Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Spine J ; 29(6): 1297-1303, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32206868

RESUMEN

PURPOSE: Cement augmentation of pedicle screws is able to improve screw anchorage in osteoporotic vertebrae but is associated with a high complication rate. The goal of this study was to evaluate the impact of different cement volumes on pedicle screw fatigue strength. METHODS: Twenty-five human vertebral bodies (T12-L4) were collected from donors between 73 and 97 years of age. Bone density (BMD) was determined by quantitative computed tomography. Vertebral bodies were instrumented by conventional pedicle screws, and unilateral cement augmentation was performed. Thirteen vertebrae were augmented with a volume of 1 ml and twelve with a volume of 3 ml bone cement. A fatigue test was performed using a cranial-caudal sinusoidal, cyclic load (0.5 Hz) with increasing compression force (100 N + 0.1 N/cycles). RESULTS: The load to failure was 183.8 N for the non-augmented screws and was increased significantly to 268.1 N (p < 0.001) by cement augmentation. Augmentation with 1 ml bone cement increased the fatigue load by 41% while augmentation with 3 ml increased the failure load by 51% compared to the non-augmented screws, but there was no significant difference in fatigue loads between the specimens with screws augmented with 1 ml and screws augmented with 3 ml of bone cement (p = 0.504). CONCLUSION: Cement augmentation significantly increases pedicle screw stability. The benefit of augmentation on screw anchorage was not significantly affected by reducing the applied volume of cement from 3 ml to 1 ml. Considering the high risk of cement leakage during augmentation, we recommend the usage of a reduced volume of 1 ml bone cement for each pedicle screw. These slides can be retrieved under Electronic Supplementary Material .


Asunto(s)
Tornillos Pediculares , Fenómenos Biomecánicos , Cementos para Huesos , Densidad Ósea , Humanos , Vértebras Lumbares , Tomografía Computarizada por Rayos X
2.
Eur Spine J ; 27(8): 1964-1971, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29948322

RESUMEN

PURPOSE: Cement augmentation of pedicle screws is known to increase their mechanical strength. Aim was to evaluate the impact of cement augmentation on pedicle screw fatigue strength in dependence of the bone mineral density (BMD). METHODS: Twenty-one human L2 vertebral bodies from donors between 19 and 96 years of age were used for in vitro experiments. BMD was measured using quantitative computed tomography (QCT). Two pedicle screws were inserted in each specimen and unilaterally augmented with bone cement. Fatigue testing was performed using a cranio-caudal sinusoidal, cyclic load (0.5 Hz) with increasing compression force (100 N + 0.1 N/cycles). Results were evaluated for the BMD groups: normal: BMD > 120 mg/cm3, osteopenic: BMD 80-120 mg/cm3, and osteoporotic: BMD < 80 mg/cm3 bone mass. RESULTS: There was a significant correlation between fatigue force and BMD for the non-augmented and augmented screws (non-augmented R2 = 0.839, p < 0.001; augmented R2 = 0.551, p < 0.001). There was a significantly increased fatigue strength of the augmented screws over the non-augmented screws in the osteoporotic group (p = 0.001), while the differences in the other groups were not significant (normal p = 0.818/osteopenic p = 0.132). CONCLUSIONS: The benefit of pedicle screw cement augmentation significantly depends on the bone mineral density and has the greatest extent of increased fatigue strength in osteoporotic vertebrae. Preoperative measurement of the BMD is strongly recommended to predict the benefit of augmentation and reinforce the decision for cement augmentation. These slides can be retrieved under Electronic Supplementary Material.


Asunto(s)
Cementos para Huesos/uso terapéutico , Densidad Ósea/fisiología , Vértebras Lumbares/cirugía , Osteoporosis/fisiopatología , Tornillos Pediculares , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos/fisiología , Cadáver , Análisis de Falla de Equipo/métodos , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/fisiopatología , Masculino , Ensayo de Materiales/métodos , Persona de Mediana Edad , Osteoporosis/diagnóstico por imagen , Falla de Prótesis , Tomografía Computarizada por Rayos X , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA