Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Epilepsy Behav ; 88: 96-105, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30243112

RESUMEN

OBJECTIVE: Our previous study of monaural auditory evoked magnetic fields (AEFs) demonstrated that hippocampal sclerosis significantly modulated auditory processing in patients with mesial temporal lobe epilepsy (mTLE). However, the small sample size (n = 17) and focus on the M100 response were insufficient to elucidate the lateralization of the epileptic focus. Therefore, we increased the number of patients with mTLE (n = 39) to examine whether neural synchronization induced by monaural pure tone stimulation provides useful diagnostic information about epileptic foci in patients with unilateral mTLE. METHODS: Twenty-five patients with left mTLE, 14 patients with right mTLE, and 32 healthy controls (HCs) were recruited. Auditory stimuli of 500-Hz tone burst were monaurally presented to subjects. The AEF data were analyzed with source estimation of M100 responses in bilateral auditory cortices (ACs). Neural synchronization within ACs and between ACs was evaluated with phase-locking factor (PLF) and phase-locking value (PLV), respectively. Linear discriminant analysis was performed for diagnosis and lateralization of epileptic focus. RESULTS: The M100 amplitude revealed that patients with right mTLE exhibited smaller M100 amplitude than patients with left mTLE and HCs. Interestingly, PLF was able to differentiate the groups with mTLE, with decreased PLFs in the alpha band observed in patients with right mTLE compared with those (PLFs) in patients with left mTLE. Right hemispheric predominance was confirmed in both HCs and patients with left mTLE while patients with right mTLE showed a lack of right hemispheric predominance. Functional connectivity between bilateral ACs (PLV) was reduced in both patients with right and left mTLE compared with that of HCs. The accuracy of diagnosis and lateralization was 80%-90%. CONCLUSION: Auditory cortex subnormal function was more pronounced in patients with right mTLE compared with that in patients with left mTLE as well as HCs. Monaural AEFs can be used to reveal the pathophysiology of mTLE. Overall, our results indicate that altered neural synchronization may provide useful information about possible functional deterioration in patients with unilateral mTLE.


Asunto(s)
Estimulación Acústica , Corteza Auditiva/fisiopatología , Sincronización Cortical , Epilepsia del Lóbulo Temporal/fisiopatología , Potenciales Evocados Auditivos , Adulto , Anciano , Corteza Auditiva/diagnóstico por imagen , Estudios de Casos y Controles , Epilepsia del Lóbulo Temporal/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad
2.
Neuroimage ; 124(Pt A): 256-266, 2016 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-26363346

RESUMEN

The hippocampus is well known to be involved in memory, as well as in perceptual processing. To date, the electrophysiological process by which unilateral hippocampal lesions, such as hippocampal sclerosis (HS), modulate the auditory processing remains unknown. Auditory-evoked magnetic fields (AEFs) are valuable for evaluating auditory functions, because M100, a major component of AEFs, originates from auditory areas. Therefore, AEFs of mesial temporal lobe epilepsy (mTLE, n=17) with unilateral HS were compared with those of healthy (HC, n=17) and disease controls (n=9), thereby determining whether AEFs were indicative of hippocampal influences on the auditory processing. Monaural tone-burst stimuli were presented for each side, followed by analysis of M100 and a previously less characterized exogenous component (M400: 300-500ms). The frequency of acceptable M100 dipoles was significantly decreased in the HS side. Beam-forming-based source localization analysis also showed decreased activity of the auditory area, which corresponded to the inadequately estimated dipoles. M400 was found to be related to the medial temporal structure on the HS side. Volumetric analysis was also performed, focusing on the auditory-related areas (planum temporale, Heschl's gyrus, and superior temporal gyrus), as well as the hippocampus. M100 amplitudes positively correlated with hippocampal and planum temporale volumes in the HC group, whereas they negatively correlated with Heschl's gyrus volume in the mTLE group. Interestingly, significantly enhanced M400 component was observed in the HS side of the mTLE patients. In addition, the M400 component positively correlated with Heschl's gyrus volume and tended to positively correlate with disease duration. M400 was markedly diminished after hippocampal resection. Although volumetric analysis showed decreased hippocampal volume in the HS side, the planum temporale and Heschl's gyrus, the two major sources of M100, were preserved. These results suggested that HS significantly influenced AEFs. Therefore, we concluded that the hippocampus modulates auditory processing differently under normal conditions and in HS.


Asunto(s)
Corteza Auditiva/fisiopatología , Percepción Auditiva/fisiología , Epilepsia del Lóbulo Temporal/fisiopatología , Hipocampo/fisiopatología , Estimulación Acústica , Adulto , Anciano , Epilepsia del Lóbulo Temporal/patología , Epilepsia del Lóbulo Temporal/cirugía , Potenciales Evocados Auditivos , Femenino , Lateralidad Funcional/fisiología , Hipocampo/patología , Hipocampo/cirugía , Humanos , Imagen por Resonancia Magnética , Magnetoencefalografía , Masculino , Persona de Mediana Edad , Esclerosis , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA