1.
Undersea Hyperb Med ; 49(3): 275-287, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36001560

RESUMEN

Introduction: The International Multicenter Registry for Hyperbaric Oxygen Therapy (International Report Registered Identifier DERR1-10.2196/18857) was established in 2011 to capture outcomes and complications data for both Undersea and Hyperbaric Medical Society (UHMS) approved and selected unapproved hyperbaric oxygen (HBO2) therapy indications. Methods: A Research Electronic Data Capture (REDCap) template was designed and distributed to all participating centers for prospective data collection. Centers contributed de-identified demographic, treatment, complications, and outcome data. This report provides summary data on sites and enrollment, as well as pre- and post-treatment data on quality of life (EQ-5D-5L questionnaire), head and neck radiationoutcomes, non-healing wounds (Strauss score), and idiopathic sudden sensorineural hearing loss. Data were analyzed mainly using the Wilcoxon signed-rank test. Results: Twenty-two centers contributed data for 2,880 patients. The most common UHMS-approved indication was delayed radiation injury, followed by enhancement of wound healing, and carbon monoxide poisoning. One hundred and twenty-five patients were treated for non-UHMS approved indications. Quality of life, head and neck radiation symptoms, Strauss wound scores, and hearing were significantly improved after HBO2. Complication rates were low and comparable to previous reports. The registry also offered the ability to analyze factors that affect outcomes, such as smoking and severity of hearing loss. Discussion: The registry accrues prospective data on defined outcomes from multiple centers and allows for analysis of factors affecting outcomes. This registry does not have a control group, which is a limitation. Nevertheless, the registry provides a unique, comprehensive dataset on HBO2 outcomes from multiple centers internationally.


Asunto(s)
Intoxicación por Monóxido de Carbono , Pérdida Auditiva Súbita , Oxigenoterapia Hiperbárica , Intoxicación por Monóxido de Carbono/terapia , Pérdida Auditiva Súbita/terapia , Humanos , Oxigenoterapia Hiperbárica/métodos , Oxígeno/efectos adversos , Calidad de Vida , Sistema de Registros
2.
Int J Audiol ; 60(7): 555-560, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33043734

RESUMEN

OBJECTIVE: Distortion product otoacoustic emission (DPOAE) mapping characterises cochlear function, can include both the 2f1-2f2 and 2f2-2f1 DPOAEs, and shows promise for tracking cochlear changes. DPOAE amplitude measurements are not as repeatable longitudinally as pure-tone audiometry, likely due in part to probe placement sensitivity. We hypothesised that DPOAE level map variation over multiple testing sessions could be minimised by replacing traditional rubber tips with custom-moulded probe tips. DESIGN: Traditional rubber tips (TRT) and custom-moulded probes tips (CMPT) were used to measure DPOAE level maps repeatedly over five sessions. Probe placement was assessed using a frequency sweep in the ear canal. Repeatability of the DPOAE level maps was assessed using a Bland-Altman analysis. Overall map repeatability was assessed by measuring differences in distortion product amplitude over sessions. STUDY SAMPLE: Crossover study with a convenience sample size of six adults. RESULTS: The CMPT frequency sweeps showed reduced variability in probe placement. The repeatability coefficient for individual DPOAEs measurements improved from 6.9 dB SPL with the TRT to 5.1 dB SPL with the CMPT. Map repeatability improved for most subjects with the CMPT.


Asunto(s)
Cóclea , Emisiones Otoacústicas Espontáneas , Estimulación Acústica , Adulto , Audiometría de Tonos Puros , Estudios Cruzados , Cultura , Humanos
3.
JMIR Res Protoc ; 9(8): e18857, 2020 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-32579537

RESUMEN

BACKGROUND: Hyperbaric oxygen (HBO2)-oxygen at pressures higher than atmospheric-is approved for 14 indications by the Undersea and Hyperbaric Medical Society. HBO2's main effect is to increase oxygen content in plasma and body tissues, which can counteract hypoxia or ischemia. Laboratory studies show that HBO2 has effects beyond relieving hypoxia (eg, promoting angiogenesis in irradiated tissue, anti-inflammatory effects, radiosensitization of tumors, hypoxia preconditioning, and fungal growth inhibition) and has potential to treat conditions such as inflammatory bowel disease and pyoderma gangrenosum. Lack of consistently collected outcome data on a large cohort of individuals receiving HBO2 therapy limits its use for both established and new indications. A course of therapy often involves 30-40 visits to a hyperbaric chamber, so the number of patients seen at any given center is constrained by chamber capacity. As a result, published HBO2 outcome data tend to be from small case series because few patients with a particular condition are treated at a given center. To solve this problem, a registry that collects and pools data systematically from multiple institutions has been established. OBJECTIVE: The aim of this study is to collect consistent outcome data across multiple hyperbaric centers to assess treatment effectiveness and establish a research consortium. METHODS: A consortium of hyperbaric centers who have agreed to collect consistent outcome data on all patients seen has been assembled. Data are collected at each participating center using Research Electronic Data Capture (REDCap), a web-based, data collection system used frequently for research. Standard outcome measures have been defined for each condition, which are programmed into the REDCap data collection templates. Governance is through a consortium agreement that defines data security, data sharing, publications, liability, and other issues. Centers obtain Institutional Review Board (IRB) and ethics approval to participate, either from their own institutions or by relying on the IRB at the coordinating center at Dartmouth College. Dissemination will occur through a yearly report and by publications based on the data in the registry. RESULTS: Early results from some common indications show significant pretreatment to posttreatment changes. Additional indications and outcome measures are being added using the procedures outlined in the consortium agreement. CONCLUSIONS: The registry collects consistent outcome information for a therapy that needs further study and a stronger evidence base. It also overcomes the challenge of collecting data from an adequate number of patients for both established and emerging indications by combining data collection from multiple centers. The data entry requirements should be within the capabilities of existing staff at any given hyperbaric center. By using REDCap, the registry can be expanded to include detailed information on particular indications and long-term follow-up on selected patients without significantly increasing the basic data entry requirements. Through the registry, a network of enrolled hyperbaric centers has been established that provides the basis for a clinical trial network. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/18857.

4.
Aerosp Med Hum Perform ; 88(6): 520-526, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-28539139

RESUMEN

INTRODUCTION: Virtual reality (VR) can provide exposure to nature for those living in isolated confined environments. We evaluated VR-presented natural settings for reducing stress and improving mood. METHODS: There were 18 participants (9 men, 9 women), ages 32 ± 12 yr, who viewed three 15-min 360° scenes (an indoor control, rural Ireland, and remote beaches). Subjects were mentally stressed with arithmetic before scenes. Electrodermal activity (EDA) and heart rate variability measured psycho-physiological arousal. The Positive and Negative Affect Schedule and the 15-question Modified Reality Judgment and Presence Questionnaire (MRJPQ) measured mood and scene quality. RESULTS: Reductions in EDA from baseline were greater at the end of the natural scenes compared to the control scene (-0.59, -0.52, and 0.32 µS, respectively). The natural scenes reduced negative affect from baseline ( 1.2 and 1.1 points), but the control scene did not ( 0.4 points). MRJPQ scores for the control scene were lower than both natural scenes (4.9, 6.7, and 6.5 points, respectively). Within the two natural scenes, the preferred scene reduced negative affect ( 2.4 points) more than the second choice scene ( 1.8 points) and scored higher on the MRJPQ (6.8 vs. 6.4 points). DISCUSSION: Natural scene VR provided relaxation both objectively and subjectively, and scene preference had a significant effect on mood and perception of scene quality. VR may enable relaxation for people living in isolated confined environments, particularly when matched to personal preferences.Anderson AP, Mayer MD, Fellows AM, Cowan DR, Hegel MT, Buckey JC. Relaxation with immersive natural scenes presented using virtual reality. Aerosp Med Hum Perform. 2017; 88(6):520526.


Asunto(s)
Terapia por Relajación/métodos , Estrés Psicológico/terapia , Terapia de Exposición Mediante Realidad Virtual/métodos , Adulto , Afecto , Atención , Femenino , Respuesta Galvánica de la Piel , Frecuencia Cardíaca , Humanos , Masculino , Estrés Psicológico/fisiopatología , Estrés Psicológico/psicología , Encuestas y Cuestionarios , Resultado del Tratamiento , Interfaz Usuario-Computador , Adulto Joven
5.
Int J Audiol ; 52(11): 783-8, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23992487

RESUMEN

OBJECTIVE: Our objective was to obtain reliable threshold measurements without a sound booth by using a passive noise-attenuating hearing protector combined with in-ear 1/3-octave band noise measurements to verify the ear canal was suitably quiet. DESIGN: We deployed laptop-based hearing testing systems to Tanzania as part of a study of HIV infection and hearing. An in-ear probe containing a microphone was used under the hearing protector for both the in-ear noise measurements and threshold audiometry. The 1/3-octave band noise spectrum from the microphone was displayed on the operator's screen with acceptable levels in grey and unacceptable levels in red. Operators attempted to make all bars grey, but focused on achieving grey bars at 2000 Hz and above. STUDY SAMPLE: 624 adults and 197 children provided 3381 in-ear octave band measurements. Repeated measurements from 144 individuals who returned for testing on three separate occasions were also analysed. RESULTS: In-ear noise levels exceeded the maximum permissible ambient noise levels (MPANL) for ears not covered, but not the dB SPL levels corresponding to 0 dB HL between 2000-4000 Hz. In-ear noise measurements were repeatable over time. CONCLUSIONS: Reliable audiometry can be performed using a passive noise-attenuating hearing protector and in-ear noise measurements.


Asunto(s)
Audiometría de Tonos Puros/instrumentación , Umbral Auditivo , Dispositivos de Protección de los Oídos , Oído , Ruido/prevención & control , Estimulación Acústica , Adulto , Niño , Diseño de Equipo , Humanos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Espectrografía del Sonido , Tanzanía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA