Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Bioelectromagnetics ; 42(1): 86-94, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33305868

RESUMEN

Artificial materials that can simultaneously mimic the relative permittivity and conductivity of various human tissues are usually used in medical applications. However, the method of precisely designing these materials with designated values of both relative permittivity and conductivity at 3 T MRI resonance frequency is lacking. In this study, a reliable method is established to determine the compositions of artificial dielectric materials with designated relative permittivity and conductivity at 128 MHz. Sixty dielectric materials were produced using oil, sodium chloride, gelatin, and deionized water as the main raw materials. The dielectric properties of these dielectric materials were measured using the open-ended coaxial line method at 128 MHz. Nonlinear least-squares Marquardt-Levenberg algorithm was used to obtain the formula, establishing the relationship between the compositions of the dielectric materials and their dielectric properties at 128 MHz. The dielectric properties of the blood, gall bladder, muscle, skin, lung, and bone at 128 MHz were selected to verify the reliability of the obtained formula. For the obtained formula, the coefficient of determination and the expanded uncertainties with a coverage factor of k = 2 were 0.991% and 4.9% for relative permittivity and 0.992% and 6.4% for conductivity. For the obtained artificial materials measured using the open-ended coaxial line method, the maximal difference of relative permittivity and conductivity were 1.0 and 0.02 S/m, respectively, with respect to the designated values. In conclusion, the compositions of tissue-mimicking material can be quickly determined after the establishment of the formulas with the expanded uncertainties of less than 10%. Bioelectromagnetics. 2021;42:86-94. © 2020 Bioelectromagnetics Society.


Asunto(s)
Algoritmos , Pulmón , Conductividad Eléctrica , Humanos , Reproducibilidad de los Resultados , Agua
2.
Bioelectromagnetics ; 38(7): 522-532, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28715607

RESUMEN

The study was designed to identify differences in the dielectric properties of ex vivo colorectal cancerous tissues at different tumor stages. To date, 130 freshly excised colorectal cancerous specimens underwent measurement of both relative permittivity and conductivity on the serosal and mucosal surfaces of the carcinoma nidus, and the mucosa of the surgical resection margin ranging from 50 to 500 MHz at the Larmor frequencies. Tumor node metastasis staging was determined according to pathological reports for each patient. There were statistically significant differences in the relative permittivity of both colorectal cancerous serosa and mucosa among stages ≤I, II, III, and IV and between stages ≤II and ≥III (P < 0.05) at most frequencies under 300 MHz; statistically significant differences in conductivity were also observed for most of the measured frequencies (P < 0.05). The significant differences in dielectric characteristics among tumor stages, especially between early and advanced stages, have value for selecting appropriate surgical strategies. The presented ex vivo data provide important information for magnetic resonance electrical properties tomography in vivo system because the frequencies of 64 MHz (1.5T) and 128 MHz (3T) are usually used in clinical settings. Bioelectromagnetics. 38:522-532, 2017. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Neoplasias Colorrectales/patología , Adulto , Anciano , Anciano de 80 o más Años , Impedancia Eléctrica , Femenino , Humanos , Mucosa Intestinal/citología , Mucosa Intestinal/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Temperatura
3.
AIDS Care ; 24(6): 756-62, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22149005

RESUMEN

The purpose of this study was to analyze the cost and cost-effectiveness of methadone maintenance treatment (MMT) program in Dehong prefecture, Yunnan province, China. The cost-effectiveness analysis used process data retrospectively collected from the MMT clinics in Dehong Prefecture, Yunnan Province, from July 2005 to December 2007, a 30-month period available at the time of the study. Alternative estimates of the number of HIV infections prevented were calculated using incidence rate from cohort studies and retrospective studies. Program costs were collected retrospectively following standard methods using an ingredients methodology. The cost for each participant treated in MMT clinics was about $9.1-16.7 per month and the intervention averted 8.4-87.2 HIV infections with a cost-effectiveness of US$ 2509.3-4609.3 per HIV infection averted. This research demonstrates that MMT is a cost-effective intervention for reducing HIV transmission among injecting drug users, but the coverage of MMT intervention should be matched with the designed volume of MMT clinics to make the best use of resources.


Asunto(s)
Seropositividad para VIH/complicaciones , Metadona/economía , Narcóticos/economía , Narcóticos/uso terapéutico , Tratamiento de Sustitución de Opiáceos/economía , Abuso de Sustancias por Vía Intravenosa/economía , China/epidemiología , Estudios de Cohortes , Análisis Costo-Beneficio , Femenino , Humanos , Masculino , Metadona/uso terapéutico , Años de Vida Ajustados por Calidad de Vida , Estudios Retrospectivos , Abuso de Sustancias por Vía Intravenosa/tratamiento farmacológico , Abuso de Sustancias por Vía Intravenosa/epidemiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA