Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Genet Med ; 25(4): 100352, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36473599

RESUMEN

PURPOSE: TANGO2 deficiency disorder (TDD), an autosomal recessive disease first reported in 2016, is characterized by neurodevelopmental delay, seizures, intermittent ataxia, hypothyroidism, and life-threatening metabolic and cardiac crises. The purpose of this study was to define the natural history of TDD. METHODS: Data were collected from an ongoing natural history study of patients with TDD enrolled between February 2019 and May 2022. Data were obtained through phone or video based parent interviews and medical record review. RESULTS: Data were collected from 73 patients (59% male) from 57 unrelated families living in 16 different countries. The median age of participants at the time of data collection was 9.0 years (interquartile range = 5.3-15.9 years, range = fetal to 31.8 years). A total of 24 different TANGO2 alleles were observed. Patients showed normal development in early infancy, with progressive delay in developmental milestones thereafter. Symptoms included ataxia, dystonia, and speech difficulties, typically starting between the ages of 1 to 3 years. A total of 46/71 (65%) patients suffered metabolic crises, and of those, 30 (65%) developed cardiac crises. Metabolic crises were significantly decreased after the initiation of B-complex or multivitamin supplementation. CONCLUSION: We provide the most comprehensive review of natural history of TDD and important observational data suggesting that B-complex or multivitamins may prevent metabolic crises.


Asunto(s)
Ataxia , Convulsiones , Adolescente , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Embarazo , Atención Prenatal
2.
PLoS One ; 14(6): e0217282, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31242221

RESUMEN

BACKGROUND: In previous pilot work we demonstrated that a novel automated signal analysis tool could accurately identify successful ablation sites during Wolff-Parkinson-White (WPW) ablation at a single center. OBJECTIVE: We sought to validate and refine this signal analysis tool in a larger multi-center cohort of children with WPW. METHODS: A retrospective review was performed of signal data from children with WPW who underwent ablation at two pediatric arrhythmia centers from 2008-2015. All patients with WPW ≤ 21 years who underwent invasive electrophysiology study and ablation with ablation signals available for review were included. Signals were excluded if temperature or power delivery was inadequate or lesion time was < 5 seconds. Ablation lesions were reviewed for each patient. Signals were classified as successful if there was loss of antegrade and retrograde accessory pathway (AP) conduction or unsuccessful if ablation did not eliminate AP conduction. Custom signal analysis software analyzed intracardiac electrograms for amplitudes, high and low frequency components, integrated area, and signal timing components to create a signal score. We validated the previously published signal score threshold 3.1 in this larger, more diverse cohort and explored additional scoring options. Logistic regression with lasso regularization using Youden's index criterion and a cost-benefit criterion to identify thresholds was considered as a refinement to this score. RESULTS: 347 signals (141 successful, 206 unsuccessful) in 144 pts were analyzed [mean age 13.2 ± 3.9 years, 96 (67%) male, 66 (45%) left sided APs]. The software correctly identified the signals as successful or unsuccessful in 276/347 (80%) at a threshold of 3.1. The performance of other thresholds did not significantly improve the predictive ability. A signal score threshold of 3.1 provided the following diagnostic accuracy for distinguishing a successful from unsuccessful signal: sensitivity 83%, specificity 77%, PPV 71%, NPV 87%. CONCLUSIONS: An automated signal analysis software tool reliably distinguished successful versus unsuccessful ablation electrograms in children with WPW when validated in a large, diverse cohort. Refining the tools using an alternative threshold and statistical method did not improve the original signal score at a threshold of 3.1. This software was effective across two centers and multiple operators and may be an effective tool for ablation of WPW.


Asunto(s)
Técnicas Electrofisiológicas Cardíacas , Procesamiento de Señales Asistido por Computador , Programas Informáticos , Síndrome de Wolff-Parkinson-White , Adolescente , Niño , Femenino , Humanos , Masculino , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Síndrome de Wolff-Parkinson-White/fisiopatología , Síndrome de Wolff-Parkinson-White/cirugía
3.
Pacing Clin Electrophysiol ; 40(7): 798-802, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28568013

RESUMEN

BACKGROUND: Ablation within the aortic cusp is safe and effective in adults. There are little data on aortic cusp ablation in the pediatric literature. We investigated the safety and efficacy of aortic cusp ablation in young patients. METHODS: A retrospective, descriptive study of aortic cusp ablation in five pediatric electrophysiology centers from 2008 to 2014 was performed. All patients <21 years of age who underwent ablation in the aortic cusps were included. Factors analyzed included patient demographics, procedural details, outcomes, and complications. RESULTS: Thirteen patients met inclusion criteria (median age 16 years [range 10-20.5] and median body surface area 1.58 m2 [range 1.12-2.33]). Substrates for ablation included: nine premature ventricular contractions or sustained ventricular tachycardia (69%), two concealed anteroseptal accessory pathways (APs) (15%), one Wolff-Parkinson-White with an anteroseptal AP (8%), and one ectopic atrial tachycardia (8%). Three-dimensional electroanatomic mapping in combination with fluoroscopy was used in 12/13 (92%) patients. Standard 4-mm-tip radiofrequency (RF) current was used in 11/13 (85%) and low-power irrigated-tip RF in 2/13 (15%). Angiography was used in 13/13 and intracardiac echocardiography was additionally utilized in 3/13 (23%). Ablation locations included: eight noncoronary (62%), three left (23%), and two right (15%) cusps. Ablation was acutely successful in all patients. At median follow-up of 20 months, there was one recurrence of PVCs (8%). There were no ablation-related complications and no valvular injuries observed. CONCLUSION: Arrhythmias originating from the coronary cusps in this series were successfully and safely ablated in young people without injury to the coronary arteries or the aortic valve.


Asunto(s)
Válvula Aórtica/cirugía , Arritmias Cardíacas/cirugía , Ablación por Catéter/métodos , Adolescente , Arritmias Cardíacas/fisiopatología , Mapeo del Potencial de Superficie Corporal , Niño , Técnicas Electrofisiológicas Cardíacas , Femenino , Fluoroscopía , Humanos , Masculino , Ondas de Radio , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA