Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Otol Neurotol ; 44(10): e739-e746, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37832576

RESUMEN

INTRODUCTION: A simultaneous recording of cervical and ocular vestibular evoked myogenic potential (sVEMP) to unilateral air-conducted (AC) stimulation reduces the test time and halves the sound load. MATERIALS AND METHODS: The sVEMP has been compared with the conventional sequential unilateral AC cervical and ocular VEMP in a consecutive cohort of 120 subjects attending the vestibular laboratory. The stimulus was a 500-Hz 6-ms tone burst, at 130 dB peSPL for sequential recordings but at 125 dB for the added sVEMP, for cumulative sound load containment. Amplitudes, latencies, and amplitude asymmetry ratios (ARs) were the parameters included in analysis. RESULTS: Relevant results were as follows: 1) significantly lower amplitudes in sVEMP versus VEMP (ocular recordings, median = 2.90 [IQR = 0-4.98] vs. 4.15 [1.73-8.98] µV, p < 0.001; cervical, 0.84 [0.30-1.69] vs. 1.36 [0.60-2.30], p < 0.001; electromyography scaled values); 2) 10% lower response rate at cervical recordings and 11% at ocular recordings in sVEMP, particularly in older subjects; 3) significant correlations between cervical amplitudes ( rs = 0.88, p < 0.001), ocular amplitudes ( rs = 0.71, p < 0.001), peak latencies ( rs = 0.36-0.67, p < 0.001), and ARs (ocular, rs = 0.56; cervical, rs = 68, p < 0.001); and 4) good agreement in pathological AR detection (cervical recordings, Cohen's κ = 0.649, p < 0.001; ocular, κ = 0.589, p < 0.001). DISCUSSION: AC sVEMP showed good correlation/agreement with sequential AC VEMP. Test time containment and halved sound load are clinical adds in sVEMP, opening to its use as laboratory standard. However, AC sVEMP presented reduced amplitudes and response rates, secondary to the reduced AC stimulation used in this study to allow checking of the null responses and the pathological ARs at AC sVEMP with conventional AC VEMP.


Asunto(s)
Ojo , Potenciales Vestibulares Miogénicos Evocados , Humanos , Anciano , Estimulación Acústica/métodos , Potenciales Vestibulares Miogénicos Evocados/fisiología , Sonido , Electromiografía
2.
Int J Audiol ; 54(10): 736-44, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26068536

RESUMEN

OBJECTIVE: The objective of this study is to describe the technical design and verify the technical performance of a new bone conduction implant (BCI) system. DESIGN: The BCI consists of an external audio processor and an implanted unit called the bridging bone conductor. These two units use an inductive link to communicate with each other through the intact skin in order to drive an implanted transducer. STUDY SAMPLE: In this study, the design of the full BCI system has been described and verified on a skull simulator and on real patients. RESULTS: It was found that the maximum output force (peak 107 dB re 1 µN) of the BCI is robust for skin thickness range of 2-8 mm and that the total harmonic distortion is below 8% in the speech frequency range for 70 dB input sound pressure level. The current consumption is 7.5 mA, which corresponds to 5-7 days use with a single battery. CONCLUSIONS: This study shows that the BCI is a robust design that gives a sufficiently high output and an excellent sound quality for the hearing rehabilitation of indicated patients.


Asunto(s)
Conducción Ósea , Audífonos , Pérdida Auditiva Sensorineural/rehabilitación , Personas con Deficiencia Auditiva/rehabilitación , Implantación de Prótesis , Percepción del Habla , Estimulación Acústica , Audiometría del Habla , Umbral Auditivo , Pérdida Auditiva Sensorineural/diagnóstico , Pérdida Auditiva Sensorineural/fisiopatología , Pérdida Auditiva Sensorineural/psicología , Humanos , Ensayo de Materiales , Modelos Anatómicos , Personas con Deficiencia Auditiva/psicología , Diseño de Prótesis , Procesamiento de Señales Asistido por Computador , Inteligibilidad del Habla
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA