Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Cardiovasc Electrophysiol ; 25(8): 803-812, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24628987

RESUMEN

INTRODUCTION: The optimal substrate ablation approach in patients with persistent atrial fibrillation (Per AF) remains unclear. This was a prospective randomized study comparing the efficacy of limited (continuous complex fractionated atrial electrogram, CFAE: <60 milliseconds) versus extensive (continuous CFAE plus variable CFAE: <120 milliseconds) atrial substrate modification in Per AF patients. METHODS AND RESULTS: We enrolled 120 Per AF patients in the study, and 30 patients with AF termination after pulmonary vein isolation (PVI) were excluded. In the remaining 90 patients, 45 were treated with limited approach (Group 1) and 45 with an extensive approach (Group 2). The end point of the study was the incidence of an atrial arrhythmia recurrence postblanking period. The patients were followed up for 15 months with 3-month clinical reviews, electrograms (ECGs), Holter recordings, and echocardiographic monitoring. Procedural AF termination and the single procedural efficacy were statistically comparable between the 2 groups (48.9% vs. 63.4% in Groups 1 and 2, respectively, P = 0.289). During the follow-up, patients who received limited ablation had a lower incidence of recurrent AFL (P = 0.04), and better reverse remodeling of the left atrium (LA, P = 0.04). After 2 procedures, the freedom from any atrial arrhythmia was better in Group 2 (62.2% vs. 87.8%, P = 0.009). Those with longstanding AF and a larger baseline LA size responded better to the extensive ablation. CONCLUSIONS: In the Per AF patients who failed to achieve AF termination after PVI alone, a specific atrial substrate modification approach targeting only continuous CFAEs could be considered as an initial ablation strategy.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Adulto , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Ecocardiografía Doppler , Ecocardiografía Transesofágica , Electrocardiografía Ambulatoria , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Recurrencia , Taiwán , Factores de Tiempo , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 23(11): 1155-62, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22702369

RESUMEN

INTRODUCTION: Pulmonary vein isolation (PVI) is the primary ablation therapy in patients with atrial fibrillation (AF). We hypothesized that high dominant frequency (DF) sites (AF nests during sinus rhythm [SR]) adjacent to the PV ostia are associated with the atrial substrate that maintains AF, and PVI incorporating the high-frequency AF nests may have a higher efficacy. METHODS AND RESULTS: In a prospective and randomized comparison, 126 symptomatic paroxysmal AF patients that underwent PVI were enrolled. We compared the efficacy of a modified PVI (ablation line: 1.0-1.5 cm from the PV ostium with encircling the AF nests [spectral analysis with DF >70 Hz during SR, Group II]) versus the anatomy-guided conventional PVI (Group I). In Group II, the DF value along the PV ostium was lower than 70 Hz after the PVI. The primary endpoint was the freedom from symptomatic atrial arrhythmias after a single procedure. We also followed the autonomic function by a time-domain analysis of the heart rate variability. In both groups, AF nests were observed and electric isolation was successfully obtained in all patients. With a mean duration of 16 ± 6.1 months of follow-up, Group II had a higher single procedure efficacy without drugs (78.7% vs 66.1%, log-rank test: P = 0.02), and fewer repeat procedures (6.6% vs 23%; P = 0.04), as compared to Group I. CONCLUSION: PVI incorporating the high frequency AF nests adjacent to the PV ostia had a better single procedure efficacy.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Potenciales de Acción , Adulto , Anciano , Análisis de Varianza , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Sistema Nervioso Autónomo/fisiopatología , Ablación por Catéter/efectos adversos , Distribución de Chi-Cuadrado , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Recurrencia , Taiwán , Factores de Tiempo , Resultado del Tratamiento
3.
Circ Arrhythm Electrophysiol ; 2(3): 233-41, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19808473

RESUMEN

BACKGROUND: There is a paucity of data regarding the mechanism of maintaining atrial fibrillation (AF) after pulmonary vein isolation (PVI) in patients with AF. The aim of this study was to examine the impact of circumferential PVI on the left atrial (LA) substrate characteristics. METHODS AND RESULTS: Seventy-two AF patients (age, 53+/-11 years) underwent mapping and catheter ablation using an NavX system. The biatrial characteristics such as the complex fractionated atrial electrograms (CFEs; based on fractionated intervals) and frequency analysis (based on dominant frequencies) were mapped before and after PVI. PVI with electric isolation was performed in all patients. In the 45 patients who did not respond to PVI, the continuous CFEs (>8 seconds, 18+/-18% and 12+/-17% of the LA sites, before and after PVI, respectively, P=0.02), degree of LA fractionation (mean fractionated interval: 75.6+/-14.3 msec versus 87.3+/-16.7 msec, P=0.001), and mean LA dominant frequencies (6.92+/-0.88 Hz versus 6.58+/-0.91 Hz, P=0.001) decreased after PVI. Complete PVI altered the distribution of the CFEs toward the LA anteroseptum, mitral annulus, and LA appendage regions. A persistent presence of continuous CFEs in the vicinity of the dominant frequencies sites (observed in 53% patients) correlated with a higher procedural AF termination rate for the CFE ablation (63% versus 23%, P<0.05). CONCLUSIONS: Complete PVI eliminated some CFEs in the LA and altered the distribution of the CFEs. The persistent presence of CFEs before and after PVI in the vicinity of the high frequency sites is important for AF maintenance after PVI.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Función del Atrio Izquierdo , Ablación por Catéter/métodos , Arteria Pulmonar/cirugía , Adulto , Técnicas Electrofisiológicas Cardíacas , Femenino , Estudios de Seguimiento , Atrios Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
4.
Heart Rhythm ; 6(3): 311-8, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19251203

RESUMEN

BACKGROUND: Termination of atrial fibrillation (AF) can be achieved by catheter ablation. It has been used as one of the procedural endpoints for AF ablation. OBJECTIVE: The purpose of this study was to investigate the factors that predict AF termination and the association with long-term outcomes. METHODS: Eighty-five consecutive AF patients (33 paroxysmal, 52 nonparoxysmal) underwent three-dimensional mapping and catheter ablation. A stepwise ablation approach included circumferential pulmonary vein (PV) isolation and left atrial (LA) linear ablation, followed by LA and right atrial (RA) electrogram-based (complex fractionated atrial electrogram) ablation. Clinical and electrophysiologic characteristics were assessed to evaluate the predictors of acute AF termination. RESULTS: In univariate analysis, a diagnosis of paroxysmal AF, shorter AF history, absence of history of heart failure, smaller LA diameter, longer postablation coronary sinus cycle length, lower LA and RA mean dominant frequencies, lower RA max dominant frequency, and higher LA voltage were related to acute termination of AF during ablation. Multivariate analysis showed that smaller LA diameter and lower preablation mean RA dominant frequency were independent predictors of AF termination. Multivariate analysis also showed that larger LA diameter and the presence of RA non-PV ectopy during the index procedure could predict late recurrence during long-term (13 +/- 8 months) follow-up. CONCLUSION: LA size and RA non-PV drivers are important for acute termination of AF and for long-term success. Careful selection of patients, extensive RA mapping, and LA ablation may enhance long-term ablation efficacy.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Cardioversión Eléctrica , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del Tratamiento
5.
Heart Rhythm ; 5(7): 968-74, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18598950

RESUMEN

BACKGROUND: Regions of rapid and multiple deflections can be identified with high dominant frequency (DF) during sinus rhythm (SR). These areas may play a role in the perpetuation of atrial fibrillation (AF) and indicate an atrial substrate abnormality. OBJECTIVE: The purpose of this study was to investigate the atrial substrate properties of the high-frequency sites in patients with paroxysmal AF. METHODS: Forty patients (52 +/- 12 years of age) with paroxysmal AF were studied using a three-dimensional mapping system. Spectral analysis was performed on the bipolar electrograms in the left atrium (LA) during SR. Overall, 7708 electrograms were analyzed, and the DFs higher than 70 Hz were labeled as abnormal. RESULTS: The regional distribution of the high-DF sites in the LA could be divided into two types. Type 1 includes high-DF sites existing only in the pulmonary veins (PVs; n = 19, 6.6 +/- 3.4 sites/patient). Type 2 includes high-DF sites in the LA or LA plus the PVs (n = 21, 11 +/- 5.6 sites/patient). In type 1, PV isolation (PVI) could eliminate the AF with negative AF inducibility testing after the PVI in 89% of patients. In type 2, additional LA substrate modification was needed in 81% of patients because sustained AF was induced after the PVI (P<.001, compared with type 1). Multivariate analysis showed that the lower mean voltage of the LA and high-frequency sites distribution both independently predicted a positive AF inducibility after the PVI (P<.05). CONCLUSIONS: Spectral analysis during SR can detect an abnormal atrial substrate. A regional distribution of the high-DF sites predicts the efficacy of the PVI.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal , Ablación por Catéter , Adulto , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad
6.
Heart Rhythm ; 5(3): 406-12, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18313599

RESUMEN

BACKGROUND: Temporal variation in complex fractionated atrial electrograms (CFAEs) exists during atrial fibrillation (AF). OBJECTIVE: This study sought to quantify the variation in CFAEs using a fractionation interval (FI) algorithm and to define the shortest optimal recording duration required to consistently characterize the magnitude of the fractionation. METHODS: Twenty-seven patients undergoing AF mapping in the left atrium were studied. The FI and frequency analysis were performed at each mapped site for recording durations of 1 to 8 seconds. The magnitude of the fractionation was quantified by the FI algorithm, which calculated the mean interval between multiple, discrete deflections during AF. The results from each duration were statistically compared with the maximal-duration recording, as a standard. The FI values were compared with the dominant frequency values obtained from the associated frequency spectra. RESULTS: The FIs obtained from recording durations between 5 and 8 seconds had a smaller variation in the FI (P < .05) and, for those sites with a FI < 50 ms, the fractionation was typically continuous. The fast-Fourier Transform spectra obtained from the CFAE sites with recording durations of >5 seconds harbored higher dominant frequency values than those with shorter recording durations (8.1 +/- 2.5 Hz vs. 6.8 +/- 0.98 Hz, P < .05). The CFAE sites with continuous fractionation were located within the pulmonary veins and their ostia in 77% of patients with paroxysmal AF, and in only 29% of patients with nonparoxysmal AF (P < .05). CONCLUSION: The assessment of fractionated electrograms requires a recording duration of > or =5 seconds at each site to obtain a consistent fractionation. Sites with the shortest FIs consistently identified sites with the fastest electrogram activity throughout the entire left atrium and pulmonary veins.


Asunto(s)
Algoritmos , Fibrilación Atrial/fisiopatología , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas/métodos , Análisis de Varianza , Fibrilación Atrial/cirugía , Ablación por Catéter , Distribución de Chi-Cuadrado , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Factores de Tiempo
7.
Europace ; 10(4): 438-43, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18319264

RESUMEN

AIMS: Fibrillatory waves observed in the surface electrograms may be a direct reflection of the electrophysiologic mechanism of the atrial fibrillation (AF). This study compared the fibrillatory waves in the surface ECG and the individual intracardiac mapping sites in different types of paroxysmal AF. METHODS AND RESULTS: Thirty patients with paroxysmal AF originating from the pulmonary veins (PVs) or superior vena cava (SVC) were enrolled. Frequency analysis was performed on the intracardiac electrograms recorded from various mapping sites in both atria sequentially with simultaneous surface electrogram recordings. The SVC-AF patients had a trend toward a higher DF in ECG lead V1 when compared with the PV-AF patients (7.35 +/- 2.09 vs. 5.89 +/- 0.79 Hz, P = 0.018). The mean dominant frequency (DF) of the LA mapping sites in the PV-AF patients was higher than that in the SVC-AF patients (7.06 +/- 0.66 vs. 6.13 +/- 0.96 Hz, P = 0.009), whereas the mean DF of the RA mapping sites was similar between the two groups (5.84 +/- 0.80 vs. 6.26 +/- 1.11 Hz, P = NS). The intra-class correlation coefficient (ICC) between the mean DF of the RA sites and V1 was higher (r = 0.21, P = 0.02) when compared with the mean DF of the LA sites (r = -0.007, P > 0.05). Furthermore, the maximal ICC was observed in the anterolateral RA free wall (r = 0.84, P < 0.001) and not the other anatomic sites of the RA and LA. CONCLUSION: The fibrillatory activity observed in ECG lead V1 correlated primarily with the activity of the anterolateral RA free wall and thus may be useful for detecting the AF source if it is close to that area.


Asunto(s)
Fibrilación Atrial/fisiopatología , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/fisiopatología , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Procesamiento de Señales Asistido por Computador , Vena Cava Superior/fisiopatología
8.
J Cardiovasc Electrophysiol ; 18(11): 1147-53, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17711441

RESUMEN

INTRODUCTION: Noncontact mapping (NCM) can record virtual unipolar electrograms (Egs) from multiple sites simultaneously; therefore, it has the potential to perform simultaneous frequency mapping during atrial fibrillation (AF). The aim of this study was to validate the frequency spectra of the noncontact unipolar Egs in both atria. METHODS: This study enrolled 12 patients (age = 61 +/- 16 years) with paroxysmal or persistent AF who underwent catheter ablation guided by NCM. Noncontact and contact unipolar Egs were recorded simultaneously. The cross-correlation of the Eg morphology, activation time difference of the time-domain signals, and resultant frequency spectra were compared via dominant frequency (DF) and magnitude-squared coherence (MSC). RESULTS: A total of 159 sites were analyzed during AF. The variables that independently predicted a higher correlation between the contact and noncontact electrogram morphology were a smaller activation timing difference P < 0.01), smaller distance of the mapping sites to the array center (P = 0.01), and higher atrial voltage (P = 0.03). However, the average MSC of the frequency band within the physiologic range of AF (2 to 15 Hz) was only affected by the activation timing difference (P = 0.002). The DF value between the contact and noncontact unipolar signals correlated well with each other throughout the right atria and left atria in 94% of the mapping sites (r = 0.87, P < 0.001). CONCLUSION: The accuracy of the noncontact unipolar Eg morphology decreased when the mapping sites harbored a smaller atrial voltage and longer distance to the array center. The DF difference between the contact and noncontact unipolar Eg was not affected by the distance to the array center.


Asunto(s)
Fibrilación Atrial/diagnóstico , Técnicas Electrofisiológicas Cardíacas/métodos , Adulto , Anciano , Fibrilación Atrial/fisiopatología , Técnicas Electrofisiológicas Cardíacas/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
9.
J Am Coll Cardiol ; 47(7): 1401-7, 2006 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-16580528

RESUMEN

OBJECTIVES: This study sought to investigate the regional frequency distribution from multiple bi-atrial sites in different types of paroxysmal atrial fibrillation (AF). BACKGROUND: A previous study showed a left atrium (LA) to right atrium (RA) frequency gradient in patients with paroxysmal AF. METHODS: Forty-four patients (age = 60 +/- 16, male patients = 27) with paroxysmal AF originating from the pulmonary veins (PVs) (n = 31) or superior vena cava (SVC) (n = 13) were included. Frequency analysis was performed on the intracardiac electrograms (7 s, 1 kHz/channel) recorded from PV, posterior LA, coronary sinus (CS), posterolateral RA, and SVC. The largest peak frequency was identified as the dominant frequency (DF). RESULTS: In the PV-AF patients, there was a frequency gradient from the PV ostium to the LA, RA, and SVC (8.5 +/- 3.3 Hz vs. 5.9 +/- 1.1 Hz vs. 5.2 +/- 0.85 Hz vs. 5.5 +/- 0.48 Hz, respectively, p < 0.001). The highest DFs were mostly located at the arrhythmogenic PV ostium (58%). The DFs of the arrhythmogenic PV and PV ostium were significantly higher than those of the non-arrhythmogenic PVs and PV ostia (p < 0.05). In the SVC-AF patients, there was a frequency gradient from the SVC to the RA, LA, and PV (8.0 +/- 2.4 Hz vs. 5.9 +/- 1.1 Hz vs. 5.9 +/- 0.7 Hz vs. 5.8 +/- 0.7 Hz, respectively, p = 0.001). The highest DFs were mostly located inside the SVC (77%) instead of the SVC ostium (as compared with PV-AF patients, p = 0.035). CONCLUSIONS: The location of the highest DF depended on the arrhythmogenic PV or SVC. A frequency gradient was present between the arrhythmogenic thoracic vein and atrium in all patients.


Asunto(s)
Fibrilación Atrial/clasificación , Fibrilación Atrial/fisiopatología , Función Atrial , Técnicas Electrofisiológicas Cardíacas , Fibrilación Atrial/diagnóstico , Vasos Coronarios/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Factores de Tiempo , Vena Cava Superior/fisiopatología
10.
J Digit Imaging ; 18(1): 28-36, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15937718

RESUMEN

This article demonstrates a gateway system for converting image fusion results to digital imaging and communication in medicine (DICOM) objects. For the purpose of standardization and integration, we have followed the guidelines of the Integrated Healthcare Enterprise technical framework and developed a DICOM gateway. The gateway system combines data from hospital information system, image fusion results, and the information generated itself to constitute new DICOM objects. All the mandatory tags defined in standard DICOM object were generated in the gateway system. The gateway system will generate two series of SOP instances of each PET-MR fusion result; SOP (Service Object Pair) one for the reconstructed magnetic resonance (MR) images and the other for position emission tomography (PET) images. The size, resolution, spatial coordinates, and number of frames are the same in both series of SOP instances. Every new generated MR image exactly fits with one of the reconstructed PET images. Those DICOM images are stored to the picture archiving and communication system (PACS) server by means of standard DICOM protocols. When those images are retrieved and viewed by standard DICOM viewing systems, both images can be viewed at the same anatomy location. This system is useful for precise diagnosis and therapy.


Asunto(s)
Redes de Comunicación de Computadores , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Integración de Sistemas , Sistemas de Administración de Bases de Datos , Humanos , Almacenamiento y Recuperación de la Información , Sistemas de Información Radiológica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA