Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Interv Card Electrophysiol ; 63(2): 259-266, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33638777

RESUMEN

PURPOSE: A significant proportion of patients undergoing catheter ablation for atrial fibrillation (AF) experience arrhythmia recurrence. This is mostly due to pulmonary vein reconnection (PVR). Whether mapping using High-Density Wave (HDW) technology is superior to standard bipolar (SB) configuration at detecting PVR is unknown. We aimed to evaluate the efficacy of HDW technology compared to SB mapping in identifying PVR. METHODS: High-Density (HD) multipolar Grid catheters were used to create left atrial geometries and voltage maps in 36 patients undergoing catheter ablation for AF (either due to recurrence of an atrial arrhythmia from previous AF ablation or de novo AF ablation). Nineteen SB maps were also created and compared. Ablation was performed until pulmonary vein isolation was achieved. RESULTS: Median time of mapping with HDW was 22.3 [IQR: 8.2] min. The number of points collected with HDW (13299.6±1362.8 vs 6952.8±841.9, p<0.001) and used (2337.3±158.0 vs 1727.5±163.8, p<0.001) was significantly higher compared to SB. Moreover, HDW was able to identify more sleeves (16 for right and 8 for left veins), where these were confirmed electrically silent by SB, with significantly increased PVR sleeve size as identified by HDW (p<0.001 for both right and left veins). Importantly, with the use of HDW, the ablation strategy changed in 23 patients (64% of targeted veins) with a significantly increased number of lesions required as compared to SB for right (p=0.005) and left veins (p=0.003). CONCLUSION: HDW technology is superior to SB in detecting pulmonary vein reconnections. This could potentially result into a significant change in ablation strategy and possibly to increased success rate following pulmonary vein isolation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Catéteres , Técnicas Electrofisiológicas Cardíacas , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
2.
Pacing Clin Electrophysiol ; 44(2): 318-326, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33377500

RESUMEN

OBJECTIVES: To study how left atrial appendage electrical isolation (LAAEI) impacts atrial dominant frequency (DF) in patients with long-standing persistent atrial fibrillation (LSPAF). BACKGROUND: LAAEI is associated with a high probability of freedom from atrial fibrillation (AF) and spectral analysis may identify high-frequency sources. How LAAEI impacts the AF dynamics and the subgroup of LSPAF patients in whom LAAEI would be most beneficial, is unclear. METHODS: Twenty patients with LSPAF were included in the study. Fast Fourier transforms (FFT) were performed on atrial electrograms recorded from 13 sites in the LA and RA. The highest peak frequency was defined as DF. RESULTS: There was no significant difference in DF between atrial sites except for at the superior vena cava which had the lowest DF at baseline. Stepwise ablation consisting of circumferential pulmonary vein isolation and a linear ablation set of mitral isthmus and roof significantly reduced the DF within the coronary sinus (CS) (5.93 ± 0.98 Hz vs. 5.09 ± 0.72 Hz, p < .05) and the LA posterior wall (LApos) (6.26 ± 0.92 Hz vs. 5.43 ± 0.98 Hz, p < .01). LAAEI preferentially further decreased the DF at the LApos (p < .01), but not at the CS. In cases where there was < 13.6% reduction in the DF of the LApos following the stepwise ablation, the addition of LAAEI was associated with an increased restoration of sinus rhythm (55%, p < .05). CONCLUSION: LAAEI in addition to stepwise ablation results in further reduction of the DF in the LApos, which is associated with acute termination of AF and favorable ablation outcome.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Anciano , Fibrilación Atrial/fisiopatología , Procedimientos Quirúrgicos Cardíacos/métodos , Protocolos Clínicos , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA