Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Sensors (Basel) ; 20(15)2020 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-32726931

RESUMEN

Ventricular fibrillation (VF) signals are characterized by highly volatile and erratic electrical impulses, the analysis of which is difficult given the complex behavior of the heart rhythms in the left (LV) and right ventricles (RV), as sometimes shown in intracardiac recorded Electrograms (EGM). However, there are few studies that analyze VF in humans according to the simultaneous behavior of heart signals in the two ventricles. The objective of this work was to perform a spectral and a non-linear analysis of the recordings of 22 patients with Congestive Heart Failure (CHF) and clinical indication for a cardiac resynchronization device, simultaneously obtained in LV and RV during induced VF in patients with a Biventricular Implantable Cardioverter Defibrillator (BICD) Contak Renewal IVTM (Boston Sci.). The Fourier Transform was used to identify the spectral content of the first six seconds of signals recorded in the RV and LV simultaneously. In addition, measurements that were based on Information Theory were scrutinized, including Entropy and Mutual Information. The results showed that in most patients the spectral envelopes of the EGM sources of RV and LV were complex, different, and with several frequency peaks. In addition, the Dominant Frequency (DF) in the LV was higher than in the RV, while the Organization Index (OI) had the opposite trend. The entropy measurements were more regular in the RV than in the LV, thus supporting the spectral findings. We can conclude that basic stochastic processing techniques should be scrutinized with caution and from basic to elaborated techniques, but they can provide us with useful information on the biosignals from both ventricles during VF.


Asunto(s)
Fibrilación Ventricular , Arritmias Cardíacas , Desfibriladores Implantables , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Insuficiencia Cardíaca , Ventrículos Cardíacos , Humanos , Fibrilación Ventricular/diagnóstico
2.
Sensors (Basel) ; 20(11)2020 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-32485879

RESUMEN

During the last years, attention and controversy have been present for the first commercially available equipment being used in Electrocardiographic Imaging (ECGI), a new cardiac diagnostic tool which opens up a new field of diagnostic possibilities. Previous knowledge and criteria of cardiologists using intracardiac Electrograms (EGM) should be revisited from the newly available spatial-temporal potentials, and digital signal processing should be readapted to this new data structure. Aiming to contribute to the usefulness of ECGI recordings in the current knowledge and methods of cardiac electrophysiology, we previously presented two results: First, spatial consistency can be observed even for very basic cardiac signal processing stages (such as baseline wander and low-pass filtering); second, useful bipolar EGMs can be obtained by a digital processing operator searching for the maximum amplitude and including a time delay. In addition, this work aims to demonstrate the functionality of ECGI for cardiac electrophysiology from a twofold view, namely, through the analysis of the EGM waveforms, and by studying the ventricular repolarization properties. The former is scrutinized in terms of the clustering properties of the unipolar an bipolar EGM waveforms, in control and myocardial infarction subjects, and the latter is analyzed using the properties of T-wave alternans (TWA) in control and in Long-QT syndrome (LQTS) example subjects. Clustered regions of the EGMs were spatially consistent and congruent with the presence of infarcted tissue in unipolar EGMs, and bipolar EGMs with adequate signal processing operators hold this consistency and yielded a larger, yet moderate, number of spatial-temporal regions. TWA was not present in control compared with an LQTS subject in terms of the estimated alternans amplitude from the unipolar EGMs, however, higher spatial-temporal variation was present in LQTS torso and epicardium measurements, which was consistent through three different methods of alternans estimation. We conclude that spatial-temporal analysis of EGMs in ECGI will pave the way towards enhanced usefulness in the clinical practice, so that atomic signal processing approach should be conveniently revisited to be able to deal with the great amount of information that ECGI conveys for the clinician.


Asunto(s)
Arritmias Cardíacas , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Arritmias Cardíacas/diagnóstico , Mapeo del Potencial de Superficie Corporal , Análisis por Conglomerados , Humanos
3.
Sensors (Basel) ; 18(5)2018 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-29724033

RESUMEN

The intracardiac electrical activation maps are commonly used as a guide in the ablation of cardiac arrhythmias. The use of catheters with force sensors has been proposed in order to know if the electrode is in contact with the tissue during the registration of intracardiac electrograms (EGM). Although threshold criteria on force signals are often used to determine the catheter contact, this may be a limited criterion due to the complexity of the heart dynamics and cardiac vorticity. The present paper is devoted to determining the criteria and force signal profiles that guarantee the contact of the electrode with the tissue. In this study, we analyzed 1391 force signals and their associated EGM recorded during 2 and 8 s, respectively, in 17 patients (82 ± 60 points per patient). We aimed to establish a contact pattern by first visually examining and classifying the signals, according to their likely-contact joint profile and following the suggestions from experts in the doubtful cases. First, we used Principal Component Analysis to scrutinize the force signal dynamics by analyzing the main eigen-directions, first globally and then grouped according to the certainty of their tissue-catheter contact. Second, we used two different linear classifiers (Fisher discriminant and support vector machines) to identify the most relevant components of the previous signal models. We obtained three main types of eigenvectors, namely, pulsatile relevant, non-pulsatile relevant, and irrelevant components. The classifiers reached a moderate to sufficient discrimination capacity (areas under the curve between 0.84 and 0.95 depending on the contact certainty and on the classifier), which allowed us to analyze the relevant properties in the force signals. We conclude that the catheter-tissue contact profiles in force recordings are complex and do not depend only on the signal intensity being above a threshold at a single time instant, but also on time pulsatility and trends. These findings pave the way towards a subsystem which can be included in current intracardiac navigation systems assisted by force contact sensors, and it can provide the clinician with an estimate of the reliability on the tissue-catheter contact in the point-by-point EGM acquisition procedure.


Asunto(s)
Arritmias Cardíacas/terapia , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/normas , Humanos , Reproducibilidad de los Resultados
4.
Cardiol J ; 22(3): 241-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25428732

RESUMEN

BACKGROUND: The implantable loop recorder (ILR) is a useful tool for diagnosis of syncope or palpitations. Its easy use and safety have extended its use to secondary hospitals (those without an Electrophysiology Lab). The aim of the study was to compare results between secondary and tertiary hospitals. METHODS: National prospective and multicenter registry of patients with an ILR inserted for clinical reasons. Data were collected in an online database. The follow-up ended when the first diagnostic clinical event occurred, or 1 year after implantation. Data were analyzed according to the center of reference; hospitals with Electrophysiology Lab were considered Tertiary Hospitals, while those hospitals without a lab were considered Secondary Hospitals. RESULTS: Seven hundred and forty-three patients (413 [55.6%] men; 65 ± 16 year-old): 655 (88.2%) from Tertiary Centers (TC) and 88 (11.8%) from Secondary Centers (SC). No differences in clinical characteristics between both groups were found. The electrophysiologic study and the tilt table test were conducted more frequently in Tertiary Centers. Follow-up was conducted for 680 (91.5%) patients: 91% in TC and 94% in SC. There was a higher rate of final diagnosis among SC patients (55.4% vs. 30.8%; p < 0.001). Tertiary Hospital patients showed a trend towards a higher rate of neurally mediated events (20% vs. 4%), while bradyarrhythmias were more frequent in SC (74% vs. 60%; p = 0.055). The rate of deaths and adverse events was similar in both populations. CONCLUSIONS: Patients with an ILR in SC and TC have differences in terms of the use of complementary tests, but not in clinical characteristics. There was a higher rate of diagnosis in Secondary Hospital patients.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Electrodos Implantados , Centros de Atención Secundaria , Síncope/diagnóstico , Telemetría/instrumentación , Anciano , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Sistema de Registros , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , España , Síncope/mortalidad , Síncope/fisiopatología , Centros de Atención Terciaria , Pruebas de Mesa Inclinada
5.
J Cardiovasc Electrophysiol ; 24(3): 364-6, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23140400

RESUMEN

A 39-year-old woman with no structural heart disease and frequent episodes of sudden onset palpitations was referred for the electrophysiological study. During the study, a slightly irregular narrow QRS tachycardia with AV dissociation was repeatedly induced and spontaneously terminated. Apparently, irregular cycles and termination of the tachycardia were related to the dissociated sinus rhythm: atrial depolarizations timed when the AV junction was refractory were able to reset the tachycardia, while early atrial depolarizations caused its termination. This observation was enough to diagnose the tachycardia mechanism in our case.


Asunto(s)
Sistema de Conducción Cardíaco/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia Ectópica de Unión/diagnóstico , Adulto , Diagnóstico Diferencial , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Valor Predictivo de las Pruebas , Periodo Refractario Electrofisiológico , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Taquicardia Ectópica de Unión/fisiopatología , Factores de Tiempo
6.
Rev. esp. cardiol. (Ed. impr.) ; 60(6): 660-663, jun. 2007. ilus, tab
Artículo en Es | IBECS | ID: ibc-058050

RESUMEN

Se asume que la superioridad de la inyección femoral de suero salino agitado para la detección del foramen oval permeable comparada con la antecubital se debe principalmente al efecto de las corrientes intrauriculares de la desembocadura de las cavas. Nos propusimos evaluar la influencia del lugar de inyección de contraste en el grado de opacificación auricular derecha en ecografía intracardiaca. Se puntuó de 0 a 4 el grado de opacificación obtenido tras inyecciones venosas por vía antecubital y femoral de contraste salino en 21 pacientes. Se comprobó que el grado de opacificación auricular derecha es mayor tras la inyección femoral que la antecubital (3,76 frente a 1,62; p < 0,001). Los futuros estudios que comparen ambas vías de inyección de salino deberían controlar el grado de opacificación auricular derecha (AU)


It is thought that femoral injection of agitated saline contrast is better for detecting patent foramen ovale than antecubital injection mainly because of the nature of intraatrial flow where the venae cavae enter the heart. Our aim was to investigate the effect of the contrast injection site on the degree of right atrial opacification seen on intracardiac echocardiography. The degree of right atrial opacification after each femoral or antecubital injection of saline contrast was scored from 0­4 in 21 patients. It was shown that the degree of right atrial opacification was greater after femoral than antecubital injection (3.76 vs. 1.62; P<.001). Future studies comparing the two routes of saline contrast injection should control for the degree of right atrial opacification (AU)


Asunto(s)
Masculino , Femenino , Adulto , Persona de Mediana Edad , Humanos , Atrios Cardíacos , Ecocardiografía/métodos , Enfermedades Cardiovasculares , Medios de Contraste/administración & dosificación , Técnicas Electrofisiológicas Cardíacas/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA