1.
JACC Cardiovasc Interv ; 9(20): 2113-2120, 2016 10 24.
Artículo en Inglés | MEDLINE | ID: mdl-27765304

RESUMEN

OBJECTIVES: The study sought to assess the safety and efficacy of a minimally invasive strategy (MIS) (local anesthesia and conscious sedation) compared to general anesthesia (GA) among the largest published cohort of patients undergoing transcarotid transcatheter aortic valve replacement (TAVR). BACKGROUND: Transcarotid TAVR has been shown to be feasible and safe. There is, however, no information pertaining to the mode anesthesia in these procedures. METHODS: Between 2009 and 2014, 174 patients underwent transcarotid TAVR at 2 French centers. All patients were unsuitable for transfemoral TAVR due to severe peripheral vascular disease. An MIS was undertaken in 29.8% (n = 52) and GA in 70.1% (n = 122). One-year clinical outcomes were available in all patients and were described according to the Valve Academic Research Consortium-2 consensus. RESULTS: Transcarotid vascular access and transcatheter valve deployment was successful in all cases. Thirty-day mortality was 7.4% (n = 13) and 1-year all-cause and cardiovascular mortality were 12.6% (n = 22) and 8.0% (n = 14), respectively. According to the type of anesthesia, there was no between group difference in 30-day mortality (GA 7.3% vs. MIS 7.6%; p = 0.94), 1-year mortality (GA 13.9% vs. MIS 9.6%; p = 0.43), 1-month clinical efficacy (GA 85.2% vs. MIS 94.2%; p = 0.09), and early safety (GA 77.8% vs. MIS 86.5%; p = 0.18). There were 10 (5.7%) periprocedural cerebrovascular events: 4 strokes (2.2%) and 6 transient ischemic attacks (3.4%) among those treated with GA. There was neither stroke nor transient ischemic attack in the MIS group (p < 0.001). CONCLUSIONS: The transcarotid approach for TAVR is feasible using general or local anesthesia. A higher rate of perioperative strokes was observed with GA.


Asunto(s)
Anestesia General , Anestesia Local , Válvula Aórtica/cirugía , Arteria Carótida Común , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Anestesia General/efectos adversos , Anestesia General/mortalidad , Anestesia Local/efectos adversos , Anestesia Local/mortalidad , Bases de Datos Factuales , Femenino , Francia , Humanos , Ataque Isquémico Transitorio/etiología , Estimación de Kaplan-Meier , Masculino , Modelos de Riesgos Proporcionales , Punciones , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/etiología , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA