Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Neurosci Methods ; 378: 109659, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35772608

RESUMEN

BACKGROUND: Neuromodulation is a rapidly expanding therapeutic option considered within neuropsychiatry, pain and rehabilitation therapy. Combining electrostimulation with feedback from fMRI can provide information about the mechanisms underlying the therapeutic effects, but so far, such studies have been hampered by the lack of technology to conduct safe and accurate experiments. Here we present a system for fMRI compatible electrical stimulation, and the first proof-of-concept neuroimaging data with deep brain stimulation (DBS) in pigs obtained with the device. NEW METHOD: The system consists of two modules, placed in the control and scanner room, connected by optical fiber. The system also connects to the MRI scanner to timely initiate the stimulation sequence at start of scan. We evaluated the system in four pigs with DBS in the subthalamic nucleus (STN) while we acquired BOLD responses in the STN and neocortex. RESULTS: We found that the system delivered robust electrical stimuli to the implanted electrode in sync with the preprogrammed fMRI sequence. All pigs displayed a DBS-STN induced neocortical BOLD response, but none in the STN. COMPARISONS WITH EXISTING METHOD: The system solves three major problems related to electric stimuli and fMRI examinations, namely preventing distortion of the fMRI signal, enabling communication that synchronize the experimental conditions, and surmounting the safety hazards caused by interference with the MRI scanner. CONCLUSIONS: The fMRI compatible electrical stimulator circumvents previous problems related to electroceuticals and fMRI. The system allows flexible modifications for fMRI designs and stimulation parameters, and can be customized to electroceutical applications beyond DBS.


Asunto(s)
Estimulación Encefálica Profunda , Núcleo Subtalámico , Animales , Estimulación Eléctrica , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Núcleo Subtalámico/diagnóstico por imagen , Núcleo Subtalámico/fisiología , Porcinos
2.
Scand J Clin Lab Invest ; 82(4): 261-266, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35758940

RESUMEN

We have established and describe two measurement procedures to diagnose possible zinc (Zn) deficiency; albumin-corrected Zn concentration and available free Zn-binding capacity. Reference intervals for both biomarkers were established in healthy adults from the Danish population. The clinical usefulness of the measurement procedures was investigated in patients with cirrhosis and in patients given parenteral nutrition due to short bowel syndrome. The results of both methods indicate that there is a risk of overdiagnosing Zn deficiency based on low plasma Zn concentrations. Needless Zn supplementation may thus be avoided by using the albumin-corrected Zn concentration or available free Zn-binding capacity.


Asunto(s)
Albúminas , Zinc , Adulto , Biomarcadores , Humanos
3.
Int J Circumpolar Health ; 80(1): 1972525, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34455939

RESUMEN

Selenium levels in the Inuit population of Greenland have been declining during the last decades. The association between Selenium and asthma has been investigated previously, but with conflicting results. The objective was to measure human serum Se (s-Se) in Greenlandic seafood processing workers, to compare with levels recorded in previous decades and to establish if s-Se is associated with asthma or lung function. Data, including questionnaire answers, spirometry, skin-prick test and s-Se from 324 seafood processing workers in Greenland were collected during 2016-2017. Mean s-Se values were compared by t-test and one-way ANOVA. Associations between s-Se and asthma, symptoms from the lower airways at work and lung function were assessed using linear regression. The mean s-Se was 96.2 µg/L. S-Se was higher among non-smokers and workers living in settlements. Workers with asthma did not have s-Se levels significantly different from those of non-asthmatics. We found a positive association between s-Se levels and FEV1 values. Selenium levels appear to continue declining in Greenland, presumably because of a more Westernised lifestyle. The health effects of declining Selenium levels remain unclear. We did not establish an association between s-Se and asthma, but we did record a positive association between s-Se and FEV1.


Asunto(s)
Asma , Selenio , Asma/diagnóstico , Asma/epidemiología , Groenlandia/epidemiología , Humanos , Alimentos Marinos/análisis , Selenio/análisis , Espirometría
4.
Eur J Pharm Biopharm ; 165: 193-202, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33979660

RESUMEN

Alpinia galanga oil (AGO) has an anesthetic activity but its water insoluble property limits its clinical applications. The aim of the present study was to develop a self-nanoemulsifying drug delivery system of AGO (SNEDDS-AGO) to avoid the use of organic solvent and investigate AGO transportation pathway and anesthetic activity. Three optimized formulations from a contour plots of droplet size; SNEDDS-AGO-1, SNEDDS-AGO-2, and SNEDDS-AGO-3, composed of AGO, Miglyol 812, Cremophor RH 40, Capmul MCM EP, and ethanol at the ratios of 40:10:35:10:5, 40:20:15:20:5, and 60:10:15:10:5, respectively were selected as they possessed different droplet size of 62 ± 0.5, 107 ± 2.8, and 207 ± 4.3 nm, respectively. It was found that the droplet size played an important role in fish anesthesia. SNEDDS-AGO-3 showed the longest anesthetic induction time (270 sec) (p < 0.03). Transportation pathway and skin permeation of SNEDDS-AGO-2 were investigated using nile red labelled AGO and detected by fluorescence microscope. AGO was found mostly in brain, gills, and skin suggesting that the transportation pathway of AGO in zebrafish is passing through the gills and skin to the brain. SNEDDS-AGO formulations showed significantly higher permeation through the skin than AGO ethanolic solution. In conclusion, SNEDDS is a promising delivery system of AGO.


Asunto(s)
Alpinia/química , Anestésicos Locales/administración & dosificación , Sistemas de Liberación de Medicamentos/métodos , Aceites de Plantas/administración & dosificación , Administración Cutánea , Anestésicos Locales/química , Anestésicos Locales/farmacocinética , Animales , Disponibilidad Biológica , Liberación de Fármacos , Emulsiones , Excipientes/química , Tamaño de la Partícula , Aceites de Plantas/química , Aceites de Plantas/farmacocinética , Rizoma/química , Piel/metabolismo , Solubilidad , Pez Cebra
5.
Ann Clin Biochem ; 57(3): 249-252, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32252535

RESUMEN

BACKGROUND: Plasma viscosity is an important biomarker both in diagnostics and treatment monitoring of plasma cell dyscrasias and other disorders with hyperviscosity syndrome as a clinical manifestation. Here, we investigate the performance of a new microfluidic-based viscometer for clinical use, establish a new reference range to be used with this instrument and determine the importance of sampling temperature. METHODS: The microVisc™ viscometer was evaluated for within-run and between-run imprecision and bias using standardized reference material (Paragon controls) and Seronorm™ control material. The reference range was established for the adult population using EDTA-plasma from 120 healthy blood donors. Sampling temperature was investigated by drawing and transporting blood at room temperature and 37°C and comparing the viscosity between the two sampling methods. RESULTS: The microfluidic-based viscometer performed well, and imprecision was comparable to ReoRox® G2 free oscillation rheometer. A new reference range for the adult Danish population was established as 1.2-1.5 mPa s at 37°C. Furthermore, sampling temperature at room temperature and 37°C was investigated, and there was no difference in results obtained. CONCLUSIONS: MicroVisc™ is suitable for measuring plasma viscosity in a clinical setting and results can be evaluated using the established reference range. Blood sampling for viscosity analysis can be performed as a standard procedure at room temperature.


Asunto(s)
Viscosidad Sanguínea , Microfluídica/instrumentación , Donantes de Sangre , Pruebas Diagnósticas de Rutina , Femenino , Humanos , Masculino , Valores de Referencia
6.
Chemosphere ; 204: 243-250, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29660537

RESUMEN

Saponin-rich plant extracts contain bioactive natural compounds and have many applications, e.g. as biopesticides and biosurfactants. The composition of saponin-rich plant extracts is very diverse, making environmental monitoring difficult. In this study various ecotoxicity data as well as exposure data have been collected to explore which compounds in the plant extract are relevant as plant protection agents and furthermore to clarify which compounds may cause undesired side-effects due to their toxicity. Hence, we quantified the toxicity of different fractions (saponins/non-saponins) in the plant extracts on the aquatic crustacean Daphnia magna and zebrafish (Danio rerio) embryos. In addition, we tested the toxicity changes during saponin degradation as well. The results confirm that saponins are responsible for the majority of toxicity (85.1-93.6%) of Quillaja saponaria extract. We, therefore, suggest saponins to be the main target of saponin-rich plant extracts, for instance in the saponin-based biopesticide regulation. Furthermore, we suggest that an abundant saponin fraction, QS-18 from Q. saponaria, can be a key monitoring target to represent the environmental concentration of the saponins, as it contributes with 26% and 61% of the joint toxicity to D. magna and D. rerio, respectively out of the total saponins. The degradation products of saponins are 3-7 times less toxic than the parent compound; therefore the focus should be mainly on the parent compounds.


Asunto(s)
Extractos Vegetales/química , Saponinas/toxicidad , Animales , Daphnia/efectos de los fármacos , Quillaja/química , Saponinas/química , Pez Cebra
7.
Scand J Infect Dis ; 35(11-12): 800-7, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14723353

RESUMEN

The aim of this study was to monitor the prevalence of drug resistance mutations in newly diagnosed HIV-1 positive individuals in Denmark. In addition we assessed the prevalence of non-B subtypes based on phylogenetic analysis of the pol gene. Plasma samples from 104 newly diagnosed HIV-1 positive patients were obtained in the year 2000. The entire protease gene and 320 amino acids of the reverse transcriptase gene were genotyped. Sequences were obtained from 97 patients. No subjects displayed primary resistance mutations in the protease gene, whereas all carried 1 or more secondary mutations. Resistance mutations in the RT-gene associated with NRTI-resistance were found in 1 patient, who was infected with zidovudine resistant HIV-1 harbouring the M41L mutation in combination with T215S and L210S. The T215S mutation has been showed to be associated with reversion of zidovudine resistance. The T215S mutation was found in 1 additional patient. The subtype distribution was subtype B 59%, C 18%, A 8%, CRF02_AG 5%, CRF01_AE 4%, D 3% and G 2%. We found 2 patients (2%) with mutations associated with resistance in the RT-gene and none in the protease gene indicating a low prevalence of resistant HIV-1 in Denmark in the year 2000.


Asunto(s)
Fármacos Anti-VIH/uso terapéutico , Farmacorresistencia Viral Múltiple , Infecciones por VIH/diagnóstico , Infecciones por VIH/tratamiento farmacológico , VIH-1/efectos de los fármacos , Mutación Puntual/genética , Adolescente , Adulto , Anciano , Fármacos Anti-VIH/farmacología , Western Blotting , Niño , Estudios de Cohortes , Análisis Mutacional de ADN , ADN Viral/análisis , ADN Viral/genética , Dinamarca/epidemiología , Femenino , Infecciones por VIH/epidemiología , Proteasa del VIH/genética , Transcriptasa Inversa del VIH/genética , VIH-1/genética , VIH-1/aislamiento & purificación , Humanos , Masculino , Pruebas de Sensibilidad Microbiana , Persona de Mediana Edad , Farmacogenética , Prevalencia , Muestreo , Pruebas Serológicas , Carga Viral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA