Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
2.
Int J Cardiol ; 351: 42-47, 2022 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-34954276

RESUMEN

INTRODUCTION: The presence of bipolar low-voltage zone (LVZ) is a predictor of AF recurrence after PV isolation (PVI). However, changes of wavefront and bipole directions may cause different electrogram characteristics. We aimed to investigate whether using omnipolar maximum voltage (Vmax) map derived from high density (HD) Grid mapping catheter could assess LVZ and AF ablation outcome accurately. METHODS: Fifty paroxysmal AF patients (27 males, 57.8 ± 9.5 years old) who underwent 3D mapping guided PVI were enrolled. Left atrial voltage mapping during sinus rhythm before ablation was performed. The significant LVZ (<0.5 mV with area > 5 cm2) were defined as sites by omnipolar Vmax, bipolar HD wave map, conventional bipolar electrograms acquired from electrode pairs along to and across to the catheter shaft. The primary end point was the first documented recurrence of any AF during follow-ups. RESULTS: PVI was performed in all patients, and there were 2 patients (4%) who also received additional non-PV triggers ablation. After a follow-up of 11.4 ± 5.4 months, recurrence of AF occurred in 12 patients (24%). The presence of a significant LVZ was less detected by omnipolar Vmax map, compared to HD wave map (24.0% vs. 58.0%, p = 0.001). LVZ detected by omnipolar Vmax map independently predicted the AF recurrence (odds ratio 16.91; 95% CI, 3.17-90.10; p = 0.001). CONCLUSION: LVZ detected by omnipolar Vmax map accurately predicts the AF recurrence following ablation in paroxysmal AF, compared to conventional bipolar and HD wave maps, suggesting the omnipolar Vmax map can precisely define the atrial substrate property.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
3.
Pacing Clin Electrophysiol ; 44(10): 1724-1732, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34449092

RESUMEN

BACKGROUND: Atrial fibrillation (AF) prevalence increases with age. Aging affects the substrate properties of the left atrium (LA) and the outcomes of catheter ablation for treating AF. We investigated the AF trigger distribution and catheter ablation outcomes in patients of different ages with AF. METHODS: 1585 patients with AF (1181 paroxysmal and 404 non- paroxysmal AF) who had undergone catheter ablation were enrolled. The patients were divided into young (20-40 year-old, n = 175), middle-aged (41-64 year-old, n = 1134), and old (≥ 65 year-old, n = 276) groups. Electrophysiological characteristics and AF trigger sites were recorded. RESULT: The incidence of AF with only non-pulmonary vein (non-PV) foci was higher in the young group than in the other groups (8.6% vs. 3.6% vs. 3.3%, p < 0.01). Non-PV foci were more commonly located in the superior vena cava (SVC) in the young group than in the other groups (13.1% vs. 7.8% vs. 6.5%, p = 0.03). The left atrium (LA) mean voltage was higher and the incidence of very late recurrence after AF ablation was lower in the young group than in the other groups. However, the final AF recurrence rate after multiple procedures and complication rates were similar among all the groups at a mean follow-up of 5.6 years. CONCLUSION: The young patients with AF had a higher incidence of only non-PV foci, mostly located in SVC, than the middle-aged and old patients. Our study highlights the importance of identifying the non-PV foci in catheter ablation of young patients with AF.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Adulto , Factores de Edad , Anciano , Técnicas Electrofisiológicas Cardíacas , Femenino , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Recurrencia
4.
BMC Cardiovasc Disord ; 21(1): 387, 2021 08 09.
Artículo en Inglés | MEDLINE | ID: mdl-34372779

RESUMEN

BACKGROUND: Transmural lesion creation is essential for effective atrial fibrillation (AF) ablation. Lesion characteristics between conventional energy and high-power short-duration (HPSD) setting in contact force-guided (CF) ablation for AF remained unclear. METHODS: Eighty consecutive AF patients who received CF with conventional energy setting (power control: 25-30 W, force-time integral = 400 g s, n = 40) or with HPSD (power control: 40-50 W, 10 s, n = 40) ablation were analyzed. Of them, 15 patients in each conventional and HPSD group were matched by age and gender respectively for ablation lesions analysis. Type A and B lesions were defined as a lesion with and without significant voltage reduction after ablation, respectively. The anatomical distribution of these lesions and ablation outcomes among the 2 groups were analyzed. RESULTS: 1615 and 1724 ablation lesions were analyzed in the conventional and HPSD groups, respectively. HPSD group had a higher proportion of type A lesion compared to conventional group (P < 0.01). In the conventional group, most type A lesions were at the right pulmonary vein (RPV) posterior wall (50.2%) whereas in the HPSD group, most type A lesions were at the RPV anterior wall (44.0%) (P = 0.04). The procedure time and ablation time were significantly shorter in the HPSD group than that in the conventional group (91.0 ± 12.1 vs. 124 ± 14.2 min, P = 0.03; 30.7 ± 19.2 vs. 57.8 ± 21 min, P = 0.02, respectively). At a mean follow-up period of 11 ± 1.4 months, there were 13 and 7 patients with recurrence in conventional and HPSD group respectively (P = 0.03). CONCLUSION: Optimal ablation lesion characteristics and distribution after conventional and HPSD ablation differed significantly. HPSD ablation had shorter ablation time and lower recurrence rate than did conventional ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/lesiones , Factores de Edad , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Estudios de Casos y Controles , Ablación por Catéter/instrumentación , Ablación por Catéter/estadística & datos numéricos , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Venas Pulmonares/fisiopatología , Recurrencia , Factores Sexuales , Materiales Inteligentes , Factores de Tiempo , Resultado del Tratamiento
6.
J Cardiovasc Electrophysiol ; 32(7): 1921-1930, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33834555

RESUMEN

INTRODUCTION: Identifying the critical isthmus (CI) in scar-related macroreentrant atrial tachycardia (AT) is challenging, especially for patients with cardiac surgery. We aimed to investigate the electrophysiological characteristics of scar-related macroreentrant ATs in patients with and without cardiac surgery. METHODS: A prospective study of 31 patients (mean age 59.4 ± 9.81 years old) with scar-related macroreentrant ATs were enrolled for investigation of substrate properties. Patients were categorized into the nonsurgery (n = 18) and surgery group (n = 13). The CIs were defined by concealed entrainment, conduction velocity less than 0.3 m/s, and the presence of local fractionated electrograms. RESULTS: Among the 31 patients, a total of 65 reentrant circuits and 76 CIs were identified on the coherent map. The scar in the surgical group is larger than the nonsurgical group (18.81 ± 9.22 vs. 10.23 ± 5.34%, p = .016). The CIs in surgical group have longer CI length (15.27 ± 4.89 vs. 11.20 ± 2.96 mm, p = .004), slower conduction velocity (0.46 ± 0.19 vs. 0.69 ± 0.14 m/s, p < .001), and longer total activation time (45.34 ± 9.04 vs. 38.24 ± 8.41%, p = .016) than those in the nonsurgical group. After ablation, 93.54% of patients remained in sinus rhythm during a follow-up of 182 ± 19 days. CONCLUSION: The characteristics of the isthmus in macroreentrant AT are diverse, especially for surgical scar-related AT. The identification of CIs can facilitate the successful ablation of scar-related ATs.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Taquicardia Supraventricular , Anciano , Cicatriz/diagnóstico , Cicatriz/etiología , Cicatriz/patología , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/patología , Sistema de Conducción Cardíaco/cirugía , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
7.
Biochim Biophys Acta Mol Basis Dis ; 1867(5): 166088, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33515676

RESUMEN

Point mutation in alcohol dehydrogenase 2 (ALDH2), ALDH2*2 results in decreased catalytic enzyme activity and has been found to be associated with different human pathologies. Whether ALDH2*2 would induce cardiac remodeling and increase the attack of atrial fibrillation (AF) remains poorly understood. The present study evaluated the effect of ALDH2*2 mutation on AF susceptibility and unravelled the underlying mechanisms using a multi-omics approach including whole-genome gene expression and proteomics analysis. The in-vivo electrophysiological study showed an increase in the incidence and reduction in the threshold of AF for the mutant mice heterozygous for ALDH2*2 as compared to the wild type littermates. The microarray analysis revealed a reduction in the retinoic acid signals which was accompanied by a downstream reduction in the expression of voltage-gated Na+ channels (SCN5A). The treatment of an antagonist for retinoic acid receptor resulted in a decrease in SCN5A transcript levels. The integrated analysis of the transcriptome and proteome data showed a dysregulation of fatty acid ß-oxidation, adenosine triphosphate synthesis via electron transport chain, and activated oxidative responses in the mitochondria. Oral administration of Coenzyme Q10, an essential co-factor known to meliorate mitochondrial oxidative stress and preserve bioenergetics, conferred a protection against AF attack in the mutant ALDH2*2 mice. The multi-omics approach showed the unique pathophysiology mechanisms of concurrent dysregulated SCN5A channel and mitochondrial bioenergetics in AF. This inspired the development of a personalized therapeutic agent, Coenzyme Q10, to protect against AF attack in humans characterized by ALDH2*2 genotype.


Asunto(s)
Aldehído Deshidrogenasa Mitocondrial/fisiología , Fibrilación Atrial/patología , Metabolismo Energético , Mitocondrias/patología , Mutación , Canales de Sodio/metabolismo , Transcriptoma , Animales , Fibrilación Atrial/etiología , Fibrilación Atrial/metabolismo , Redes Reguladoras de Genes , Masculino , Ratones , Mitocondrias/metabolismo , Transducción de Señal , Canales de Sodio/genética
8.
J Cardiovasc Electrophysiol ; 31(6): 1436-1447, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32227530

RESUMEN

INTRODUCTION: Accurate identification of slow conducting regions in patients with scar-related atrial tachycardia (AT) is difficult using conventional electrogram annotation for cardiac electroanatomic mapping (EAM). Estimating delays between neighboring mapping sites is a potential option for activation map computation. We describe our initial experience with CARTO 3 Coherent Mapping (Biosense Webster Inc,) in the ablation of complex ATs. METHODS: Twenty patients (58 ± 10 y/o, 15 males) with complex ATs were included. We created three-dimensional EAMs using CARTO 3 system with CONFIDENSE and a high-resolution mapping catheter (Biosense Webster Inc). Local activation time and coherent maps were used to aid in the identification of conduction isthmus (CI) and focal origin sites. System-defined slow or nonconducting zones and CI, defined by concealed entrainment (postpacing interval < 20 ms), CV < 0.3 m/s and local fractionated electrograms were evaluated. RESULTS: Twenty-six complex ATs were mapped (mean: 1.3 ± 0.7 maps/pt; 4 focal, 22 isthmus-dependent). Coherent mapping was better in identifying CI/breakout sites where ablation terminated the tachycardia (96.2% vs 69.2%; P = .010) and identified significantly more CI (mean/chamber 2.0 ± 1.1 vs 1.0 ± 0.7; P < .001) with narrower width (19.8 ± 10.5 vs 43.0 ± 23.9 mm; P < .001) than conventional mapping. Ablation at origin and CI sites was successful in 25 (96.2%) with long-term recurrence in 25%. CONCLUSIONS: Coherent mapping with conduction velocity vectors derived from adjacent mapping sites significantly improved the identification of CI sites in scar-related ATs with isthmus-dependent re-entry better than conventional mapping. It may be used in conjunction with conventional mapping strategies to facilitate recognition of slow conduction areas and critical sites that are important targets of ablation.


Asunto(s)
Potenciales de Acción , Cicatriz/complicaciones , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Taquicardia Supraventricular/diagnóstico , Anciano , Algoritmos , Ablación por Catéter , Cicatriz/diagnóstico , Femenino , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/cirugía , Factores de Tiempo , Resultado del Tratamiento
9.
Pacing Clin Electrophysiol ; 42(2): 216-223, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30536679

RESUMEN

INTRODUCTION: Adjunctive driver-guided ablation in addition to pulmonary vein isolation has been proposed as a strategy to improve procedural success and outcomes for various populations with atrial fibrillation (AF). First, this study aimed to evaluate the different mapping techniques for driver/rotor identification and second to evaluate the benefits of driver/rotor-guided ablation in patients with paroxysmal and persistent AF (PerAF). METHODS: We searched the electronic database in PubMed using the keywords "atrial fibrillation," "rotor," "rotational driver," "atrial fibrillation source," and "drivers" for both randomized controlled trials and observational controlled trials. Clinical studies reporting efficacy or safety outcomes of driver-guided ablation for paroxysmal AF or (PerAF) were identified. We performed subgroup analyses comparing different driver mapping methods in patients with PerAF. The odds ratios (ORs) with random effects were analyzed. RESULTS: Out of 175 published articles, seven met the inclusion criteria, of which two were randomized controlled trials, one was quasiexperimental study, and four observational studies (three case-controlled studies and one cross-sectional study). Overall, adjunctive driver-guided ablation was associated with higher rates of acute AF termination (OR: 4.62, 95% confidence interval [CI]: 2.12-10.08; P < 0.001), lower recurrence of any atrial arrhythmia (OR: 0.44, 95% CI: 0.30-0.065; P < 0.001), and comparable complication incidence. CONCLUSIONS: Adjunctive driver-guided catheter ablation suggested an increased freedom from AF/AT relative to conventional strategies, irrespective of the mapping techniques. Furthermore, phase mapping appears to be superior to electrogram-based driver mapping in PerAF ablation.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Humanos , Estudios Observacionales como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto
10.
Int J Cardiol ; 272: 90-96, 2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-30173923

RESUMEN

BACKGROUND: Intracardiac electrogram recording is influenced by the electrode size and inter-electrode spacing. Smaller electrodes with a closer inter-electrode spacing may improve the mapping resolution and outcome. METHODS: Substrate mapping of the left atrium and residual pulmonary vein (PV) potentials during sinus rhythm was sequentially performed using a 3.5-mm electrode tip catheter and a 1-mm electrode multielectrode catheter in 33 patients (Group 1) that underwent repeat atrial fibrillation (AF) procedures. PV gap identification and electrophysiological characteristics were compared. Arrhythmia freedom was compared with a propensity matched (1:2) control group (66 patients, Group 2) undergoing repeat AF procedures guided by wide inter-electrode spacing catheter. RESULTS: In the Group 1 patients, the total area of residual PV potentials measured using the 1-mm catheter was larger than that measured by the 3.5-mm catheter. Overall 1.97 ±â€¯0.59 (1-3) and 1.49 ±â€¯0.62 (1-3) PVs were identified by the 1-mm electrode and 3.5 mm catheters, respectively (P = 0.02). The gaps not identified by the 3.5 mm catheter had a smaller width and lower voltage. Radiofrequency catheter ablation in the areas with residual PV potentials identified by the 1-mm catheter resulted in complete electrical isolation of the PVs. Arrhythmia freedom at one year of follow-up was achieved in 26 of 33 (78.8%) patients in Group 1, which was significantly higher than the matched control group (33/66 [50%], P < 0.05). CONCLUSION: In the patients with a previous PV isolation, mapping with small, closely spaced electrodes can increase the detection rate of residual PV potentials and improve the outcome.


Asunto(s)
Ablación por Catéter/instrumentación , Electrocardiografía/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Angiografía por Tomografía Computarizada/instrumentación , Angiografía por Tomografía Computarizada/métodos , Electrocardiografía/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Femenino , Humanos , Masculino , Microelectrodos , Persona de Mediana Edad , Estudios Prospectivos
11.
J Cardiovasc Electrophysiol ; 29(5): 699-706, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29424013

RESUMEN

INTRODUCTION: Cigarette smoking contributes to the development of atrial fibrosis via nicotine. The impact of smoking on ablation results in persistent atrial fibrillation (AF) is unknown. We aimed to investigate the triggers and long-term outcome between smokers and nonsmokers in the patients with persistent AF after catheter ablation. METHODS: This study included 201 (177 males, 53 ± 10 years old) patients who received index catheter ablation, including pulmonary vein isolation (PVI) and complex fractionated atrial electrograms (CFAEs) ablation for persistent AF, retrospectively. Electrophysiological characteristics at the index procedure and long-term outcome were investigated to determine the differences between smokers and nonsmokers. RESULTS: Baseline characteristics were similar between two groups. Pulmonary vein (PV) triggers were found in all patients in the two groups. There was a higher incidence of nonpulmonary vein (NPV) triggers in smokers than in nonsmokers (61% vs. 31%, P < 0.05). There were no differences of the long-term ablation outcomes between smokers and nonsmokers in Kaplan-Meier analysis. Smokers with PV plus right atrial NPV (RA-NPV) triggers had a higher incidence of recurrence (log-rank P < 0.05) than those without RA-NPV triggers, but not in nonsmokers, after a mean follow-up of 31 ± 25 months. CONCLUSIONS: Smoking increases the incidence of NPV triggers in patients with persistent AF. Smokers who have RA-NPV triggers during index procedure do have a worse outcome after catheter ablation, indicating the harmful effects of nicotine to right atrium.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Fumar/efectos adversos , Potenciales de Acción , Adulto , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Nicotina/efectos adversos , Agonistas Nicotínicos/efectos adversos , No Fumadores , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Fumadores , Fumar/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 29(2): 298-307, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29071756

RESUMEN

BACKGROUND: Septal ventricular outflow tract ventricular arrhythmias (OT-VAs) are defined as septal origin VAs from the right ventricular or left ventricular OT. Patients with septal OT-VAs may require a sequential bilateral OT ablation. This study aimed to evaluate the electrophysiological characteristics and ablation outcome in patients with septal OT-VAs. METHODS: We retrospectively analyzed the electrocardiography and electrophysiological parameters in 96 patients (mean age 49 ± 15 years, 49 male) undergoing bilateral activation mapping before catheter ablation of idiopathic septal OT-VAs. The patients were categorized into three groups based on the successful ablation sites, including the right ventricular outflow tract (RVOT), RVOT/left ventricular outflow tract (LVOT), and LVOT. RESULTS: Mapping in the three groups demonstrated a gradually decreasing and increasing trend in the earliest activation time obtained from the RVOT and LVOT, respectively. The absolute earliest activation time discrepancy (AEAD) of ≤18 milliseconds could predict the requirement for a sequential bilateral ablation with a sensitivity and specificity of 100.0% and 93.7%, respectively. The small AEAD (≤21 milliseconds) was associated with a higher recurrence rate in patients receiving a successful unilateral ablation, while patients with a longer distance between the bilateral OT earliest activation sites (DEA > 26 mm) increased future recurrences after an initially successful sequential bilateral ablation. CONCLUSIONS: The application of bilateral OT-VA activation mapping and the measurement of the AEAD and DEA provided not only pivotal information for the ablation strategy, but also prognostic implications for recurrences in patients with septal OT-VAs.


Asunto(s)
Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Taquicardia Ventricular/cirugía , Tabique Interventricular/cirugía , Potenciales de Acción , Adulto , Anciano , Ablación por Catéter/efectos adversos , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda , Función Ventricular Derecha , Tabique Interventricular/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA