Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Arch Cardiovasc Dis ; 106(11): 562-9, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24200925

RESUMEN

BACKGROUND: Defibrillation testing (DT) is usually performed during implantable cardioverter defibrillator (ICD) implantation. AIMS: We conducted a multicentre prospective study to determine the DT procedures used in everyday practice, to compare the characteristics of patients with or without DT, and to compare severe adverse events in these two populations during implantation and follow-up. METHODS: The LEADER registry enrolled 904 patients included for primo-implantation of a single (n=261), dual (n=230) or triple (n=429) defibrillation system in 42 French centres. RESULTS: Baseline characteristics of patients (62.0 ± 13.5 years; 88% men; primary indication 62%) who underwent ventricular fibrillation (VF) induction (VF induction group, n=810) and those who did not (untested group, n=94, representing 10.4% of the entire study population) revealed that the untested group were older (P<0.01), had a lower left ventricular ejection fraction, a wider QRS complex and a higher New York Heart Association class and were more often implanted for primary prevention (P<0.001 for all). The main reason given for not performing ICD testing was poor haemodynamic condition (59/94). At 1 year, the cumulative survival rate was 95% in tested patients and 85% in untested patients (P<0.001), mainly because of heart failure deaths. There was one sudden cardiac death in the VF induction group and none in the untested group (P=1.000). CONCLUSIONS: In this study, more than 10% of ICD patients were implanted without VF induction. Untested patients appeared to be sicker than tested patients, with a more severe long-term outcome, but without any difference in mortality due to arrhythmic events.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Insuficiencia Cardíaca/terapia , Anciano , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Francia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Hemodinámica , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sistema de Registros , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/prevención & control , Función Ventricular Izquierda
2.
Eur Heart J ; 30(10): 1237-44, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19264750

RESUMEN

AIMS: The aim of this study was to investigate the 12-month incidence, predictive factors, and prognosis of sustained ventricular tachycardia (VT) in chronic heart failure patients implanted with biventricular pacemakers without a back-up defibrillator (CRT-P), assessed by continuous intracardiac ventricular electrograms. METHODS AND RESULTS: The Mona Lisa study, a prospective, multicentre, cohort study, designed to determine the incidence of sustained VT and its prognostic impact in CRT-P recipients within the year after implant enrolled 198 patients with moderate or severe chronic heart failure, despite optimal pharmacological therapy. An independent committee reviewed the data from all arrhythmic episodes as well as causes of death according to predefined criteria. During a mean follow-up of 9.8 +/- 3.1 months after implantation, 8 patients experienced at least one episode of sustained VT [4.3%; 95% confidence interval (CI), 1.1-7.5] and 21 deaths occurred, giving a 12-month mortality rate of 11.7% (95% CI, 6.4-16.9). The presence of sustained VT was associated with a high risk of sudden cardiac death (SCD) and the lowest 12-month overall survival (P < 0.0001). CONCLUSION: The incidence of sustained VT remains relatively low in the first year after CRT-P implantation, but when present appears closely associated with short-term adverse outcomes, especially SCD. This emphasizes the possible value of remote monitoring to detect high-risk patients for urgent upgrading.


Asunto(s)
Muerte Súbita Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Marcapaso Artificial , Taquicardia Ventricular/epidemiología , Anciano , Anciano de 80 o más Años , Estimulación Cardíaca Artificial/efectos adversos , Causas de Muerte , Técnicas Electrofisiológicas Cardíacas/métodos , Métodos Epidemiológicos , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/mortalidad
SELECCIÓN DE REFERENCIAS