Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Métodos Terapéuticos y Terapias MTCI
Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Mol Pharm ; 20(3): 1696-1708, 2023 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-36707500

RESUMEN

Despite the great promise of antibiotic therapy in wound infections, antibiotic resistance stemming from frequent dosing diminishes drug efficacy and contributes to recurrent infection. To identify improvements in antibiotic therapies, new antibiotic delivery systems that maximize pharmacological activity and minimize side effects are needed. In this study, we developed elastin-like peptide and collagen-like peptide nanovesicles (ECnVs) tethered to collagen-containing matrices to control vancomycin delivery and provide extended antibacterial effects against methicillin-resistant Staphylococcus aureus (MRSA). We observed that ECnVs showed enhanced entrapment efficacy of vancomycin by 3-fold as compared to liposome formulations. Additionally, ECnVs enabled the controlled release of vancomycin at a constant rate with zero-order kinetics, whereas liposomes exhibited first-order release kinetics. Moreover, ECnVs could be retained on both collagen-fibrin (co-gel) matrices and collagen-only matrices, with differential retention on the two biomaterials resulting in different local concentrations of released vancomycin. Overall, the biphasic release profiles of vancomycin from ECnVs/co-gel and ECnVs/collagen more effectively inhibited the growth of MRSA for 18 and 24 h, respectively, even after repeated bacterial inoculation, as compared to matrices containing free vancomycin, which just delayed the growth of MRSA. Thus, this newly developed antibiotic delivery system exhibited distinct advantages for controlled vancomycin delivery and prolonged antibacterial activity relevant to the treatment of wound infections.


Asunto(s)
Staphylococcus aureus Resistente a Meticilina , Infección de Heridas , Humanos , Vancomicina , Antibacterianos/farmacología , Liposomas/farmacología , Pruebas de Sensibilidad Microbiana , Colágeno/farmacología
2.
Acta Biomater ; 103: 115-128, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31843720

RESUMEN

Wound infections are a significant clinical problem affecting millions of people worldwide. Topically applied antibacterial formulations with longer residence time and controlled antimicrobial release would offer significant benefits for improved prevention and treatment of infected wounds. In this study, we developed collagen mimetic peptide (CMP) tethered vancomycin (Van)-containing liposomes (Lipo) (CMP-Van-Lipo) hybridized to collagen-based hydrogels ('co-gels,' e.g., collagen/fibrin combination hydrogels) for the treatment of methicillin-resistant Staphylococcus aureus (MRSA) infections in vitro and in vivo. Tethering CMP-Van-Lipo nanostructures to co-gels enabled sustained Van release and enhanced in vitro antibacterial effects against MRSA as compared to Van loaded co-gels or Van-Lipo loaded co-gels following multiple fresh bacterial inoculations over a period of 48 h. These results were successfully translated in vivo wherein MRSA infected wounds were effectively treated with CMP-Van-Lipo loaded co-gels for up to 9 days, whereas the activity of Van loaded co-gels and Van-Lipo loaded co-gels were limited to <2 days. Moreover, CMP-Van-Lipo retained in vivo antibacterial activity even after re-inoculation with bacteria; however, Van loaded co-gels and Van-Lipo loaded co-gels allowed significant bacterial growth demonstrating their limited efficacy. Altogether, these results provide proof-of-concept that CMP-Van-Lipo loaded co-gels can be effective topical formulations for preventive treatment of MRSA wound infections. STATEMENT OF SIGNIFICANCE: Current topical antimicrobial formulations (e.g., creams, gels, and ointments) do not control release, leaving antimicrobial concentrations either too high or too low at different time points, and provoking the development of antibacterial resistance and recurrence of wound infections. Here, collagen mimetic peptides (CMPs) were used to stably hybridize vancomycin-containing liposomal nanocarriers (CMP-Van-Lipo) within collagen-fibrin co-gels via triple-helical integration with collagen, enabling control over Van release for prolonged time periods and minimizing the adverse effects of the Lipo formulations on fibroblast cell viability in the wound bed. The CMP-Van-Lipo loaded co-gel's higher antibacterial effects in vitro were successfully translated in vivo for treatment of MRSA-infected mouse wounds, and thus the co-gels can be a potentially translatable treatment for improved clinical wound management.


Asunto(s)
Materiales Biomiméticos/uso terapéutico , Colágeno/química , Control de Infecciones , Péptidos/química , Andamios del Tejido/química , Vancomicina/uso terapéutico , Infección de Heridas/tratamiento farmacológico , Animales , Antibacterianos/farmacología , Bovinos , Supervivencia Celular/efectos de los fármacos , Modelos Animales de Enfermedad , Liberación de Fármacos , Geles , Liposomas , Masculino , Staphylococcus aureus Resistente a Meticilina/efectos de los fármacos , Ratones , Ratones Endogámicos BALB C , Pruebas de Sensibilidad Microbiana , Células 3T3 NIH , Ratas Sprague-Dawley , Piel/efectos de los fármacos , Piel/microbiología , Piel/patología , Vancomicina/farmacología , Infección de Heridas/microbiología , Infección de Heridas/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA