1.
Acta Pharmacol Sin ; 29(12): 1499-506, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19026170

RESUMEN

AIM: To develop and validate a novel precolumn derivatization method for the quantitative determination and pharmacokinetic application of acetylshikonin in macaque monkeys by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). METHODS: 2-Mercaptoethanol was added to the blood sample as the derivatization reagent. The derivatization reaction formed 1 major derivation product, which was well correlated with acetylshikonin. The acetylshikonin concentrations in the biological samples were calculated by quantitative determination of the major derivation product using LC-ESI- MS/MS. Separation was achieved using a C18 column (2 mm x 50 mm, 5 microm) at room temperature and a linear gradient elution with a mobile phase containing methanol (1.96% acetic acid) and 10% methanol in water (1.96% acetic acid and 10 mmol/L ammonium acetate) at a flow rate of 0.2 mL/min. In addition, the major derivative, named derivative III, was identified by UV spectra, MS, and the (1)H-NMR and (13)C-NMR spectra. RESULTS: Good linearity was obtained within the range of 5 and 2000 ng/mL (r>0.99 using a linear regression model with 1/x2 weighting) for acetylshikonin. The interday and intraday precisions were found to be less than 12.3%, with the exception of the lowest concentration, which was less than 17.2%. The interday and intraday accuracies, which were between -3% and 0.6%, were also observed. After the administration of acetylshikonin (80 mg/kg, po) in macaque monkeys, the pharmacokinetic parameters were obtained through the non-compartmental analysis, where the area under the concentration-time curve to the last measurable concentration, the terminal elimination halflife, and the mean residual time were 615.4+/-206.5 ng x dh/mL,12.3+/-1.6 h, and 10.2+/-0.7 h, respectively. CONCLUSION: The method was validated and applied to the quantitative determination and pharmacokinetic study of acetylshikonin in the blood samples of macaque monkeys.


Asunto(s)
Antraquinonas , Cromatografía Liquida/métodos , Medicamentos Herbarios Chinos , Mercaptoetanol/química , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masas en Tándem/métodos , Animales , Antraquinonas/sangre , Antraquinonas/química , Antraquinonas/farmacocinética , Carbazoles/química , Medicamentos Herbarios Chinos/química , Medicamentos Herbarios Chinos/metabolismo , Macaca , Estructura Molecular , Resonancia Magnética Nuclear Biomolecular , Propionatos/química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA