Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Circ Arrhythm Electrophysiol ; 11(8): e005631, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-30354308

RESUMEN

Background Both endocardial trigger elimination and epicardial substrate modification are effective in treating ventricular fibrillation (VF) in Brugada syndrome. However, the primary approach and the characteristics of patients who respond to endocardial ablation remain unknown. Methods Among 123 symptomatic Brugada syndrome patients (VF, 63%; syncope, 37%), ablation was performed in 21 VF/electrical storm patients, the majority of whom were resistant to antiarrhythmic drugs. Results Careful endocardial mapping revealed that 81% of the patients had no specific findings, whereas 19% of the patients, who experienced the most frequent VF episodes with notching of the QRS in lead V1, had delayed low-voltage fractionated endocardial electrograms. Ablation of VF triggers followed by endocardial substrate modification was performed in the right ventricular outflow tract in 85% of the cases and in the right ventricle in 15%. VF triggers could not be completely eliminated in 1 patient and VF became noninducible in 14 (88%) patients among 16 patients who underwent VF induction with normalization of Brugada-type ECG in 3. During follow-up (56.14±36.95 months), VF recurrence was observed in 7 patients. Importantly, all patients who had nothing of QRS in lead V1 did not respond to endocardial ablation despite presence of VF-triggering ectopic beats during ablation. Conclusions With careful documentation of VF-triggering ectopic beats and detailed endocardial mapping, endocardial VF trigger elimination followed by endocardial substrate modification has an excellent long-term outcome, whereas presence of QRS notching in lead V1 was associated with high VF recurrence suggesting epicardial substrate ablation as effective initial approach.


Asunto(s)
Síndrome de Brugada/complicaciones , Ablación por Catéter/métodos , Endocardio/cirugía , Frecuencia Cardíaca , Fibrilación Ventricular/cirugía , Potenciales de Acción , Adulto , Antiarrítmicos/uso terapéutico , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatología , Ablación por Catéter/efectos adversos , Resistencia a Medicamentos , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Endocardio/fisiopatología , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/etiología , Fibrilación Ventricular/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA