química
7.
J Sep Sci ; 41(9): 2012-2019, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29377562

RESUMEN

The application of layered double hydroxide-Al2 O3 -polymer mixed-matrix disks for solid-phase extraction is reported for the first time. Al2 O3 is embedded in a polymer matrix followed by an in situ metal-exchange process to obtain a layered double hydroxide-Al2 O3 -polymer mixed-matrix disk with excellent flow-through properties. The extraction performance of the prepared disks is evaluated as a proof of concept for the automated extraction using sequential injection analysis of organic acids (p-hydroxybenzoic acid, 3,4-dihydroxybenzoic acid, gallic acid) following an anion-exchange mechanism. After the solid-phase extraction, phenolic acids were quantified by reversed-phase high-performance liquid chromatography with diode-array detection using a core-shell silica-C18 stationary phase and isocratic elution (acetonitrile/0.5% acetic acid in pure water, 5:95, v/v). High sensitivity and reproducibility were obtained with limits of detection in the range of 0.12-0.25 µg/L (sample volume, 4 mL), and relative standard deviations between 2.9 and 3.4% (10 µg/L, n = 6). Enrichment factors of 34-39 were obtained. Layered double hydroxide-Al2 O3 -polymer mixed-matrix disks had an average lifetime of 50 extractions. Analyte recoveries ranged from 93 to 96% for grape juice and nonalcoholic beer samples.


Asunto(s)
Óxido de Aluminio/química , Hidróxidos/química , Hidroxibenzoatos/química , Polímeros/química , Extracción en Fase Sólida , Automatización , Cerveza/análisis , Cromatografía Líquida de Alta Presión , Jugos de Frutas y Vegetales/análisis , Límite de Detección , Microscopía Electrónica de Rastreo , Reproducibilidad de los Resultados
8.
Talanta ; 167: 398-403, 2017 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-28340738

RESUMEN

The release of 226Ra from phosphogypsum (PG) was evaluated by developing a novel tool for fully automated 226Ra lixiviation from PG integrating extraction/pre-concentration using a renewable sorbent format. Eight leached fractions (30mL each one) and a residual fraction were analyzed allowing the evaluation of dynamic lixiviation of 226Ra. An automatic system allows this approach coupling a homemade cell with a 226Ra extraction/pre-concentration method, which is carried out combining two procedures: Ra adsorption on MnO2 and its posterior co-precipitation with BaSO4. Detection was carried out with a low-background proportional counter, obtaining a minimum detectable activity of 7Bqkg-1. Method was validated by analysis of a PG reference material (MatControl CSN-CIEMAT 2008), comparing the content found in fractions (sum of leached fractions + residual fraction) to the reference value. PG samples from Huelva (Spain) were studied. 226Ra average activity concentration of the sum of leached fractions with artificial rainwater at pH 5.4±0.2 was 105±3Bqkg-1d.w. representing a 226Ra lixiviation of 37%; while at pH 2.0±0.2, it was 168±3Bqkg-1 d.w., which represents a 50%. Also, static lixiviation, maintaining the same experimental conditions, was carried out indicating that, for both considered pH, the 226Ra release from PG is up to 50% higher in a dynamic leaching that in a static one, may have both environmental and reutilization implications.


Asunto(s)
Sulfato de Calcio/química , Fósforo/química , Radio (Elemento)/aislamiento & purificación , Extracción en Fase Sólida/métodos , Automatización , Radio (Elemento)/análisis , Reproducibilidad de los Resultados
9.
Food Chem ; 212: 759-67, 2016 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-27374593

RESUMEN

A novel fully-automated magnetic stirring-assisted lab-in-syringe analytical procedure has been developed for the fast and efficient dispersive liquid-liquid microextraction (DLLME) of caffeine in coffee beverages. The procedure is based on the microextraction of caffeine with a minute amount of dichloromethane, isolating caffeine from the sample matrix with no further sample pretreatment. Selection of the relevant extraction parameters such as the dispersive solvent, proportion of aqueous/organic phase, pH and flow rates have been carefully evaluated. Caffeine quantification was linear from 2 to 75mgL(-1), with detection and quantification limits of 0.46mgL(-1) and 1.54mgL(-1), respectively. A coefficient of variation (n=8; 5mgL(-1)) of a 2.1% and a sampling rate of 16h(-1), were obtained. The procedure was satisfactorily applied to the determination of caffeine in brewed, instant and decaf coffee samples, being the results for the sample analysis validated using high-performance liquid chromatography.


Asunto(s)
Bebidas/análisis , Cafeína/análisis , Café/química , Microextracción en Fase Líquida/métodos , Automatización , Cromatografía Líquida de Alta Presión/métodos , Solventes/química , Jeringas
10.
Talanta ; 84(5): 1259-66, 2011 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-21641435

RESUMEN

In this work, a miniaturized, completely enclosed multisyringe-flow system is proposed for high-throughput purification of RuBisCO from Triticum aestivum extracts. The automated method capitalizes on the uptake of the target protein at 4°C onto Q-Sepharose Fast Flow strong anion-exchanger packed in a cylindrical microcolumn (105 × 4 mm) followed by a stepwise ionic-strength gradient elution (0-0.8 mol/L NaCl) to eliminate concomitant extract components and retrieve highly purified RuBisCO. The manifold is furnished downstream with a flow-through diode-array UV/vis spectrophotometer for real-time monitoring of the column effluent at the protein-specific wavelength of 280 nm to detect the elution of RuBisCO. Quantitation of RuBisCO and total soluble proteins in the eluate fractions were undertaken using polyacrylamide gel electrophoresis (PAGE) and the spectrophotometric Bradford assay, respectively. A comprehensive investigation of the effect of distinct concentration gradients on the isolation of RuBisCO and experimental conditions (namely, type of resin, column dimensions and mobile-phase flow rate) upon column capacity and analyte breakthrough was effected. The assembled set-up was aimed to critically ascertain the efficiency of preliminary batchwise pre-treatments of crude plant extracts (viz., polyethylenglycol (PEG) precipitation, ammonium sulphate precipitation and sucrose gradient centrifugation) in terms of RuBisCO purification and absolute recovery prior to automated anion-exchange column separation. Under the optimum physical and chemical conditions, the flow-through column system is able to admit crude plant extracts and gives rise to RuBisCO purification yields better than 75%, which might be increased up to 96 ± 9% with a prior PEG fractionation followed by sucrose gradient step.


Asunto(s)
Cromatografía por Intercambio Iónico/métodos , Análisis de Inyección de Flujo/métodos , Extractos Vegetales/química , Ribulosa-Bifosfato Carboxilasa/análisis , Ribulosa-Bifosfato Carboxilasa/aislamiento & purificación , Triticum/química , Automatización , Análisis de Inyección de Flujo/instrumentación , Concentración de Iones de Hidrógeno , Jeringas , Temperatura , Factores de Tiempo
11.
Anal Bioanal Chem ; 400(10): 3585-94, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21573729

RESUMEN

A smart fully automated system is proposed for determination of thorium and uranium in a wide concentration range, reaching environmental levels. The hyphenation of lab-on-valve (LOV) and multisyringe flow injection analysis (MSFIA), coupled to a long path length liquid waveguide capillary cell, allows the spectrophotometric determination of thorium and uranium in different types of environmental sample matrices achieving high selectivity and sensitivity levels. Online separation and preconcentration of thorium and uranium is carried out by means of Uranium and TEtraValents Actinides resin. The potential of the LOV-MSFIA makes possible the full automation of the system by the in-line regeneration of the column and its combination with a smart methodology is a step forward in automation. After elution, thorium(IV) and uranium(VI) are spectrophotometrically detected after reaction with arsenazo-III. We propose a rapid, inexpensive, and fully automated method to determine thorium(IV) and uranium(VI) in a wide concentration range (0-1,200 and 0-2,000 µg L(-1) Th and U, respectively). Limits of detection reached are 5.9 ηg L(-1) of uranium and 60 ηg L(-1) of thorium. Different water sample matrices (seawater, well water, freshwater, tap water, and mineral water), and a channel sediment reference material which contained thorium and uranium were satisfactorily analyzed with the proposed method.


Asunto(s)
Extracción en Fase Sólida/métodos , Torio/análisis , Uranio/análisis , Contaminantes Radiactivos del Agua/análisis , Análisis de Inyección de Flujo , Agua Dulce/análisis , Sistemas en Línea , Agua de Mar/análisis
12.
Anal Bioanal Chem ; 397(2): 871-8, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20237918

RESUMEN

Rapid and fully automated multisyringe flow-injection analysis (MSFIA) with a multi-pumping flow system (MPFS) coupled to a long path-length liquid waveguide capillary cell (LWCC) is proposed for the determination of uranium(VI) at ultra trace levels. On-line separation and pre-concentration of uranium is carried out by means of a TRU resin. After elution, uranium(VI) is spectrophotometrically detected after reaction with arsenazo-III. Combination of the MSFIA and MPFS techniques with the TRU-resin enables the analysis to be performed in a short time, using large sample volumes and achieving high selectivity and sensitivity levels. A detection limit of 12.6 ng L(-1) (ppt) is reached for a 100-mL sample volume. The versatility of the proposed method also enables pre-concentration of variable sample volumes, enabling application of the analysis to a wide concentration range. Reproducibility of better than 5% and a resin durability of 40 injections should be emphasized. The developed method was successfully applied to different types of environmental sample matrices with recoveries between 95 and 108%.


Asunto(s)
Monitoreo del Ambiente/métodos , Análisis de Inyección de Flujo/métodos , Espectrofotometría/métodos , Uranio/análisis , Contaminantes Radiactivos del Agua/análisis , Sulfato de Calcio/análisis , Monitoreo del Ambiente/economía , Análisis de Inyección de Flujo/economía , Límite de Detección , Fósforo/análisis , Espectrofotometría/economía , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA