Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Cardiothorac Vasc Anesth ; 38(1): 148-154, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37953172

RESUMEN

OBJECTIVES: The authors report their experience of a protocol for deep sedation with ketamine in spontaneous respiration during the pulsed-field ablation (PFA) of atrial fibrillation (AF). DESIGN: Observational, prospective, nonrandomized fashion. SETTING: Single-center hospitalized patients. PARTICIPANTS: All consecutive patients undergoing PFA of AF. INTERVENTIONS: Patients undergoing deep sedation with intravenous ketamine. MEASUREMENTS AND MAIN RESULTS: The authors' sedation protocol involves the intravenous administration of fentanyl (1.5 µg/kg) and midazolam (2 mg) at low doses before local anesthesia with lidocaine. A ketamine adjunct (1 mg/kg) in 5-minute boluses was injected about 5 minutes before the first PFA delivery. The authors enrolled 117 patients (age = 59 ± 10 y, 74.4% males, body mass index = 27.6 ± 5 kg/m2, fluoroscopy time = 24 ± 14 minutes, skin-to-skin time = 80 ± 40 minutes and PFA LA dwell time = 24 ± 7 minutes). By the end of the procedure, pulmonary vein isolation had been achieved in all patients using PFA alone. The mean time under sedation was 54.9 ± 6 minutes, with 92 patients (79%) being sedated for <1 hour. A satisfactory Ramsay Sedation Scale level before ketamine administration was achieved in all patients, except one (80.3% of the patients with rank 3; 18.4% with rank 2). In all procedures, the satisfaction level was found acceptable by both the patient and the primary operator (satisfactory in 98.2% of cases). All patients achieved a Numeric Rating Scale for Pain ≤3 (none or mild). No major procedure or anesthesia-related complications were reported. CONCLUSION: The authors' standardized sedation protocol with the administration of drugs with rapid onset and pharmacologic offset at low doses was safe and effective, with an optimal degree of patient and operator satisfaction.


Asunto(s)
Fibrilación Atrial , Sedación Profunda , Ketamina , Propofol , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Estudios Prospectivos , Administración Intravenosa , Anestesia Local , Fibrilación Atrial/cirugía , Respiración
2.
J Cardiovasc Med (Hagerstown) ; 21(9): 641-647, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32740497

RESUMEN

AIMS: The main cause of atrial fibrillation recurrence after catheter ablation is pulmonary vein reconnection. The purpose of this retrospective study was to analyse the electophysiological findings in patients undergoing repeat procedures after an index cryoballoon ablation (CB-A) and presenting with permanency of pulmonary vein isolation (PVI) in all veins. In addition, we sought to compare the latter with a similar group of patients with reconnected veins at the redo procedure. METHODS: A total of 132 patients (81 men, 60.7 ±â€Š12.4 years) who underwent CB-A for paroxysmal atrial fibrillation (PAF) were enrolled. Indication for the redo procedure was symptomatic PAF in 83 (63%), persistent atrial fibrillation (PerAF) in 32 (24%) or persistent regular atrial tachycardia (RAT) in 17 (13%) patients. RESULTS: Seventy-five (57%) patients presented a pulmonary vein reconnection (pulmonary vein group) during the redo procedure, whereas 57 (43%) had no pulmonary vein reconnection (non-pulmonary vein group). The non-pulmonary vein group exhibited significantly more non-pulmonary vein foci and atrial flutters than the pulmonary vein group after induction protocol (51 vs. 24%, P = 0.002 and 67 vs. 36%, P = 0.003, respectively). Twenty-two (29.3%) patients of the pulmonary vein group and 20 (35%) patients of the non-pulmonary vein group had atrial fibrillation/RAT recurrence after a mean follow-up of 12.5 ±â€Š8 months. The survival analysis demonstrated no statistical significance in recurrence between both groups (log rank P = 0.358). CONCLUSION: Atrial fibrillation/RAT recurrence in patients after CB-A with durable PVI is significantly associated with non-pulmonary vein foci and atrial flutters. No statistically different success rate regarding atrial fibrillation/RAT freedom was detected between the pulmonary vein and non-pulmonary vein groups after redoing RF-CA.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Aleteo Atrial/cirugía , Ablación por Catéter , Criocirugía , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Taquicardia Supraventricular/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Aleteo Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Estudios Retrospectivos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/fisiopatología , Resultado del Tratamiento
3.
Int J Cardiol ; 275: 104-106, 2019 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-30327133

RESUMEN

BACKGROUND: The occurrence of sustained ventricular arrhythmias (SVA) may be influenced by environmental factors. We aimed to investigate annual periodic trends of SVA from the intracardiac electrograms (IEGMs) stored in the implantable defibrillators (ICDs) or cardiac resynchronization therapy (CRT-D) recipients. METHODS: Data from the Home Monitoring Expert Alliance project, a pooled repository of remote monitoring transmissions were analyzed. All IEGMs stored were independently adjudicated by three cardiac electrophysiologists. Periodicity of SVA was evaluated with Generalized Estimating Equations (GEE) models, including periodic terms depending on months in a year. RESULTS: A total of 2936 ICD/CRT-D patients (median age 70 years, 79.6% male) were followed for a median period of 25[13-44] months. Most prevalent structural heart diseases were ischemic (50.8%) and idiopathic dilated (30.6%) cardiomyopathies. Overall, 942 (32.1%) patients experienced a total of 4824 SVA. At GEE analysis, we found a significant periodic component (p = 0.048) when considering both shocked and non-shocked episodes. SVA less frequently occurred in Junes and Julies (3.7 × 1000 patient-month). No evidence of significant periodicity was collected in the subgroup of ischemic patients. CONCLUSIONS: In this RM-based cohort of ICD/CRT-T patients, we observed an annual periodicity of SVA occurrence, with a lower incidence in summer months.


Asunto(s)
Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas/métodos , Sistema de Registros , Estaciones del Año , Taquicardia Ventricular/epidemiología , Telemetría/estadística & datos numéricos , Anciano , Femenino , Humanos , Incidencia , Italia/epidemiología , Masculino , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia
4.
Heart Rhythm ; 16(6): 879-887, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30594641

RESUMEN

BACKGROUND: Abnormal delayed electrograms (EGMs) from the anterior wall of the right ventricular outflow tract (RVOT) epicardium have become the ablation target in Brugada syndrome (BrS). OBJECTIVE: The aim of this study was to analyze the safety, feasibility, and efficacy of a novel hybrid thoracoscopic approach to perform epicardial RVOT radiofrequency ablation in BrS. METHODS: Thirty-six patients with BrS (26 men (72.2%); mean age 36.6±15.8 years; range 3-63 years) who underwent hybrid thoracoscopic epicardial ablation of RVOT from January 2016 to April 2018 were included in this study. Two expert electrophysiologists analyzed the EGMs during ajmaline challenge and guided the surgeon to perform ablation. Ajmaline challenge was repeated after 1 month to assess the absence of the BrS electrocardiographic pattern. Patients were followed by remote monitoring and outpatient visits every 6 months. RESULTS: The elimination of all abnormal EGMs was achieved in 94.4% of patients. After a mean follow-up of 16 ± 8 months (range 6-30 months), freedom from ventricular arrhythmias was obtained in 7 (77.8%) patients in secondary prevention 9/36 (25%) and in 24 (100%) patients in primary prevention 24/36 (75%). Major complications were observed in 1 patient (2.8%), who experienced late cardiac tamponade. CONCLUSION: Hybrid thoracoscopic epicardial RVOT ablation in BrS is a safe and feasible approach, allowing direct visualization of ablation during radiofrequency delivery. Because of ventricular arrhythmia recurrences, implantable cardioverter-defibrillator implantation is still mandatory in patients treated in secondary prevention and with high risk.


Asunto(s)
Síndrome de Brugada , Taponamiento Cardíaco , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas/métodos , Ventrículos Cardíacos , Complicaciones Posoperatorias/diagnóstico , Taquicardia Ventricular , Cirugía Torácica Asistida por Video/métodos , Adulto , Ajmalina/farmacología , Antiarrítmicos/farmacología , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatología , Síndrome de Brugada/cirugía , Taponamiento Cardíaco/diagnóstico , Taponamiento Cardíaco/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Estudios de Factibilidad , Femenino , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/cirugía , Humanos , Masculino , Pericardio/cirugía , Recurrencia , Ajuste de Riesgo , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA