Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 25(8): 824-833, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24724831

RESUMEN

INTRODUCTION: It is unclear whether extended pulmonary vein antrum isolation (PVAI) plus nonpulmonary vein (non-PV) trigger elimination prevents more arrhythmia recurrence than PVAI alone in patients with mechanical mitral valve (MMV) undergoing AF ablation. This study compared the efficacy and long-term outcome of 2 ablation strategies--PVAI alone versus extended PVAI plus non-PV trigger elimination--for the treatment of AF in patients with MMV. METHODS AND RESULTS: One hundred and nine consecutive AF patients with MMV were divided into 2 groups: standard PVAI was performed in group 1 (N = 45); in group 2 (N = 64) PVAI was extended to the LA posterior wall, LA septum, and CS; and all non-PV triggers were eliminated. Patients were followed up for 3 years. At the 12th month, 7 (15.6%) patients in group 1, and 39 (60.9%) patients in group 2 were arrhythmia free (log-rank P < 0.001). Four patients (8.9%; 3 cases of AT and 1 case of AF) from group 1, and 12 patients (18.8%; 9 cases of AT, and 3 cases of AFL) from group 2 experienced very late recurrence. At 36 ± 7 months follow-up, the cumulative recurrence after a single procedure was 42/45 (93.3%) in group 1, and 37/64 (57.8%) in group 2 (log-rank P < 0.001). CONCLUSION: Compared with the standard PVAI alone, a strategy including extended PVAI and non-PV trigger elimination is associated with a higher 12-month and long-term arrhythmia-free survival in patients with MMV undergoing AF ablation. Very late recurrence may occur years after the initial procedure with focal AT as the most common type of recurrent arrhythmia.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Válvula Mitral/cirugía , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , China , Supervivencia sin Enfermedad , Técnicas Electrofisiológicas Cardíacas , Europa (Continente) , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Diseño de Prótesis , Venas Pulmonares/fisiopatología , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
2.
J Interv Card Electrophysiol ; 40(1): 23-31, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24633546

RESUMEN

PURPOSE: Contact with cardiac tissue is a determinant of lesion efficacy during atrial fibrillation (AF) ablation. The Sensei®X Robotic Catheter System (Hansen Medical, CA) has been validated for contact force sensing. The electrical coupling index (ECI) from the EnSite Contact™ system (St. Jude Medical, MN) has been validated as an indicator of tissue contact. We aimed at analyzing ECI behavior during radiofrequency (RF) pulses maintaining a stable contact through the robotic navigation contact system. METHODS: In 15 patients (age, 59 ± 12) undergoing AF ablation, pulmonary vein (PV) isolation was guided by the Sensei®X System, employing the Contact™ catheter. RESULTS: During the procedure, we assessed ECI changes associated with adequate contact based on the IntelliSense® force-sensing technology (Hansen Medical, CA. Baseline contact (27 ± 8 g/cm(2)) ECI value was 99 ± 13, whereas ECI values in a noncontact site (0 g/cm(2)) and in a light contact site (1-10 g/cm(2)) were respectively 66 ± 12 and 77 ± 10 (p < 0.0001). Baseline contact ECI values were not different depending on AF presentation (paroxysmal AF, 98 ± 9; persistent AF, 100 ± 9) or on cardiac rhythm (sinus rhythm, 97 ± 7; AF,101 ± 10). In all PVs, ECI was significantly reduced during and after ablation (ECI during RF, 56 ± 15; ECI after RF, 72 ± 16; p < 0.001). A mean reduction of 32.2% during RF delivery and 25.4% immediately after RF discontinuation compared with baseline ECI was observed. CONCLUSIONS: Successful PV isolation is associated with a significant decrease in ECI of at least 20 %. This may be used as a surrogate marker of effective lesion in AF ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Cirugía Asistida por Computador , Anciano , Ablación por Catéter/instrumentación , Impedancia Eléctrica , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pletismografía de Impedancia/métodos , Presión , Robótica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA