Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
ACS Nano ; 18(4): 3636-3650, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38227493

RESUMEN

Microwave thermotherapy (MWT) has shown great potential in cancer treatment due to its deep tissue penetration and minimally invasive nature. However, the poor microwave absorption (MA) properties of the microwave thermal sensitizer in the medical frequency band significantly limit the thermal effect of MWT and then weaken the therapeutic efficacy. In this paper, a Ni-based multilayer heterointerface nanomissile of MOFs-Ni-Ru@COFs (MNRC) with improved MA performance in the desired frequency band via introducing magnetic loss and dielectric loss is developed for MWT-based treatment. The loading of the Ni nanoparticle in MNRC mediates the magnetic loss, introducing the MA in the medical frequency band. The heterointerface formed in the MNRC by nanoengineering induces significant interfacial polarization, increasing the dielectric loss and then enhancing the generated MA performance. Moreover, MNRC with the strong MA performance in the desired frequency range not only enhances the MW thermal effect of MWT but also facilitates the electron and energy transfer, generating reactive oxygen species (ROS) at tumor sites to mediate microwave dynamic therapy (MDT). The strategy of strengthening the MA performance of the sensitizer in the medical frequency band to improve MWT-MDT provides a direction for expanding the clinical application of MWT in tumor treatment.


Asunto(s)
Síndrome de Cockayne , Neoplasias , Humanos , Microondas , Transferencia de Energía
2.
J Ultrasound Med ; 42(9): 1965-1975, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36880695

RESUMEN

OBJECTIVE: The purpose of this study is to accurately monitor temperature during microwave hyperthermia. We propose a temperature estimation model BP-Nakagami based on neural network for Nakagami distribution. METHODS: In this work, we designed the microwave hyperthermia experiment of fresh ex vivo pork tissue and phantom, collected ultrasonic backscatter data at different temperatures, modeled these data using Nakagami distribution, and calculated Nakagami distribution parameter m. A neural network model was built to train the relationship between Nakagami distribution parameter m and temperature, and a BP-Nakagami temperature model with good fitting was obtained. The temperature model is used to draw the two-dimensional temperature distribution map of biological tissues in microwave hyperthermia. Finally, the temperature estimated by the model is compared with the temperature measured by thermocouples. RESULTS: The error between the temperature estimated by the temperature model and the temperature measured by the thermocouple is within 1°C in the range of 25°C-50°C for ex vivo pork tissue, and the error between the temperature estimated by the temperature model and the temperature measured by the thermocouple is within 0.5°C in the range of 25°C-50°C for phantom. CONCLUSIONS: The results show that the temperature estimation model proposed by us is an effective model for monitoring the internal temperature change of biological tissues.


Asunto(s)
Hipertermia Inducida , Microondas , Humanos , Temperatura , Ultrasonido , Fantasmas de Imagen , Ultrasonografía/métodos
3.
Artículo en Inglés | MEDLINE | ID: mdl-33859707

RESUMEN

The effect of perioperative acupuncture on accelerating gastrointestinal function recovery has been reported in colorectal surgery and distal gastrectomy (Billroth-II). However, the evidence in pancreatectomy and other gastrectomy is still limited. A prospective, randomized controlled trial was conducted between May 2018 and August 2019. Consecutive patients undergoing pancreatectomy or gastrectomy in our hospital were randomly assigned to the electroacupuncture (EA) group and the control group. The patients in the EA group received transcutaneous EA on Bai-hui (GV20), Nei-guan (PC6), Tian-shu (ST25), and Zu-san-li (ST36) once a day in the afternoon, and the control group received sham EA. Primary outcomes were the time to first flatus and time to first defecation. In total, 461 patients were randomly assigned to the groups, and 385 were analyzed finally (EA group, n = 201; control group, n = 184). Time to first flatus (3.0 ± 0.7 vs 4.2 ± 1.0, P < 0.001) and first defecation (4.2 ± 0.9 vs 5.4 ± 1.2, P < 0.001) in the EA group were significantly shorter than those in the control group. Of patients undergoing pancreatectomy, those undergoing pancreaticoduodenectomy and intraoperative radiation therapy (IORT) surgery benefitted from EA in time to first flatus (P < 0.001) and first defecation (P < 0.001), while those undergoing distal pancreatectomy did not (P flatus=0.157, P defecation=0.007) completely. Of patients undergoing gastrectomy, those undergoing total gastrectomy and distal gastrectomy (Billroth-II) benefitted from EA (P < 0.001), as did those undergoing proximal gastrectomy (P=0.015). Patients undergoing distal gastrectomy (Billroth-I) benefitted from EA in time to first defecation (P=0.012) but not flatus (P=0.051). The time of parenteral nutrition, hospital stay, and time to first independent walk in the EA group were shorter than those in the control group. No severe EA complications were reported. EA was safe and effective in accelerating postoperative gastrointestinal function recovery. Patients undergoing pancreaticoduodenectomy, IORT surgery, total gastrectomy, proximal gastrectomy, or distal gastrectomy (Billroth-II) could benefit from EA. This trial is registered with NCT03291574.

4.
Technol Health Care ; 24 Suppl 2: S675-82, 2016 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-27177098

RESUMEN

In this paper, an Archimedean planar spiral antenna for the application of thermotherapy was designed. This type of antenna was chosen for its compact structure, flexible application and wide heating area. The temperature field generated by the use of this Two-armed Spiral Antenna in a muscle-equivalent phantom was simulated and subsequently validated by experimentation. First, the specific absorption rate (SAR) of the field was calculated using the Finite Element Method (FEM) by Ansoft's High Frequency Structure Simulation (HFSS). Then, the temperature elevation in the phantom was simulated by an explicit finite difference approximation of the bioheat equation (BHE). The temperature distribution was then validated by a phantom heating experiment. The results showed that this antenna had a good heating ability and a wide heating area. A comparison between the calculation and the measurement showed a fair agreement in the temperature elevation. The validated model could be applied for the analysis of electromagnetic-temperature distribution in phantoms during the process of antenna design or thermotherapy experimentation.


Asunto(s)
Simulación por Computador , Hipertermia Inducida/instrumentación , Hipertermia Inducida/métodos , Microondas , Temperatura , Algoritmos , Humanos , Modelos Biológicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA