Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
World J Biol Psychiatry ; 13(7): 501-9, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21599563

RESUMEN

OBJECTIVES: To address the role of latent T. gondii infection in schizophrenia we studied the influence of latent toxoplasmosis on brain morphology. METHODS: An optimized voxel-based morphometry of magnetic resonance imaging was analyzed by analysis of variance with diagnosis and seropositivity as factors in 44 schizophrenic patients (12 T. gondii positive) and 56 controls (13 T. gondii positive). RESULTS: Grey matter (GM) volume was reduced in schizophrenia patients compared with controls in the cortical regions, hippocampus and in the caudate. In the schizophrenia sample we found a significant reduction of GM volume in T. gondii positive comparing with T. gondii-negative patients bilaterally in the caudate, median cingulate, thalamus and occipital cortex and in the left cerebellar hemispheres. T. gondii-positive and -negative controls did not differ in any cluster. Among participants seropositive to T. gondii the reduction of GM in the schizophrenia subjects was located in the same regions when comparing the entire sample (11,660 over-threshold voxels (P ≤ 0.05, FWR corrected). The differences between T. gondii-negative patients and controls consisted only of 289 voxels in temporal regions. CONCLUSIONS: Our study is the first to document that latent toxoplasmosis reduces GM in schizophrenia but not in controls.


Asunto(s)
Encéfalo/microbiología , Encéfalo/patología , Esquizofrenia/microbiología , Esquizofrenia/patología , Toxoplasmosis Cerebral/microbiología , Toxoplasmosis Cerebral/patología , Adulto , Análisis de Varianza , Mapeo Encefálico/métodos , Corteza Cerebral/microbiología , Corteza Cerebral/patología , Ensayo de Inmunoadsorción Enzimática , Femenino , Hipocampo/microbiología , Hipocampo/patología , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Masculino , Esquizofrenia/complicaciones , Lóbulo Temporal/microbiología , Lóbulo Temporal/patología , Tálamo/microbiología , Tálamo/patología , Toxoplasmosis Cerebral/complicaciones
2.
J Pharm Biomed Anal ; 54(5): 979-86, 2011 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-21168298

RESUMEN

Microplate scintillation counters are utilized routinely in drug metabolism laboratories for the off-line radioanalysis of fractions collected during HPLC radioprofiling. In this process, the current fraction collection technology is limited by the number of plates that can be used per injection as well as the potential for sample loss due to dripping or spraying as the fraction collector head moves from well to well or between plates. More importantly, sample throughput is limited in the conventional process, since the collection plates must be manually exchanged after each injection. The Collect PAL, an innovative multiple-plate fraction collector, was developed to address these deficiencies and improve overall sample throughput. It employs a zero-loss design and has sub-ambient temperature control. Operation of the system is completely controlled with software and up to 24 (96- or 384-well) fraction collection plates can be loaded in a completely automated run. The system may also be configured for collection into various-sized tubes or vials. At flow rates of 0.5 or 1.0 mL/min and at collection times of 10 or 15s, the system precisely delivered 83-µL fractions (within 4.1% CV) and 250-µL fractions (within 1.4% CV), respectively, of three different mobile phases into 12 mm × 32 mm vials. Similarly, at a flow rate of 1 mL/min and 10s collection times, the system precisely dispensed mobile phase containing a [(14)C]-radiolabeled compound across an entire 96-well plate (% CV was within 5.3%). Triplicate analyses of metabolism test samples containing [(14)C]buspirone and its metabolites, derived from three different matrices (plasma, urine and bile), indicated that the Collect PAL produced radioprofiles that were reproducible and comparable to the current technology; the % CV for 9 selected peaks in the radioprofiles generated with the Collect PAL were within 9.3%. Radioprofiles generated by collecting into 96- and 384-well plates were qualitatively comparable; however, the peak resolution was greater in the profiles that were collected in 384-well plates due to the collection of a larger number of fractions per minute. In conclusion, this new and innovative fraction collector generated radioprofile results that were comparable to current technology and should provide a major improvement in capacity and throughput for radioprofiling studies.


Asunto(s)
Evaluación Preclínica de Medicamentos/métodos , Ensayos Analíticos de Alto Rendimiento/métodos , Preparaciones Farmacéuticas/metabolismo , Radioisótopos/análisis , Conteo por Cintilación/métodos , Animales , Bilis/metabolismo , Buspirona/metabolismo , Buspirona/orina , Radioisótopos de Carbono/análisis , Cromatografía Líquida de Alta Presión/instrumentación , Cromatografía Líquida de Alta Presión/métodos , Perros , Evaluación Preclínica de Medicamentos/instrumentación , Ensayos Analíticos de Alto Rendimiento/instrumentación , Humanos , Preparaciones Farmacéuticas/orina , Reproducibilidad de los Resultados , Conteo por Cintilación/instrumentación , Manejo de Especímenes , Espectrometría de Masas en Tándem/instrumentación , Espectrometría de Masas en Tándem/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA