RESUMEN
OBJECTIVE: To determine how a large scale, multicomponent, pharmacy based intervention to reduce proton pump inhibitor (PPI) overuse affected prescribing patterns, healthcare utilization, and clinical outcomes. DESIGN: Difference-in-difference study. SETTING: US Veterans Affairs Healthcare System, in which one regional network implemented the overuse intervention and all 17 others served as controls. PARTICIPANTS: All individuals receiving primary care from 2009 to 2019. INTERVENTION: Limits on PPI refills for patients without a documented indication for long term use, voiding of PPI prescriptions not recently filled, facilitated electronic prescribing of H2 receptor antagonists, and education for patients and clinicians. MAIN OUTCOME MEASURES: The primary outcome was the percentage of patients who filled a PPI prescription per 6 months. Secondary outcomes included percentage of days PPI gastroprotection was prescribed in patients at high risk for upper gastrointestinal bleeding, percentage of patients who filled either a PPI or H2 receptor antagonist prescription, hospital admission for acid peptic disease in older adults appropriate for PPI gastroprotection, primary care visits for an upper gastrointestinal diagnosis, upper endoscopies, and PPI associated clinical conditions. RESULTS: The number of patients analyzed per interval ranged from 192 607 to 250 349 in intervention sites and from 3 775 953 to 4 360 868 in control sites, with 26% of patients receiving PPIs before the intervention. The intervention was associated with an absolute reduction of 7.3% (95% confidence interval -7.6% to -7.0%) in patients who filled PPI prescriptions, an absolute reduction of 11.3% (-12.0% to -10.5%) in PPI use among patients appropriate for gastroprotection, and an absolute reduction of 5.72% (-6.08% to -5.36%) in patients who filled a PPI or H2 receptor antagonist prescription. No increases were seen in primary care visits for upper gastrointestinal diagnoses, upper endoscopies, or hospital admissions for acid peptic disease in older patients appropriate for gastroprotection. No clinically significant changes were seen in any PPI associated clinical conditions. CONCLUSIONS: The multicomponent intervention was associated with reduced PPI use overall but also in patients appropriate for gastroprotection, with minimal evidence of either clinical benefits or harms.
Asunto(s)
Prestación Integrada de Atención de Salud , Enfermedades Gastrointestinales , Humanos , Anciano , Inhibidores de la Bomba de Protones/uso terapéutico , Antagonistas de los Receptores H2 de la Histamina/uso terapéutico , Hemorragia Gastrointestinal/inducido químicamenteRESUMEN
BACKGROUND: Decreasing low-value colonoscopy is critical to optimizing access for high-need patients, particularly in resource-constrained environments such as those created by the COVID-19 pandemic. We hypothesized that rates of screening colonoscopy overuse would decline during COVID compared to pre-COVID due to enhanced procedural scrutiny and prioritization in the setting of constrained access. OBJECTIVE: To characterize impacts of COVID-19 on screening colonoscopy overuse DESIGN: Retrospective national cohort study using Veterans Health Administration administrative data PARTICIPANTS: Veterans undergoing screening colonoscopy in Q4 2019 (pre-COVID) and Q4 2020 (COVID) at 109 endoscopy facilities MAIN MEASURES: Rates of screening colonoscopy overuse KEY RESULTS: 18,376 screening colonoscopies were performed pre-COVID, 19% (3,641) of which met overuse criteria. While only 9,360 screening colonoscopies were performed in Q4 2020, 25% met overuse criteria. Overall change in median facility-level overuse during COVID compared to pre-COVID was 6% (95%CI 5%-7%), with significant variability across facilities (IQR: 2%-11%). Of colonoscopies meeting overuse criteria, the top reason for overuse in both periods was screening colonoscopy performed <9 years after previous screening procedure (55% pre-COVID, 49% during COVID). The largest shifts in overuse category were in screening procedures performed <9 years after prior screening colonoscopy (-6% decline COVID vs. pre-COVID) and screening procedures performed in patients below average-risk screening age (i.e., age <40 (5% increase COVID compared to pre-COVID), age 40-44 (4% increase COVID vs. pre-COVID)). Within facility performance was stable over time; 83/109 facilities changed their performance by <=1 quartile during COVID compared to pre-COVID. CONCLUSIONS: Despite pandemic-related resource constraints and enhanced procedural scrutiny and prioritization in the setting of COVID-related backlogs, screening colonoscopy overuse rates remained roughly stable during COVID compared to pre-COVID, with continued variability across facilities. These data highlight the need for systematic and concerted efforts to address overuse, even in the face of strong external motivating factors.
Asunto(s)
COVID-19 , Neoplasias Colorrectales , Prestación Integrada de Atención de Salud , Estados Unidos/epidemiología , Humanos , Adulto , Estudios de Cohortes , Estudios Retrospectivos , Neoplasias Colorrectales/diagnóstico , Pandemias , United States Department of Veterans Affairs , COVID-19/epidemiología , Colonoscopía , Tamizaje Masivo , Detección Precoz del Cáncer/métodosRESUMEN
BACKGROUND: Low-value use of screening colonoscopy is wasteful and potentially harmful to patients. Decreasing low-value colonoscopy prevents procedural complications, saves patient time and reduces patient discomfort, and can improve access by reducing procedural demand. The objective of this study was to develop and validate an electronic measure of screening colonoscopy overuse using International Classification of Diseases, Tenth Edition codes and then apply this measure to estimate facility-level overuse to target quality improvement initiatives to reduce overuse in a large integrated healthcare system. METHODS: Retrospective national observational study of US Veterans undergoing screening colonoscopy at 119 Veterans Health Administration (VHA) endoscopy facilities in 2017. A measure of screening colonoscopy overuse was specified by an expert workgroup, and electronic approximation of the measure numerator and denominator was performed ('electronic measure'). The electronic measure was then validated via manual record review (n=511). Reliability statistics (n=100) were calculated along with diagnostic test characteristics of the electronic measure. The measure was then applied to estimate overall rates of overuse and facility-level variation in overuse among all eligible patients. RESULTS: The electronic measure had high specificity (99%) and moderate sensitivity (46%). Adjusted positive predictive value and negative predictive value were 33% and 95%, respectively. Inter-rater reliability testing revealed near perfect agreement between raters (k=0.81). 269 572 colonoscopies were performed in VHA in 2017 (88 143 classified as screening procedures). Applying the measure to these 88 143 screening colonoscopies, 24.5% were identified as potential overuse. Median facility-level overuse was 22.5%, with substantial variability across facilities (IQR 19.1%-27.0%). CONCLUSIONS: An International Classification of Diseases, Tenth Edition based electronic measure of screening colonoscopy overuse has high specificity and improved sensitivity compared with a previous International Classification of Diseases, Ninth Edition based measure. Despite increased focus on reducing low-value care and improving access, a quarter of VHA screening colonoscopies in 2017 were identified as potential low-value procedures, with substantial facility-level variability.
Asunto(s)
Prestación Integrada de Atención de Salud , Clasificación Internacional de Enfermedades , Estados Unidos , Humanos , Estudios Retrospectivos , United States Department of Veterans Affairs , Reproducibilidad de los Resultados , Colonoscopía/métodosRESUMEN
Sodium nitrite (NaNO2) is an industrial chemical that is frequently used as a food additive to prevent botulism and enhance glossiness, such as curing meat. In addition, in some regions, water source NaNO2 concentrations exceed standard regulatory levels. Whether the excessive intake of NaNO2 has toxic effects on female fertility and fetal development remain unknown. In this study, we administered ICR mice control saline, low-dose NaNO2 (60â¯mg/kg/day), or high-dose NaNO2 (120â¯mg/kg/day) by intragastric gavage for 21 days. We then assessed oocyte morphology, spindle-chromosome dynamics, mitochondrial distribution, ATP content, apoptotic cell numbers, DNA damage levels, histone modifications, reactive oxygen species (ROS) levels, and offspring survival. Results showed that NaNO2 treatment decreased oocyte number, impaired polar body extrusion, and increased zona pellucida thickness in oocytes. Furthermore, NaNO2 disrupted MII spindle integrity, caused abnormal mitochondrial distribution, decreased ATP content, and increased levels of ROS and H3K4me2. Moreover, the number of oocytes in early stages of apoptosis and with levels of DNA damage increased in NaNO2-treated mice along with decreased offspring numbers and survival rates. We demonstrated the negative effects of NaNO2 on female reproductive abilities in mice.