Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Métodos Terapéuticos y Terapias MTCI
Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Environ Sci Pollut Res Int ; 30(51): 111611-111626, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37819473

RESUMEN

The excessive presence of phosphate can cause eutrophication in water bodies. Yttrium has an extremely high affinity for phosphorus and is capable of forming stable complexes at low concentrations. Moreover, limitations in the resourcefulness of drinking water treatment residues were observed. In this study, a highly efficient phosphorus removal adsorbent (RJDWTR@Y) was prepared by calcination-alkali leaching-yttrium-loaded composite modification employing domestic drinking water treatment residue as raw material. And the effects of multiple factors on phosphate adsorption by RJDWTR@Y were examined. The results illustrated that the maximum adsorption capacity of the RJDWTR@Y for phosphate was 319.76 mg/g, with the chemical reaction of the multilayer as the predominant adsorption process. The adsorption mechanism is electrostatic gravitational force and the inner sphere complexation effect. RJDWTR@Y was effective against interference even at high concentrations of the coexisting anion. After five cycles, the desorption efficiency of phosphate was 75.11%. Filling the fixed bed with the material can efficiently remove phosphorus from the flowing liquid. The synthesis of RJDWTR@Y and the results of the study indicated that it has good application prospects. In addition to efficiently removing phosphorus, it can also recycle waste and achieve sustainability.


Asunto(s)
Agua Potable , Contaminantes Químicos del Agua , Fósforo/química , Itrio , Reproducibilidad de los Resultados , Aguas Residuales , Cinética , Fosfatos/química , Adsorción , Contaminantes Químicos del Agua/química , Concentración de Iones de Hidrógeno
2.
Artículo en Chino | MEDLINE | ID: mdl-34672462

RESUMEN

Objective: On the basis of preliminarily verifying the use of ultra-fast reaction polymer matrix optical fiber oxygen sensor and its measuring system to record the continuous and dynamic changes of carotid artery oxygen partial pressure (PaO2), in order to analyze and discuss the influence of lung ventilation on the continuous and dynamic changes of PaO2, we designed a whole animal experimental study in vivo. Methods: Four hybrid goats were selected, and the skin was cut and exposed directly under general anesthesia and tracheal intubation. The oxygen sensor, connected with the measuring system, was inserted directly into the left carotid artery to continuously record the dynamic changes of PaO2. With normal minute ventilation,mechanical ventilation is implemented through three tidal volumes: normal tidal volume (VT=15 ml/kg, Rf=20 bpm), half tidal volume (halved VT, doubled Rf) and double tidal volume (doubled VT, halved Rf). Each tidal volume was stable for 10~15 min respectively. We analyzed and calculated the average values of PaO2, the fluctuation magnitudes of PaO2 changes between breaths of last 180 s and the delay times of lung-carotid artery were. We analyzed the effects of different tidal volumes. Results: The heart rate and blood pressure of living goats were maintained stable during the mechanical ventilation experiment with normal ventilation volume Lung-carotid artery delay time is 1.4~1.8 s (about 3 heartbeats at this time). Under normal tidal volume of mechanical ventilation, the average value of PaO2 was (102.94±2.40, 99.38~106.16) mmHg, and the fluctuation range was (21.43±1.65, 19.21~23.59) mmHg, accounting for (20.80± 1.34, 18.65~22.22)% of the average value. Under the condition of halving tidal volume, the average value of PaO2 was maintained at (101.01±4.25, 94.09~105.66) mmHg, which was slightly decreased but not significant (P>0.05 compared with normal mechanical ventilation), but the fluctuation range of PaO2 was significantly reduced to (18.14±1.43, 16.46~20.05) mmHg, accounting for 17.5% of the average value. Under double tidal volume mechanical ventilation, although the average value of PaO2 increased slightly remained at (106.42±4.74, 101.19~114.08) mmHg (P>0.05 compared with normal mechanical ventilation and P<0.05 compared with half tidal volume mechanical ventilation), the fluctuation magnitude of PaO2 increased significantly to (26.58±1.88, 23.46~28.46)mmHg. Conclusion: Inspiration and expiration of normal lung ventilation are the initial factors for the increase and decrease of PaO2 in carotid artery. Under normal ventilation, halving tidal volume and doubling tidal volume significantly changed the fluctuation magnitude of PaO2, but the average value of PaO2 changed only slightly, while the lung-carotid delay time was similar.


Asunto(s)
Cabras , Oxígeno , Animales , Arterias Carótidas , Respiración Artificial , Volumen de Ventilación Pulmonar
3.
Zhongguo Ying Yong Sheng Li Xue Za Zhi ; 37(1): 104-112, 2021 Jan.
Artículo en Chino | MEDLINE | ID: mdl-34672470

RESUMEN

Objective: We tried to implant the ultra-fast polymer optical fiber chemical oxygen sensor (POFCOS) into arterial blood vessel,connect with photoelectric conversion measurement system to record the continuous dynamic rapid changes of arterial PO2(PaO2) in whole living animals. It should be the experimental evidence for the new theory of holistic integrative physiology and medicine(HIPM) forexplain the mechanism of respiratory control and regulation in whole circusof respiration-circulation-metabolism. Methods: ①Fabrication of ultrafast POFCOS, calibration and its measuring system: The distal part of 2 m optical fiber was heated and pulled until it became a tapered tip. After cleaning and drying, the tip of 1 mm tapered optical fiber was dip-coated into the luminophore doped polymer solution, then was slowly pumped out while solvent was quickly evaporated to form an oxygen sensing tip, which was dried at room temperature for 24 hours. ②Animal experiments: Under general anesthesia and intubation, goatwas mechanically ventilated with 40%~60% oxygen. We exposed both right and left carotid arteries and the left femoral artery by skin cutting, and inserted the POFCOS directly into the arteries via indwelling catheter. The end of POFCOS were connected to the personal computer through optical fiber, excitation and detection Y-type optical fiber coupler through photoelectric conversion, so as we can realize the continuous dynamic response of living goat carotid PaO2 under mechanical ventilation. We mainly analyzed the intra-breath wave-form alternate increase and decrease of PaO2 and their time delay between lung and carotid arteries.We completes breathing control whole loop to explain the mechanism of mutual breathing and the switching of inspiration and exhalation. Results: The POFCOS has a very fast T90 response time was set 100 ms for liquid. When the heart rate of 40%~60% oxygen mechanical ventilated living goat was ~110 bpm, the PaO2 of left and right carotid artery showed a same wave-sizeup and down following with the inspiration and expiration of ventilator, with a range of up to 15 mmHg. There weresignificant noises of PaO2 change recorded in the left femoral artery. The lung-carotid artery time delay is 1.5~1.7 s after inhalation and exhalation, PaO2 at both left and right carotid arteries starts toincrease and decrease. After two-three heartbeats after the start of lung ventilation, thealternate up-down wave-form information of the arterialized pulmonary vein blood after pulmonary capillaries waspumpedby left ventricle to the position of peripheral chemoreceptors,thus realizing the whole cycle of inhalation and exhalation. It alternately interrupted inhalation, i.e. switching inhalation to exhalation, and then interrupted exhalation,i.e. switching exhalation to inhalation. Conclusion: The ultra-fast reactive implantableoxygen sensor and its measuring system can measure the physiological waveform changes of PaO2 in living animals, which can provide experimental evidence for explaining the mechanism of switching of inspiration-expiration in HIPM.


Asunto(s)
Polímeros , Respiración Artificial , Animales , Fibras Ópticas , Oxígeno , Presión Parcial
4.
J Ethnopharmacol ; 214: 106-112, 2018 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-29253616

RESUMEN

ETHNOPHARMACOLOGICAL RELEVANCE: Cordyceps sinensis is a traditional Chinese medicine and has been used as adjuvant treatments for cancer and it has been also demonstrated to be effective in cancer patients. AIM OF THE STUDY: The objective of the present study is to investigate the anti-metastasis effects of water extracts of Cordyceps sinensis (WECS) in breast cancer and the potential mechanisms. MATERIALS AND METHODS: The cytotoxicity of WECS on 4T1 breast cancer cells was evaluated in vitro using cell counting kit-8 (CCK8) assay. The in vivo anti-metastatic activity of intraperitoneally administered WECS and its effect on animal survival were measured in a mouse breast cancer metastasis model. To explore the molecular mechanisms of the anti-metastasis effect of WECS, the expression of matrix metalloprotein-9 (MMP-9) in serum was determined by enzyme-linked immunosorbent assay (ELISA). In addition, a protein array was used to examine the cytokine expression profiles in lung homogenates. RESULTS: Treatment with WECS (0.10-0.40mg/ml) significantly inhibited 4T1 cell viability in vitro. In animal studies, 50mg/kg WECS significantly reduced the number of metastatic lung nodules and the weight of lung, without affecting body weight of mice. Furthermore, WECS increased the survival rate of 4T1 tumor bearing mice in a dose dependent manner, and at high dose, WECS (50mg/kg) significantly increased the life span of the mice compared to untreated control group. The expression level of MMP-9 in serum was decreased about 50% in 50mg/kg WECS treated group compared to control group. The results of protein array showed that the expression of CC chemokine ligand 17 (CCL17), MMP-9, osteopontin (OPN), interleukin-33 (IL-33), CC chemokine ligand 12 (CCL12) and CC chemokine ligand 6 (CCL6) in the lungs of 4T1 tumor bearing mice was increased more than two fold compared with normal mice. Among them, the expression of CCL17, MMP-9, OPN, IL-33 was significantly reduced by treatment of 50mg/kg WECS. CONCLUSION: Our results demonstrated that WECS has potent anti-metastasis activity in a mouse breast cancer metastasis model possibly by down-regulation the expression of several metastasis-related cytokines.


Asunto(s)
Antineoplásicos Fitogénicos/farmacología , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias Pulmonares/prevención & control , Extractos Vegetales/farmacología , Animales , Antineoplásicos Fitogénicos/aislamiento & purificación , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/patología , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Cordyceps/química , Citocinas/genética , Relación Dosis-Respuesta a Droga , Regulación hacia Abajo , Femenino , Regulación Neoplásica de la Expresión Génica , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/secundario , Metaloproteinasa 9 de la Matriz/metabolismo , Ratones , Ratones Endogámicos BALB C , Osteopontina/metabolismo , Fitoterapia , Extractos Vegetales/aislamiento & purificación , Plantas Medicinales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA