Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Am Coll Cardiol ; 56(14): 1089-98, 2010 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-20863952

RESUMEN

OBJECTIVES: We report the first clinical studies of intracardiac ST-segment monitoring in ambulatory humans to alert them to significant ST-segment shifts associated with thrombotic occlusion. BACKGROUND: Despite improvements in door-to-balloon times, delays in symptom-to-door times of 2 to 3 h remain. Early alerting of the presence of acute myocardial infarction could prompt patients to seek immediate medical evaluation. METHODS: Intracardiac monitoring was performed in 37 patients at high risk for acute coronary syndromes. The implanted monitor continuously evaluated the patients' ST segments sensed from a conventional pacemaker right ventricle apical lead, and alerted patients to detected ischemic events. RESULTS: During follow-up (median 1.52 years, range 126 to 974 days), 4 patients had ST-segment changes of ≥3 SDs of their normal daily range, in the absence of an elevated heart rate. This in combination with immediate hospital monitoring led to angiogram and/or intravascular ultrasonography, which confirmed thrombotic coronary occlusion/ruptured plaque. The median alarm-to-door time was 19.5 min (6, 18, 21, and 60 min, respectively). Alerting for demand-related ischemia at elevated heart rates, reflective of flow-limiting coronary obstructions, occurred in 4 patients. There were 2 false-positive ischemia alarms related to arrhythmias, and 1 alarm due to a programming error that did not prompt cardiac catheterization. CONCLUSIONS: Shifts exceeding 3 SD from a patient's daily intracardiac ST-segment range may be a sensitive/specific marker for thrombotic coronary occlusion. Patient alerting was associated with a median alert-to-door time of 19.5 min for patients at high risk of recurrent coronary syndromes who typically present with 2- to 3-h delays.


Asunto(s)
Síndrome Coronario Agudo/prevención & control , Enfermedad de la Arteria Coronaria/diagnóstico , Electrocardiografía Ambulatoria/métodos , Técnicas Electrofisiológicas Cardíacas/instrumentación , Isquemia Miocárdica/diagnóstico , Anciano , Enfermedad de la Arteria Coronaria/prevención & control , Técnicas Electrofisiológicas Cardíacas/métodos , Diseño de Equipo , Seguridad de Equipos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Isquemia Miocárdica/prevención & control , Recurrencia , Medición de Riesgo , Rotura Espontánea
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA