Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 20(suppl_2): ii22-ii27, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29722857

RESUMEN

Aims: Currently, comparative data on procedural and long-term clinical outcome of outflow tract (OT) idiopathic ventricular arrhythmia (IVA) ablation with manual (MAN), contact force (CF), and magnetic navigation system (MNS) ablation are lacking. The aim of this study was to compare the procedural and long-term clinical outcome of MAN, CF, and MNS ablation of OT IVAs. Methods and results: Seventy-three patients (31 MAN, 17 CF, and 25 MNS patients; consecutive per group) with OT IVA, who underwent catheter ablation in our centre were analysed. Procedural success rates (success at the end of the procedure), procedural data and long-term follow-up data were compared. Baseline patient demographics were comparable. Procedural success rates were similar (MAN 81%, 71% CF, and MNS 92%; P = 0.20). Median fluoroscopy time was shorter in the MNS group: MAN 29 (16-38), CF 37 (21-46), and MNS 13 (10-20) min (P = 0.002 for MNS vs. CF and MAN). The overall complication rate was: MAN 10%, CF 0%, and MNS 0% (P = 0.12). Median follow-up was: MAN 2184 (1672-2802), CF 1721 (1404-1913), and MNS 3031 (2524-3286) days (P <0.001). Recurrences occurred in MAN 46%, CF 50%, and MNS 46% (P = 0.97). Repeat procedures were performed in MAN 20%, CF 40%, and MNS 33% (P = 0.32). Conclusion: Procedural and long-term clinical outcome of OT IVA ablation are equal for MAN, CF, and MNS. MNS has a favourable procedural safety profile due to the shorter fluoroscopy time compared with MAN and CF.


Asunto(s)
Cateterismo Cardíaco/métodos , Ablación por Catéter/métodos , Magnetismo/métodos , Cirugía Asistida por Computador/métodos , Taquicardia Ventricular/cirugía , Potenciales de Acción , Adulto , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Humanos , Magnetismo/instrumentación , Imanes , Masculino , Persona de Mediana Edad , Presión , Recurrencia , Sistema de Registros , Factores de Riesgo , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/instrumentación , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Transductores de Presión , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 28(1): 78-84, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27625076

RESUMEN

BACKGROUND: Multiple mechanisms have been proposed for idiopathic premature ventricular contractions (PVCs) originating from the outflow tracts (OTs). Recent observations such as the coexistence of these arrhythmias with atrioventricular nodal reentrant tachycardias and the association between discrete prepotentials and successful ablation sites of ventricular arrhythmias (VAs) from the OTs suggest a common link. OBJECTIVE: In this case series we draw attention to a unique association between accessory pathways (APs) and idiopathic PVCs from the OTs, disappearing after AP ablation. METHODS: We identified 6 cases in collaboration with several international electrophysiology centers, which presented with pre-excitation in association with OT, and in 1 case inflow tract (IT), PVCs on 12-lead surface ECG. RESULTS: Six cases displayed pre-excitation and PVCs, in 5 cases originating from the right ventricular outflow tract (RVOT) and in 1 case from the right ventricular inflow tract (RVIT). In all patients, PVCs were monomorphic and had fixed coupling intervals, in 3 cases presenting in bigeminy. Catheter ablation of the AP led to the simultaneous disappearance of PVCs in 5 of 6 cases. The sites of ablation were remote from the OTs in all these cases. In most cases, the occurrence of OT PVCs was closely associated with the presence of pre-excitation. CONCLUSION: The coexistence of pre-excitation and PVCs from the OTs and the fact that in 5 of 6 cases PVCs disappeared after AP ablation suggests a common mechanism for arrhythmia genesis.


Asunto(s)
Fascículo Atrioventricular Accesorio/cirugía , Ablación por Catéter , Sistema de Conducción Cardíaco/cirugía , Complejos Prematuros Ventriculares/cirugía , Fascículo Atrioventricular Accesorio/diagnóstico , Fascículo Atrioventricular Accesorio/fisiopatología , Potenciales de Acción , Adolescente , Adulto , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Inducción de Remisión , Factores de Tiempo , Resultado del Tratamiento , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA