Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Osteoarthritis Cartilage ; 29(5): 619-632, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33577959

RESUMEN

OBJECTIVE: To examine and compare the accuracy of conventional radiography (CR) and musculoskeletal ultrasonography (US) in the diagnosis of calcium pyrophosphate (CPP) crystals deposition disease (CPPD). DESIGN: A systematic search of electronic databases (PubMed, Embase, and Cochrane), conference abstracts and reference lists was undertaken. Studies which evaluated the accuracy of CR and/or US in the diagnosis of CPPD, using synovial fluid analysis (SFA), histology or classification criteria as reference tests were included. Subgroup analyses by anatomic site and by reference test were performed. RESULTS: Twenty-six studies were included. Using SFA/histology as reference test, CR and US showed an excellent (CR AUC = 0.889, 95%CI = 0.811-0.967) and an outstanding (US AUC = 0.954, 95%CI = 0.907-1.0) diagnostic accuracy (p < 0.01), respectively. Furthermore, US showed a higher sensitivity (0.85, 95%CI = 0.79-0.90 vs 0.47, 95%CI = 0.40-0.55) and only a little lower specificity (0.87, 95%CI = 0.83-0.91 vs 0.95, 95%CI = 0.92-0.97) than CR. A considerable heterogeneity between the studies was found, with adopted reference test being the main source of heterogeneity. In fact, subgroup analysis showed a significant change in the diagnostic accuracy of CR, but not of US, using Ryan and McCarty criteria or SFA/histology as reference test (CR: AUC = 0.956, 95%CI = 0.925-1.0 vs AUC = 0.889, 95%CI = 0.828-0.950, respectively, p < 0.01) (US: AUC = 0.922, 95%CI = 0.842-1.0 vs AUC = 0.957, 95%CI = 0.865-1.0, respectively, p = 0.08) CONCLUSIONS: Although US is more sensitive and a little less specific than CR for identifying CPP crystals, both these two techniques showed a great diagnostic accuracy and should be regarded as complementary to each other in the diagnostic work-up of patients with CPPD.


Asunto(s)
Condrocalcinosis/diagnóstico , Articulaciones/diagnóstico por imagen , Músculo Esquelético/diagnóstico por imagen , Pirofosfato de Calcio/análisis , Fascia/diagnóstico por imagen , Humanos , Ligamentos Articulares/diagnóstico por imagen , Radiografía , Sensibilidad y Especificidad , Líquido Sinovial/química , Tendones/diagnóstico por imagen , Ultrasonografía
2.
Plant Biol (Stuttg) ; 22 Suppl 1: 133-142, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30597710

RESUMEN

Among wild species used in potato breeding, Solanum commersonii displays the highest tolerance to low temperatures under both acclimated (ACC) and non-acclimated (NACC) conditions. It is also the first wild potato relative with a known whole genome sequence. Recent studies have shown that abiotic stresses induce changes in the expression of many small non-coding RNA (sncRNA). We determined the small non-coding RNA (sncRNAome) of two clones of S. commersonii contrasting in their cold response phenotypes via smRNAseq. Differential analysis provided evidence that expression of several miRNAs changed in response to cold stress conditions. Conserved miR408a and miR408b changed their expression under NACC conditions, whereas miR156 and miR169 were differentially expressed only under ACC conditions. We also report changes in tasiRNA and secondary siRNA expression under both stress conditions. Our results reveal possible roles of sncRNA in the regulatory networks associated with tolerance to low temperatures and provide useful information for a more strategic use of genomic resources in potato breeding.


Asunto(s)
Respuesta al Choque por Frío , MicroARNs , Solanum tuberosum , Solanum , Frío , Regulación de la Expresión Génica de las Plantas , MicroARNs/genética , ARN/genética , Bibliotecas de Moléculas Pequeñas , Solanum/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA