Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Cardiovasc Electrophysiol ; 31(12): 3106-3114, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32955151

RESUMEN

INTRODUCTION: The need for transparency in financial relationships in the healthcare system, has culminated in Open Payments database, managed by the Center for Medicare and Medicaid Services (CMS). Since its inception in 2013, the trend in such payments to physicians practicing cardiac electrophysiology was not examined. METHODS AND RESULTS: Payment information reported to CMS from January 2013 to December 2018 was obtained from the publicly available Open Payments data set using the online query tool. The data were analyzed by an individual provider and by state. An in-depth analysis of payments in the year 2018 payments was performed. From 2014 to 2018, there was an 18% increase in the total number of payments reported from 88 877 payments in 2014 to 105 000 in 2018. Despite the increase in the total number of payments reported, the average payment steadily decreased over time, resulting in an overall reduction in the total amount of payments from 2014 to 2018 ($34.9 million to $28.2 million). Payments to the top 5% of individual recipients have also decreased over this time. In 2018, 2888 unique providers received reportable payments, a total of 105 000 payments, with a median payment amount of $1378 (interquartile range: $165-$5781). The majority of these payments were for food and beverage (82%) and travel/lodging (10%). The top five payers include Boston Scientific, Medtronic Vascular, Abbott Laboratories, Janssen Pharmaceuticals, and Biotronik. CONCLUSION: Among cardiac electrophysiologists, there is increased reporting of payments in the Open Payments program over time, with a notable decrease in the payment amount.


Asunto(s)
Conflicto de Intereses , Médicos , Anciano , Boston , Técnicas Electrofisiológicas Cardíacas , Humanos , Medicare , Estados Unidos
2.
J Am Heart Assoc ; 9(11): e016598, 2020 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-32427020

RESUMEN

The primary goal of the initial ECG evaluation of every wide complex tachycardia is to determine whether the tachyarrhythmia has a ventricular or supraventricular origin. The answer to this question drives immediate patient care decisions, ensuing clinical workup, and long-term management strategies. Thus, the importance of arriving at the correct diagnosis cannot be understated and has naturally spurred rigorous research, which has brought forth an ever-expanding abundance of manually applied and automated methods to differentiate wide complex tachycardias. In this review, we provide an in-depth analysis of traditional and more contemporary methods to differentiate ventricular tachycardia and supraventricular wide complex tachycardia. In doing so, we: (1) review hallmark wide complex tachycardia differentiation criteria, (2) examine the conceptual and structural design of standard wide complex tachycardia differentiation methods, (3) discuss practical limitations of manually applied ECG interpretation approaches, and (4) highlight recently formulated methods designed to differentiate ventricular tachycardia and supraventricular wide complex tachycardia automatically.


Asunto(s)
Potenciales de Acción , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Animales , Diagnóstico Diferencial , Humanos , Valor Predictivo de las Pruebas , Taquicardia Supraventricular/fisiopatología , Taquicardia Ventricular/fisiopatología , Factores de Tiempo
3.
J Cardiovasc Electrophysiol ; 31(4): 952-959, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32048387

RESUMEN

INTRODUCTION: The ablation of outflow tract premature ventricular contractions (PVCs) is generally safe and effective. In some patients, successful ablation sites may not correlate with the earliest activation. We sought to evaluate mechanistic and anatomic relevance of the region below the left sinus of Valsalva in variable morphology outflow tract ventricular arrhythmias. METHODS: PVC cases where ablation was in the region inferior to the left sinus of Valsalva were identified. Procedural and demographic information and long-term outcomes were obtained. Cadaver dissections to evaluate regional anatomy were done as well. RESULTS: A total of 51 cases were included (age 53 ± 10; 37 [73%] males). Ablation was done for high PVC burden (>20%; mean 27% ± 8%) and presence of symptoms (73%) or ejection fraction less than 50% (78%). QRS morphology included either R wave (8; 16%), Rs (9; 18%), or rS (67%) in lead I, no precordial transition (40; 78%), V2 transition, (7; 14%), or V3 transition (4; 8%). In 31 (61%), the site just below the left coronary cusp was the earliest site, while the remainder had another site earlier. Ablation was acutely successful in 50 of 51 (98%). After 3 months, success was noted in 48 of 51 (94%). In two patients, repeat ablation in the same region resulted in durable suppression. CONCLUSION: The cases presented emphasize the importance of a region centered below the left sinus of Valsalva, where multivariable morphology QRS may be successfully ablated. Consideration of mapping and ablation even when signals are late in this region may be warranted in previously failed ablation attempts or first-line evaluation.


Asunto(s)
Potenciales de Acción , Ablación por Catéter , Frecuencia Cardíaca , Seno Aórtico/cirugía , Complejos Prematuros Ventriculares/cirugía , Adulto , Ablación por Catéter/efectos adversos , Electrocardiografía Ambulatoria , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Reoperación , Estudios Retrospectivos , Seno Aórtico/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/fisiopatología
4.
J Am Coll Cardiol ; 72(14): 1653-1676, 2018 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-29097297

RESUMEN

BACKGROUND: Although large randomized clinical trials have found that primary prevention use of an implantable cardioverter-defibrillator (ICD) improves survival in patients with cardiomyopathy and heart failure symptoms, patients who receive ICDs in practice are often older and have more comorbidities than patients who were enrolled in the clinical trials. In addition, there is a debate among clinicians on the usefulness of electrophysiological study for risk stratification of asymptomatic patients with Brugada syndrome. AIM: Our analysis has 2 objectives. First, to evaluate whether ventricular arrhythmias (VAs) induced with programmed electrostimulation in asymptomatic patients with Brugada syndrome identify a higher risk group that may require additional testing or therapies. Second, to evaluate whether implantation of an ICD is associated with a clinical benefit in older patients and patients with comorbidities who would otherwise benefit on the basis of left ventricular ejection fraction and heart failure symptoms. METHODS: Traditional statistical approaches were used to address 1) whether programmed ventricular stimulation identifies a higher-risk group in asymptomatic patients with Brugada syndrome and 2) whether ICD implantation for primary prevention is associated with improved outcomes in older patients (>75 years of age) and patients with significant comorbidities who would otherwise meet criteria for ICD implantation on the basis of symptoms or left ventricular function. RESULTS: Evidence from 6 studies of 1138 asymptomatic patients were identified. Brugada syndrome with inducible VA on electrophysiological study was identified in 390 (34.3%) patients. To minimize patient overlap, the primary analysis used 5 of the 6 studies and found an odds ratio of 2.3 (95% CI: 0.63-8.66; p=0.2) for major arrhythmic events (sustained VAs, sudden cardiac death, or appropriate ICD therapy) in asymptomatic patients with Brugada syndrome and inducible VA on electrophysiological study versus those without inducible VA. Ten studies were reviewed that evaluated ICD use in older patients and 4 studies that evaluated unique patient populations were identified. In our analysis, ICD implantation was associated with improved survival (overall hazard ratio: 0.75; 95% confidence interval: 0.67-0.83; p<0.001). Ten studies were identified that evaluated ICD use in patients with various comorbidities including renal disease, chronic obstructive pulmonary disease, atrial fibrillation, heart disease, and others. A random effects model demonstrated that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.72; 95% confidence interval: 0.65-0.79; p<0.0001), and a second "minimal overlap" analysis also found that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.61-0.82; p<0.0001). In 5 studies that included data on renal dysfunction, ICD implantation was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.60-0.85; p<0.001).


Asunto(s)
Arritmias Cardíacas/complicaciones , Muerte Súbita Cardíaca/prevención & control , Guías de Práctica Clínica como Asunto , American Heart Association , Arritmias Cardíacas/terapia , Enfermedades Asintomáticas , Síndrome de Brugada/diagnóstico , Comorbilidad , Muerte Súbita Cardíaca/etiología , Desfibriladores Implantables , Electrocardiografía , Humanos , Prevención Primaria , Estados Unidos
5.
Heart Rhythm ; 15(10): e253-e274, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29097318

RESUMEN

BACKGROUND: Although large randomized clinical trials have found that primary prevention use of an implantable cardioverter-defibrillator (ICD) improves survival in patients with cardiomyopathy and heart failure symptoms, patients who receive ICDs in practice are often older and have more comorbidities than patients who were enrolled in the clinical trials. In addition, there is a debate among clinicians on the usefulness of electrophysiological study for risk stratification of asymptomatic patients with Brugada syndrome. AIM: Our analysis has 2 objectives. First, to evaluate whether ventricular arrhythmias (VAs) induced with programmed electrostimulation in asymptomatic patients with Brugada syndrome identify a higher risk group that may require additional testing or therapies. Second, to evaluate whether implantation of an ICD is associated with a clinical benefit in older patients and patients with comorbidities who would otherwise benefit on the basis of left ventricular ejection fraction and heart failure symptoms. METHODS: Traditional statistical approaches were used to address 1) whether programmed ventricular stimulation identifies a higher-risk group in asymptomatic patients with Brugada syndrome and 2) whether ICD implantation for primary prevention is associated with improved outcomes in older patients (>75 years of age) and patients with significant comorbidities who would otherwise meet criteria for ICD implantation on the basis of symptoms or left ventricular function. RESULTS: Evidence from 6 studies of 1138 asymptomatic patients were identified. Brugada syndrome with inducible VA on electrophysiological study was identified in 390 (34.3%) patients. To minimize patient overlap, the primary analysis used 5 of the 6 studies and found an odds ratio of 2.3 (95% CI: 0.63-8.66; p=0.2) for major arrhythmic events (sustained VAs, sudden cardiac death, or appropriate ICD therapy) in asymptomatic patients with Brugada syndrome and inducible VA on electrophysiological study versus those without inducible VA. Ten studies were reviewed that evaluated ICD use in older patients and 4 studies that evaluated unique patient populations were identified. In our analysis, ICD implantation was associated with improved survival (overall hazard ratio: 0.75; 95% confidence interval: 0.67-0.83; p<0.001). Ten studies were identified that evaluated ICD use in patients with various comorbidities including renal disease, chronic obstructive pulmonary disease, atrial fibrillation, heart disease, and others. A random effects model demonstrated that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.72; 95% confidence interval: 0.65-0.79; p<0.0001), and a second "minimal overlap" analysis also found that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.61-0.82; p<0.0001). In 5 studies that included data on renal dysfunction, ICD implantation was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.60-0.85; p<0.001).


Asunto(s)
American Heart Association , Cardiología/normas , Muerte Súbita Cardíaca/prevención & control , Guías de Práctica Clínica como Asunto , Prevención Primaria/normas , Sociedades Médicas , Taquicardia Ventricular/terapia , Comités Consultivos , Muerte Súbita Cardíaca/etiología , Manejo de la Enfermedad , Humanos , Taquicardia Ventricular/complicaciones , Estados Unidos
6.
Circulation ; 138(13): e392-e414, 2018 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-29084732

RESUMEN

BACKGROUND: Although large randomized clinical trials have found that primary prevention use of an implantable cardioverter-defibrillator (ICD) improves survival in patients with cardiomyopathy and heart failure symptoms, patients who receive ICDs in practice are often older and have more comorbidities than patients who were enrolled in the clinical trials. In addition, there is a debate among clinicians on the usefulness of electrophysiological study for risk stratification of asymptomatic patients with Brugada syndrome. AIM: Our analysis has 2 objectives. First, to evaluate whether ventricular arrhythmias (VAs) induced with programmed electrostimulation in asymptomatic patients with Brugada syndrome identify a higher risk group that may require additional testing or therapies. Second, to evaluate whether implantation of an ICD is associated with a clinical benefit in older patients and patients with comorbidities who would otherwise benefit on the basis of left ventricular ejection fraction and heart failure symptoms. METHODS: Traditional statistical approaches were used to address 1) whether programmed ventricular stimulation identifies a higher-risk group in asymptomatic patients with Brugada syndrome and 2) whether ICD implantation for primary prevention is associated with improved outcomes in older patients (>75 years of age) and patients with significant comorbidities who would otherwise meet criteria for ICD implantation on the basis of symptoms or left ventricular function. RESULTS: Evidence from 6 studies of 1138 asymptomatic patients were identified. Brugada syndrome with inducible VA on electrophysiological study was identified in 390 (34.3%) patients. To minimize patient overlap, the primary analysis used 5 of the 6 studies and found an odds ratio of 2.3 (95% CI: 0.63-8.66; P=0.2) for major arrhythmic events (sustained VAs, sudden cardiac death, or appropriate ICD therapy) in asymptomatic patients with Brugada syndrome and inducible VA on electrophysiological study versus those without inducible VA. Ten studies were reviewed that evaluated ICD use in older patients and 4 studies that evaluated unique patient populations were identified. In our analysis, ICD implantation was associated with improved survival (overall hazard ratio: 0.75; 95% confidence interval: 0.67-0.83; P<0.001). Ten studies were identified that evaluated ICD use in patients with various comorbidities including renal disease, chronic obstructive pulmonary disease, atrial fibrillation, heart disease, and others. A random effects model demonstrated that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.72; 95% confidence interval: 0.65-0.79; P<0.0001), and a second "minimal overlap" analysis also found that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.61-0.82; P<0.0001). In 5 studies that included data on renal dysfunction, ICD implantation was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.60-0.85; P<0.001).


Asunto(s)
Cardiología/normas , Muerte Súbita Cardíaca/prevención & control , Guías de Práctica Clínica como Asunto/normas , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Complejos Prematuros Ventriculares/terapia , American Heart Association , Consenso , Medicina Basada en la Evidencia/normas , Humanos , Factores de Riesgo , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidad , Resultado del Tratamiento , Estados Unidos , Fibrilación Ventricular/complicaciones , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/mortalidad , Complejos Prematuros Ventriculares/complicaciones , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/mortalidad
7.
Circulation ; 137(1): 24-33, 2018 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-29046320

RESUMEN

BACKGROUND: Recognition of rates and causes of hard, patient-centered outcomes of death and cerebrovascular events (CVEs) after heart rhythm disorder management (HRDM) procedures is an essential step for the development of quality improvement programs in electrophysiology laboratories. Our primary aim was to assess and characterize death and CVEs (stroke or transient ischemic attack) after HRDM procedures over a 17-year period. METHODS: We performed a retrospective cohort study of all patients undergoing HRDM procedures between January 2000 and November 2016 at the Mayo Clinic. Patients from all 3 tertiary academic centers (Rochester, Phoenix, and Jacksonville) were included in the study. All in-hospital deaths and CVEs after HRDM procedures were identified and were further characterized as directly or indirectly related to the HRDM procedure. Subgroup analysis of death and CVE rates was performed for ablation, device implantation, electrophysiology study, lead extraction, and defibrillation threshold testing procedures. RESULTS: A total of 48 913 patients (age, 65.7±6.6 years; 64% male) who underwent a total of 62 065 HRDM procedures were included in the study. The overall mortality and CVE rates in the cohort were 0.36% (95% confidence interval [CI], 0.31-0.42) and 0.12% (95% CI, 0.09-0.16), respectively. Patients undergoing lead extraction had the highest overall mortality rate at 1.9% (95% CI, 1.34-2.61) and CVE rate at 0.62% (95% CI, 0.32-1.07). Among patients undergoing HRDM procedures, 48% of deaths directly related to the HDRM procedure were among patients undergoing device implantation procedures. Overall, cardiac tamponade was the most frequent direct cause of death (40%), and infection was the most common indirect cause of death (29%). The overall 30-day mortality rate was 0.76%, with the highest being in lead extraction procedures (3.08%), followed by device implantation procedures (0.94%). CONCLUSIONS: Half of the deaths directly related to an HRDM procedure were among the patients undergoing device implantation procedures, with cardiac tamponade being the most common cause of death. This highlights the importance of the development of protocols for the quick identification and management of cardiac tamponade even in procedures typically believed to be lower risk such as device implantation.


Asunto(s)
Arritmias Cardíacas/terapia , Procedimientos Quirúrgicos Cardíacos/mortalidad , Mortalidad Hospitalaria , Ataque Isquémico Transitorio/mortalidad , Accidente Cerebrovascular/epidemiología , Técnicas de Ablación/mortalidad , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/tendencias , Taponamiento Cardíaco/mortalidad , Causas de Muerte , Desfibriladores Implantables , Remoción de Dispositivos/mortalidad , Técnicas Electrofisiológicas Cardíacas/mortalidad , Femenino , Mortalidad Hospitalaria/tendencias , Humanos , Ataque Isquémico Transitorio/diagnóstico , Masculino , Persona de Mediana Edad , Marcapaso Artificial , Implantación de Prótesis/mortalidad , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/mortalidad , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA