Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Anesthesiology ; 124(6): 1384-93, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27054366

RESUMEN

BACKGROUND: Due to an increase in implantable device-related anesthesia pain medicine claims, the authors investigated anesthesia liability associated with these devices. METHODS: After institutional review board approval, the authors identified 148 pain medicine device claims from 1990 or later in the Anesthesia Closed Claims Project Database. Device-related damaging events included medication administration events, infections, hematomas, retained catheter fragments, cerebrospinal fluid leaks, cord or cauda equina trauma, device placed at wrong level, stimulator incorrectly programmed, delay in recognition of granuloma formation, and other issues. RESULTS: The most common devices were implantable drug delivery systems (IDDS; 64%) and spinal cord stimulators (29%). Device-related care consisted of surgical device procedures (n = 107) and IDDS maintenance (n = 41). Severity of injury was greater in IDDS maintenance claims (56% death or severe permanent injury) than in surgical device procedures (26%, P < 0.001). Death and brain damage in IDDS maintenance claims resulted from medication administration errors (n = 13; 32%); spinal cord injury resulted from delayed recognition of granuloma formation (n = 9; 22%). The most common damaging events for surgical device procedures were infections, inadequate pain relief, cord trauma, retained catheter fragments, and subcutaneous hygroma. Care was more commonly assessed as less than appropriate (78%) and payments more common (63%) in IDDS maintenance than in surgical device procedure claims (P < 0.001). CONCLUSIONS: Half of IDDS maintenance claims were associated with death or permanent severe injury, most commonly from medication errors or failure to recognize progressive neurologic deterioration. Practitioners implanting or managing devices for chronic pain should exercise caution in these areas to minimize patient harm.


Asunto(s)
Dolor Crónico/terapia , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/instrumentación , Bombas de Infusión Implantables/efectos adversos , Seguro de Responsabilidad Civil/estadística & datos numéricos , Mala Praxis/estadística & datos numéricos , Terapia por Estimulación Eléctrica/economía , Femenino , Humanos , Bombas de Infusión Implantables/economía , Bombas de Infusión Implantables/estadística & datos numéricos , Revisión de Utilización de Seguros/economía , Revisión de Utilización de Seguros/estadística & datos numéricos , Seguro de Responsabilidad Civil/economía , Masculino , Mala Praxis/economía , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA