Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Graefes Arch Clin Exp Ophthalmol ; 257(2): 339-347, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30483950

RESUMEN

PURPOSE: To analyze the longitudinal change in Bruch's membrane opening minimal rim width (BMO-MRW) and circumpapillary retinal nerve fiber layer (RNFL) thickness using spectral domain optical coherence tomography (SD-OCT) after glaucoma surgery via ab-interno trabeculectomy in adult glaucoma patients. METHODS: Retrospective audit of 65 eyes of 65 participants undergoing ab-interno trabeculectomy using electroablation of the trabecular meshwork. In 53 eyes, surgery was combined with phacoemulsification and posterior chamber lens implantation. Pre- and postoperative SD-OCT examinations of the optic nerve head (ONH), intraocular pressure (IOP), and visual field data were analyzed. Longitudinal change in morphometric SD-OCT parameters of the ONH was compared and correlated to change in IOP and visual field function. RESULTS: BMO-MRW increased significantly between baseline (BL) and follow-up (FU) within the first 6 months after surgery (BL = 167.85 ± 90 µm; FU = 175.59 ± 89 µm; p = 0.034). This increase correlated with postoperative lowering of IOP (rho = - 0.41; p = 0.016). Nine months after surgery (range, 7-12 months), there was no significant change in BMO-MRW (BL = 196.79 ± 79; FU = 196.47 ± 85 µm; p = 0.95), while in later follow-up, a decrease of BMO-MRW was found (BL = 175.18 ± 78; FU = 168.65 ± 72; p = 0.05). RNFL thickness was unchanged in early (p > 0.16) and significantly decreased in later follow-up (p = 0.009). Mean deviation (MD) of visual field function did not show a significant change before and after surgery. CONCLUSION: Electroablative ab-interno trabeculectomy leads to a significant transient mild increase in BMO-MRW. This increase was shown to correlate with IOP lowering. Significant loss of BMO-MRW in later follow-up may reflect insufficient IOP reduction by surgery. The parameters RNFL thickness and MD seem less impacted directly by surgery.


Asunto(s)
Lámina Basal de la Coroides/patología , Glaucoma/cirugía , Presión Intraocular/fisiología , Disco Óptico/patología , Tomografía de Coherencia Óptica/métodos , Trabeculectomía/métodos , Campos Visuales/fisiología , Técnicas de Ablación/métodos , Anciano , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Glaucoma/diagnóstico , Glaucoma/fisiopatología , Humanos , Masculino , Pronóstico , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA