Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Métodos Terapéuticos y Terapias MTCI
Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Manipulative Physiol Ther ; 23(6): 380-94, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10951308

RESUMEN

OBJECTIVE: To test the a priori hypothesis that one of the positive mechanisms of action of chiropractic side-posture manipulation (adjusting) of the lumbar spine is to separate, or gap, the zygapophysial (Z) joints. DESIGN: Before and after study with randomization. SETTING: Chiropractic college clinic and magnetic resonance imaging (MRI) facility. PARTICIPANTS: Sixteen healthy student volunteers (8 men and 8 women) ages 22 to 29 years with no history of significant low back pain. Nineteen volunteers were screened, with 3 disqualified from the study. Subjects were randomized into 4 groups, each with 2 men and 2 women. INTERVENTIONS: Lumbar side-posture spinal adjusting (manipulation) and side-posture positioning. MAIN OUTCOME MEASURES: Comparison of anterior to posterior measurements of the Z joints from MRI scans taken before and after side-posture spinal adjusting and before and after side-posture positioning, and a rigorous subjective evaluation protocol of the Z joints by 3 radiologists blinded to the randomized groups. MAIN RESULTS: Observers making measurements were blinded to what group subjects were placed in and whether they were measuring first or second scans; radiologists were blinded to what group subjects were assigned. Differences were found between the groups. Those receiving side-posture spinal adjusting and remaining in side posture showed the greatest increase in gapping (0.7 mm vs 0.0 mm for controls). CONCLUSIONS: Lumbar side-posture spinal adjusting produced increased separation (gapping) of the zygapophysial joints. Side-posture positioning also produced gapping, but less than that seen with lumbar side-posture adjusting. A larger clinical trial should be performed to further define the results of this study.


Asunto(s)
Articulaciones/anatomía & histología , Vértebras Lumbares/anatomía & histología , Imagen por Resonancia Magnética , Postura , Adulto , Femenino , Humanos , Masculino , Variaciones Dependientes del Observador , Rango del Movimiento Articular , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Columna Vertebral/anatomía & histología
2.
Chiropr Hist ; 18(2): 13-24, 1998 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11623679

RESUMEN

The intervertebral foramina (IVFs) are important to all individuals who treat disorders of the spine, but this region is of special historic significance to chiropractors. This is because some of the earliest descriptions of the mechanism of action of chiropratic were related to the IVFs. The history of investigation of the IVFs is very rich spanning time from the fifth century B.C. to the present. Several professions were based upon theories related to the IVFs or upon serious investigations of the IVFs, and the results of other investigations were reported out of proper context in order to criticize chiropractic and other professions. The history of investigation of the IVFs can be divided into three time periods: 1) very early descriptions of neural foramina and the IVFs; )2 discussions of IVFs by developing professions and the studies of the IVFs by Swanberg in the early twentieth century; and 3) studies of the IVFs in the middle and late twentieth century. This paper discusses the major activities of each of these time periods.


Asunto(s)
Quiropráctica/historia , Disco Intervertebral , Historia del Siglo XIX , Historia del Siglo XX , Historia Moderna 1601- , Columna Vertebral , Estados Unidos
3.
J Manipulative Physiol Ther ; 20(3): 150-68, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9127254

RESUMEN

A position paper was prepared as background information for participants in the National Workshop to Develop the Chiropractic Workshop Agenda conducted by the Palmer Center for Chiropractic Research, Davenport, Iowa. The paper was revised in light of comments and suggestions at the workshop by participants and by a workgroup composed of basic scientists from within and outside of chiropractic. This final article documents the history of basic science research in chiropractic, and the current state of the art of basic science research conducted since 1975 by chiropractors or investigators at chiropractic institutions in North America. Seed recommendations contained in the working paper for the development of an adequate infrastructure needed to conduct future research and seed recommendations for a future basic science research agenda were also modified and revised by the workgroup participants through a modified nominal group process. The final recommendations contained in this article represent a synthesis of these recommendations and those of the authors.


Asunto(s)
Quiropráctica , Investigación , Columna Vertebral , Animales , Fenómenos Biomecánicos , Modelos Animales de Enfermedad , Humanos , Columna Vertebral/anatomía & histología , Columna Vertebral/fisiología
4.
J Manipulative Physiol Ther ; 18(4): 195-202, 1995 May.
Artículo en Inglés | MEDLINE | ID: mdl-7636408

RESUMEN

OBJECTIVE: To compare magnetic resonance imaging (MRI) scans obtained from 1.5 Tesla (T) MRI units with scans obtained from 0.35T MRI units in the morphometric evaluation of the lumbar intervertebral foramina (IVF). DESIGN: Three dimensions of lumbar IVFs were measured on a cadaveric lumbar spine by using Vernier calipers. The spine was embedded in gelatin to simulate soft tissue and scanned twice in a 1.5T MRI unit (3-mm and 5-mm slice thicknesses) and once in a 0.35T MRI unit (5-mm slice thickness). Measurements from the scans were made independently by three observers. The results obtained from the two units were compared to the actual IVF size (as measured by calipers) and to one another. RESULTS: The greatest superior-to-inferior distance had the strongest statistically significant correlation to the actual cadaver measurements for both the 0.35T and 1.5T imaging units [r = 0.986 (0.35T); r = 0.985 (1.5T at 3 mm) and r = 0.981 (1.5T at 5 mm); p < .0001 in all cases]. Mean differences and standard errors were minimal between measurements made from MRI scans of both 1.5T and 0.35T units and measurements made directly from the cadaveric spine. CONCLUSION: Both imaging units produced images that accurately depicted the actual size of the IVF. The MRI units of 0.35T field strength produced images of high morphometric accuracy. In addition, the potential for side effects and the operating costs are less with 0.35T units. Therefore, 0.35T MRI units may be a prudent choice as a clinical and research imaging tool in the evaluation of the lumbar IVF.


Asunto(s)
Vértebras Lumbares/anatomía & histología , Imagen por Resonancia Magnética/instrumentación , Humanos
5.
J Manipulative Physiol Ther ; 16(2): 67-73, 1993 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-8445356

RESUMEN

OBJECTIVE: To compare the reliability, validity and change in patient clinical status over time with treatment for six potential outcome questionnaires in a defined population of patients. SETTING: Physician based, multidoctor teaching practice. PATIENTS: Three hundred thirty-five consecutive patients presenting with new complaints were solicited. One hundred eighty-six agreed to participate. INTERVENTIONS: The six questionnaires being studied were administered to each of the participants on three separate occasions. They were: a) prior to clinical evaluation for their chief complaint, b) immediately after clinical evaluation and before treatment and c) 6 wk later. MEASUREMENTS: Each instrument was scored following the prescribed methods of interpretation from the original literature describing it. Results were submitted for analysis by Pearson correlation and two-way analysis of variance as appropriate. MAIN RESULTS: Differences were found in the mean value of the modified Zung with respect to both gender and time. An unexpected drop in patients' somatic perceptions in association with the process of clinical evaluation was found for the Modified Somatic Pain Questionnaire. Overall, the Oswestry and Visual Analogue Pain Scale were the most reliable and responsive to clinical change for musculoskeletal disorders. CONCLUSIONS: This investigation demonstrated substantial differences in the validity and reliability of commonly referenced self-administered instruments for quantifying patient perceptions of pain and disability. The Oswestry and Visual Analogue Pain Scale were both more reliable and valid than other instruments.


Asunto(s)
Dolor de Espalda/terapia , Evaluación de Resultado en la Atención de Salud , Dolor de Espalda/clasificación , Femenino , Humanos , Masculino , Dimensión del Dolor , Reproducibilidad de los Resultados , Encuestas y Cuestionarios
6.
J Manipulative Physiol Ther ; 16(1): 7-13, 1993 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8423429

RESUMEN

OBJECTIVE: To evaluate the use of the Hmax/Mmax (H/M) ratio as an outcome measure for acute low back pain and to determine the change of this ratio in acute low back pain patients treated with spinal manipulation. DESIGN: Randomized clinical trial. SETTING: Chiropractic college teaching clinic. PATIENTS: Thirty-six patients with acute low back pain (pain of less than 2 wk duration) were referred by clinicians of the teaching clinic. Eligibility criteria for inclusion into the study consisted of the following: a score of eight or more on the Oswestry questionnaire, 33 mm or greater on a 100-mm visual analog scale, no involvement in litigation related to the low back pain complaint, patient not pregnant and no physical or electrodiagnostic signs of nerve root entrapment. INTERVENTIONS: The patients were randomly assigned to either a treatment or control group. The treatment group (n = 17) received treatment deemed appropriate by the clinician as long as it included a side-lying manipulation to the appropriate level. The control group (n = 19) received detuned ultrasound, application of a cold pack and 15-30 sec of very gentle soft tissue massage. Patients were treated three to five times over a period of 10 days and were subsequently reevaluated. MEASUREMENTS: The Hmax/Mmax ratio was calculated from the results of electrodiagnostic testing of the posterior tibial nerve. Extension/flexion ratio of the trunk musculature, Oswestry score and Visual Analog Scale score were also measured. MAIN RESULTS: The mean difference between H/M ratios pre- and postintervention for the group treated by chiropractic methods was -0.101 on the left and -0.117 on the right. The mean difference for the control group was 0.038 on the left and 0.036 on the right. Although not statistically significant, trends suggest that at the time of final assessment, the group receiving chiropractic care had improved more than the control group. CONCLUSIONS: The H/M ratio was found to be within normal limits in subjects with acute low back pain. The H/M ratio showed greater change in the group which received spinal manipulation, but the change was subtle. The results indicate that the H/M ratio may be of limited value in clinical practice.


Asunto(s)
Quiropráctica/métodos , Reflejo H , Dolor de la Región Lumbar/terapia , Dimensión del Dolor/métodos , Adulto , Electromiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Conducción Nerviosa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA