Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Cochlear Implants Int ; 12(4): 194-204, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22251806

RESUMEN

Efficacy of the SPEAK and ACE coding strategies was compared with that of a new strategy, MP3000™, by 37 European implant centers including 221 subjects. The SPEAK and ACE strategies are based on selection of 8-10 spectral components with the highest levels, while MP3000 is based on the selection of only 4-6 components, with the highest levels relative to an estimate of the spread of masking. The pulse rate per component was fixed. No significant difference was found for the speech scores and for coding preference between the SPEAK/ACE and MP3000 strategies. Battery life was 24% longer for the MP3000 strategy. With MP3000 the best results were found for a selection of six components. In addition, the best results were found for a masking function with a low-frequency slope of 50 dB/Bark and a high-frequency slope of 37 dB/Bark (50/37) as compared to the other combinations examined of 40/30 and 20/15 dB/Bark. The best results found for the steepest slopes do not seem to agree with current estimates of the spread of masking in electrical stimulation. Future research might reveal if performance with respect to SPEAK/ACE can be enhanced by increasing the number of channels in MP3000 beyond 4-6 and it should shed more light on the optimum steepness of the slopes of the masking functions applied in MP3000.


Asunto(s)
Implantes Cocleares , Procesamiento de Señales Asistido por Computador , Estimulación Acústica/instrumentación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Implantación Coclear/instrumentación , Electrónica , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enmascaramiento Perceptual , Psicofísica , Procesamiento de Señales Asistido por Computador/instrumentación , Análisis Espectral , Acústica del Lenguaje , Telemetría/métodos , Adulto Joven
2.
Int J Audiol ; 49(9): 657-66, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20583945

RESUMEN

Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rates tended to give lower scores. However, there were no significant differences between the word scores across subjects if collected at the individually preferred pulse rate. High pulse rates were preferred when the post-implantation threshold was low.


Asunto(s)
Percepción Auditiva , Implantes Cocleares , Corrección de Deficiencia Auditiva , Pérdida Auditiva Sensorineural/rehabilitación , Personas con Deficiencia Auditiva/rehabilitación , Procesamiento de Señales Asistido por Computador , Percepción del Habla , Estimulación Acústica , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Audiometría del Habla , Umbral Auditivo , Estimulación Eléctrica , Europa (Continente) , Pérdida Auditiva Sensorineural/psicología , Humanos , Percepción Sonora , Persona de Mediana Edad , Personas con Deficiencia Auditiva/psicología , Diseño de Prótesis , Ajuste de Prótesis , Índice de Severidad de la Enfermedad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA