1.
Exp Eye Res ; 226: 109349, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36516904

RESUMEN

Recently, we proposed a method to assess cell-specific retinal functions based on the frequency-dependent responses to sinusoidal transcorneal electrostimulation. In this study, we evaluated the alterations in responsiveness in achromatopsia patients to explore the frequency-selectivity of photoreceptors. The electrical stimulation was applied to one eye of genetically confirmed achromatopsia patients via corneal electrodes. The stimulus was composed of amplitude-modulated sine waves with variable carrier frequencies (4-30 Hz) and a steady low-frequency envelope. The retinal responsiveness across the spectrum was calculated based on the velocity and the synchronicity of the electrically evoked pupillary oscillations. Achromats displayed a characteristic peak in responsiveness in the 6-10 Hz range. In contrast, stimulus frequencies above 16 Hz elicited only weak pupil responses and weak phosphenes. Compared to the tuning curve of the healthy retina, responses to low-frequency stimulation appear to reflect mainly rod activation while higher frequencies seem to activate cones. The possibility to examine cell-specific retinal functions independently from their responses to light may improve our understanding of the structural changes in the retina induced by gene therapy.


Asunto(s)
Defectos de la Visión Cromática , Humanos , Retina/fisiología , Células Fotorreceptoras Retinianas Conos/fisiología , Estimulación Eléctrica/métodos , Estimulación Luminosa/métodos
2.
Exp Eye Res ; 222: 109185, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35850172

RESUMEN

Studies on the electrical excitability of retinal neurons show that photoreceptors and other cell types can be selectively activated by distinct stimulation frequencies in vitro. Yet, this principle still needs to be validated in humans in vivo. As a first step, this study explored the frequency preferences of human rods by means of transcorneal electrostimulation (TES), using the electrically-elicited pupillary responses (EEPRs) as an objective readout. The stimulation paradigm contained a 1.2 Hz sinusoidal envelope, which was superimposed on variable carrier frequencies (4-30 Hz). These currents were delivered to one of the participant's eyes via a corneal electrode and consensual pupillary reactions were recorded from the contralateral eye. The responsiveness of the retina at each frequency was assessed based on the EEPR dynamics. Differences between healthy participants and patients with retinitis pigmentosa were evaluated to identify the preferred frequency range of rods. The responsiveness of healthy individuals revealed a clear peak around 6-8 Hz. In contrast, the pupillary responses of patients were significantly reduced in the lower frequency range. These findings suggest that the responses in this frequency bin were selectively mediated by rods. This work provides evidence that different retinal cell types can be selectively activated via TES in vivo, and that this effect can be captured noninvasively using EEPRs. This knowledge may be exploited for the diagnostics and therapy of retinal diseases, e.g., to design cell-specific functional tests for the degenerating retina, or to optimize stimulation paradigms which are currently used by retinal prostheses.


Asunto(s)
Córnea , Retinitis Pigmentosa , Córnea/fisiología , Estimulación Eléctrica , Humanos , Retina/metabolismo , Células Fotorreceptoras Retinianas Bastones , Retinitis Pigmentosa/metabolismo
3.
Exp Eye Res ; 176: 210-218, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30003883

RESUMEN

The purpose was to evaluate retinal function by measuring pupillary responses to sinusoidal transcorneal electrostimulation in healthy young human subjects. This work also translates data from analogous in vitro experiments and connects it to the pupillary responses obtained in human experiments. 14 healthy human subjects participated (4 males, 10 females); for the in vitro experiments, two male healthy mouse retinas (adult wild-type C57B/6J) were used. Pupillary responses to sinusoidal transcorneal electrostimulation of varying stimulus carrier frequencies (10, 20 Hz; envelope frequency constantly kept at 1.2 Hz) and intensities (10, 20, 50 µA) were recorded and compared with those obtained with light stimulation (1.2 Hz sinusoidal blue, red light). A strong correlation between the sinusoidal stimulation (electrical as well as light) and the pupillary sinusoidal response was found. The difference between the lag of electrical and light stimulation allowed the estimation of an intensity threshold for pupillary responses to transcorneal electrostimulation (mean ±â€¯SD: 30 ±â€¯10 µA (10 Hz); 38 ±â€¯10 µA (20 Hz)). A comparison between the results of the two stimulation frequencies showed a not statistically significant smaller lag for 10 Hz (10 Hz: 633 ±â€¯90 ms; 20 Hz: 725 ±â€¯178 ms; 50 µA intensity). Analogous in vitro experiments on murine retinas indicated a selective stimulation of photoreceptors and bipolar cells (lower frequencies) and retinal ganglion cells (higher frequencies) and lower stimulation thresholds for the retinal network with sinusoidal compared to pulsatile stimulation - emphasizing that sinusoidal waveforms are well-suited to our purposes. We demonstrate that pupillary responses to sinusoidal transcorneal electrostimulation are measurable as an objective marker in healthy young subjects, even at very low stimulus intensities. By using this unique approach, we unveil the potential for an estimation of the individual intensity threshold and a selective activation of different retinal cell types in humans by varying the stimulation frequency. This technique may have broad clinical utility as well as specific relevance in the monitoring of patients with hereditary retinal disorders, especially as implemented in study protocols for novel therapies, e.g. retinal prostheses or gene therapies.


Asunto(s)
Estimulación Eléctrica , Fosfenos/fisiología , Reflejo Pupilar/fisiología , Retina/fisiología , Percepción Visual/fisiología , Adulto , Animales , Córnea/fisiología , Femenino , Voluntarios Sanos , Humanos , Masculino , Ratones , Ratones Endogámicos C57BL , Estimulación Luminosa , Células Fotorreceptoras de Vertebrados/fisiología , Células Bipolares de la Retina/fisiología , Células Ganglionares de la Retina/fisiología
4.
Acta Ophthalmol ; 95(4): e261-e269, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27683070

RESUMEN

PURPOSE: To analyse pupil responses to specific chromatic stimuli in patients with advanced retinitis pigmentosa (RP) to ascertain whether chromatic pupillography can be used as an objective marker for residual retinal function. To examine correlations between parameters of the pupil response and the perception threshold of electrically evoked phosphenes. METHODS: Chromatic pupillography was performed in 40 patients with advanced RP (visual acuity < 0.02 or visual field ≤5°, non-recordable ERGs) and 40 age-matched healthy subjects. Pupil responses to full-field red (605 nm) and blue (420 nm) stimuli of 28 lx corneal illumination were recorded and analysed for two stimulus durations (1 and 4 seconds). The perception threshold of phosphenes to transcorneal electrostimulation was ascertained and correlated to the pupil responses and visual acuity. RESULTS: Patients with RP showed significantly reduced pupil responses to red and blue stimuli compared with the controls. With red stimuli, pupillary escape could be observed; blue stimuli resulted in a well-preserved postillumination pupil response. Phosphene thresholds were significantly increased in patients with RP and correlated with the parameters of the pupil response if all subjects were considered. Within the RP group alone, this relationship was less pronounced and statistically not significant. CONCLUSIONS: Chromatic pupillography demonstrated a significant decrease in outer retinal photoreceptor responses but a persisting and disinhibited intrinsic photosensitive retinal ganglion cell function in advanced RP. These phenomena may be useful as an objective marker for the efficacy of any interventional treatment for hereditary retinal diseases as well as for the selection of suitable patients for an electronic retinal implant.


Asunto(s)
Técnicas de Diagnóstico Oftalmológico , Estimulación Eléctrica/métodos , Células Fotorreceptoras de Vertebrados/fisiología , Reflejo Pupilar/fisiología , Células Ganglionares de la Retina/fisiología , Retinitis Pigmentosa/fisiopatología , Agudeza Visual , Córnea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estimulación Luminosa , Reproducibilidad de los Resultados , Retinitis Pigmentosa/diagnóstico