Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Más filtros

Métodos Terapéuticos y Terapias MTCI
Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Neurol ; 22(1): 48, 2022 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-35139806

RESUMEN

BACKGROUND: By definition, the background EEG is normal in juvenile myoclonic epilepsy (JME) patients and not accompanied by other developmental and cognitive problems. However, some recent studies using quantitative EEG (qEEG) reported abnormal changes in the background activity. QEEG investigation in patients undergoing anticonvulsant treatment might be a useful approach to explore the electrophysiology and anticonvulsant effects in JME. METHODS: We investigated background EEG activity changes in patients undergoing valproic acid (VPA) treatment using qEEG analysis in a distributed source model. In 17 children with JME, non-parametric statistical analysis using standardized low-resolution brain electromagnetic tomography was performed to compare the current density distribution of four frequency bands (delta, theta, alpha, and beta) between untreated and treated conditions. RESULTS: VPA reduced background EEG activity in the low-frequency (delta-theta) bands across the frontal, parieto-occipital, and limbic lobes (threshold log-F-ratio = ±1.414, p < 0.05; threshold log-F-ratio= ±1.465, p < 0.01). In the delta band, comparative analysis revealed significant current density differences in the occipital, parietal, and limbic lobes. In the theta band, the analysis revealed significant differences in the frontal, occipital, and limbic lobes. The maximal difference was found in the delta band in the cuneus of the left occipital lobe (log-F-ratio = -1.840) and the theta band in the medial frontal gyrus of the left frontal lobe (log-F-ratio = -1.610). CONCLUSIONS: This study demonstrated the anticonvulsant effects on the neural networks involved in JME. In addition, these findings suggested the focal features and the possibility of functional deficits in patients with JME.


Asunto(s)
Epilepsia Mioclónica Juvenil , Ácido Valproico , Encéfalo/diagnóstico por imagen , Niño , Electroencefalografía , Fenómenos Electromagnéticos , Lóbulo Frontal , Humanos , Epilepsia Mioclónica Juvenil/tratamiento farmacológico , Tomografía , Ácido Valproico/uso terapéutico
2.
J Cosmet Laser Ther ; 22(4-5): 185-189, 2020 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-33070649

RESUMEN

A novel photopneumatic (PPX) technology, combining blue light-emitting diode (LED) and broadband intense pulsed light (IPL) with vacuum pressure, was developed for the treatment of acne vulgaris (AV). In this study, we enrolled 50 patients with mild to moderate AV. Five successive treatments were performed on one side of the face with a combined PPX device, and the opposite side was treated with only IPL with the same fluences at 2-week intervals. Clinical improvement was evaluated by inflammatory and non-inflammatory acne lesion counts. Additionally, patient self-assessment scores were assessed. The results showed that inflammatory and non-inflammatory acne lesion counts were significantly improved on both sides of the face after treatment (p < .001, p = .001, respectively). Both inflammatory and non-inflammatory lesion counts were significantly reduced on the side treated with PPX when compared to the side treated with IPL alone (p = .008, p = .045, respectively). Thirty-eight of 44 patients reported slight to moderate improvement on the patient self-assessment score. No significant side effect was observed during the study periods.In conclusion, PPX therapy is an effective and safe modality to treat mild to moderate AV. This study shows that PPX therapy has superior efficacy for the treatment of AV compared to IPL monotherapy.


Asunto(s)
Acné Vulgar , Fotoquimioterapia , Fototerapia , Acné Vulgar/tratamiento farmacológico , Humanos , Resultado del Tratamiento , Vacio
3.
JACC Clin Electrophysiol ; 5(11): 1253-1261, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31753429

RESUMEN

OBJECTIVES: This study explored whether complete electrical isolation of the left atrial (LA) posterior wall improves the rhythm outcome of catheter ablation of persistent atrial fibrillation (AF). BACKGROUND: Although the STAR AF2 (Substrate and Trigger Ablation for Reduction of Atrial Fibrillation Trial Part II) proved no additional benefit of empirical extra-pulmonary vein (PV) LA ablation, the long-term recurrence rate after circumferential PV isolation (CPVI) alone remains high. METHODS: We randomly assigned 217 patients with persistent AF (83.1% men, age 58.7 ± 10.8 years, 73.3% long-standing persistent AF) to ablation with CPVI alone (CPVI group) or CPVI with a POsterior wall Box Isolation (POBI group). The endpoint of the POBI group was the elimination of the posterior atrial potentials by roof and posterior inferior lines and touch-up focal ablation. RESULTS: After a mean follow-up of 16.2 ± 8.8 months, the clinical recurrence rate did not significantly differ between the 2 groups (23.8% vs. 26.5%; p = 0.779) in the CPVI and POBI groups. The recurrence rate for atrial tachycardias (16.0% vs. 11.1%; p = 0.913) and cardioversion rates (6.7% vs. 13.7%; p = 0.093) to control clinical recurrences also did not significantly differ between the 2 groups. At the final follow-up, sinus rhythm was maintained without antiarrhythmic drug in 50.5% and 55.9% in the CPVI and POBI groups, respectively (p = 0.522). No significant difference was found in the major complication rates between the 2 groups, but the total ablation time was significantly longer in the POBI group (4,289 ± 1,837 s vs. 5,365 ± 2,358 s; p < 0.001). CONCLUSIONS: In patients with persistent AF, an empirical complete POBI did not improve the rhythm outcome of catheter ablation or influence the type of recurrent atrial arrhythmia. (Comparison of Circumferential Pulmonary Vein Isolation Alone Versus Linear Ablation in Addition to Circumferential Pulmonary Vein Isolation for Catheter Ablation in Persistent Atrial Fibrillation: Prospective Randomized Controlled Trial; NCT02721121).


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Atrios Cardíacos/cirugía , Venas Pulmonares/cirugía , Anciano , Antiarrítmicos/uso terapéutico , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias/epidemiología , Recurrencia , Resultado del Tratamiento
4.
Europace ; 21(12): 1824-1832, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31578551

RESUMEN

AIMS: The impact of persistent left superior vena cava (PLSVC) in atrial fibrillation (AF) patients undergoing radiofrequency catheter ablation (RFCA) is not well known. We performed this analysis to evaluate the electrophysiological characteristics of PLSVC and its role in triggering and maintaining AF. METHODS AND RESULTS: Patients with AF referred to two tertiary hospitals were screened and patients with PLSVC in pre-RFCA imaging studies were enrolled. Among 3967 patients, PLSVC was present in 36 patients (0.9%). There were four morphological types of PLSVC: type 1, atresia of the right superior vena cava (SVC) (n = 2); type 2A, dual SVCs with an anastomosis between right and left SVCs (n = 15); type 2B, dual SVCs without an anastomosis (n = 16); type 3, PLSVC draining into the left atrium (LA; n = 2); and unclassified in one patient. Thirty-two patients underwent RFCA and electrophysiology study focusing on PLSVC: PLSVC was the trigger of AF in 48.4% of patients and the driver of AF in 46.9% of patients. Cumulatively, PLSVC was a trigger or driver of AF in 22 patients (68.8%). Whether to ablate PLSVC was determined by the results of electrophysiology study, and no significant difference in the late recurrence rate was observed between patients who did and did not have either trigger or driver from PLSVC. CONCLUSION: Pre-RFCA cardiac imaging revealed PLSVC in 0.9% of AF patients. This study demonstrated that PLSVC has an important role in initiating and maintaining AF in substantial proportion of patients. Electrophysiology study focusing on PLSVC can help to decide whether to ablate PLSVC.


Asunto(s)
Fibrilación Atrial/fisiopatología , Vena Cava Superior Izquierda Persistente/fisiopatología , Adulto , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Vena Cava Superior Izquierda Persistente/complicaciones , Vena Cava Superior Izquierda Persistente/diagnóstico por imagen , Vena Cava Superior Izquierda Persistente/cirugía , Flebografía , Recurrencia , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/cirugía
6.
Europace ; 21(4): 598-606, 2019 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-30649276

RESUMEN

AIMS: Findings regarding efficacy of substrate modification for non-paroxysmal atrial fibrillation (AF) are inconsistent. We prospectively compared clinical outcomes of complex fractionated atrial electrogram (CFAE)-guided focal ablation (CFA) and CFAE-guided linear ablation (CLA) in patients with non-paroxysmal AF. METHODS AND RESULTS: We randomized 150 patients with non-paroxysmal AF into CFA and CLA groups in a 1:1 ratio. Complex fractionated atrial electrogram distribution was evaluated using an automated algorithm of a three-dimensional mapping system. After pulmonary vein isolation (PVI), CFAE-guided ablation was performed in the left atrium and then in the right atrium (RA). When compared with conventional CFA, CLA was performed based on conventional lines, with additional lines. Atrial fibrillation was not induced after PVI alone or with cavotricuspid isthmus ablation in 20.7% of patients. To achieve the endpoint, additional CFAE-guided RA ablation was required in 42.7% and 36.0% of patients undergoing CFA and CLA, respectively (P = 0.403). Atrial fibrillation was terminated during CFAE-guided ablation in 72.9% and 75.0% of patients undergoing CFA and CLA, respectively (P = 0.792). Termination of atrial tachycardia (AT) or non-inducibility of AF/AT was achieved in 61.3% and 68.0% of patients undergoing CFA and CLA, respectively (P = 0.393). The CLA group showed decreased 1-year freedom from AF/AT recurrence (60.0%, CFA vs. 47.3%, CLA; log rank P = 0.085), but no significant difference throughout the follow-up (22.2 ± 21.0 months) (67.1%, CFA vs. 68.9%, CLA; log rank P = 0.298). CONCLUSION: Long-term efficacy of CFAE-guided ablation was unaffected by the ablation technique in patients with non-paroxysmal AF.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad
7.
Circ Arrhythm Electrophysiol ; 11(2): e005019, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29431632

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) is effective for maintenance of sinus rhythm in 50% to 75% of patients with paroxysmal atrial fibrillation, and it is not uncommon for patients to require additional ablation after PVI. We prospectively evaluated the relative effectiveness of 2 post-PVI ablation strategies in paroxysmal atrial fibrillation. METHODS AND RESULTS: A total of 500 patients (mean age, 55.7±11.0 years; 74.6% male) were randomly assigned to undergo ablation by 2 different strategies after PVI: (1) elimination of non-PV triggers (group A, n=250) or (2) stepwise substrate modification including complex fractionated atrial electrogram or linear ablation until noninducibility of atrial tachyarrhythmia was achieved (group B, n=250). During a median follow-up of 26.0 months, 75 (32.2%) patients experienced at least 1 episode of recurrent atrial tachyarrhythmia after the single procedure in group A compared with 105 (43.8%) patients in group B (P value in log-rank test of Kaplan-Meier analysis: 0.012). Competing risk analysis showed that the cumulative incidence of atrial tachycardia was significantly higher in group B compared with group A (P=0.007). With the exception of total ablation time, there were no significant differences in fluoroscopic time or procedure-related complications between the 2 groups. CONCLUSIONS: Elimination of triggers as an end point of ablation in patients with paroxysmal atrial fibrillation decreased long-term recurrence of atrial tachyarrhythmia compared with a noninducibility approach achieved by additional empirical ablation. The post-PVI trigger test is thus a better end point of ablation for paroxysmal atrial fibrillation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/fisiología , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Femenino , Fluoroscopía , Estudios de Seguimiento , Atrios Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
8.
Artículo en Inglés | MEDLINE | ID: mdl-29141843

RESUMEN

BACKGROUND: Circumferential pulmonary vein isolation (CPVI) alone or combined with adjuvant substrate modifications is unsatisfactory for atrial fibrillation (AF) control in nonparoxysmal AF patients. Ablation targeting the fibrotic areas after CPVI (STABLE-SR [Electrophysiological Substrate Ablation in the Left Atrium During Sinus Rhythm]) is a newly evolved substrate modification strategy. METHODS AND RESULTS: In this multicenter, randomized clinical trial, 229 symptomatic nonparoxysmal AF patients were 1:1 randomized to STABLE-SR group (n=114) or conventional STEPWISE group (n=115). In the STABLE-SR group, after CPVI, cavotricuspid isthmus ablation and cardioversion to sinus rhythm, left atrial high-density mapping was performed. Areas with low-voltage and complex electrogram were further homogenized and eliminated, respectively. Dechanneling would be done if necessary. In the STEPWISE group, additional linear lesions and defragmentation were performed.The primary end point was freedom from documented atrial tachyarrhythmias for ≥30 s after a single ablation procedure without antiarrhythmic medications at 18 months. At 18 months, 74.0% of the patients in the STABLE-SR group and 71.5% in the STEPWISE group (hazard ratio, 0.78; 95% confidence interval, 0.47-1.29; P=0.325) achieved success according to intention-to-treat analysis. However, less procedure time (186.8±52.7 versus 210.5±48.0 minutes, P<0.001), reduced post-CPVI fluoroscopic time (11.0±7.8 versus 13.7±8.9 minutes, P=0.006), and shorter energy delivery time (60.1±25.1 versus 75.0±24.3 minutes, P<0.001) were observed in the STABLE-SR group compared with the STEPWISE group. CONCLUSIONS: STABLE-SR is a simplified, personalized, and effective ablation strategy in nonparoxysmal AF patients. More importantly, over 50% nonparoxysmal AF patients do not need further ablation beyond CPVI and therefore can avoid excessive ablation. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01761188.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , China , Electrocardiografía Ambulatoria , Femenino , Frecuencia Cardíaca , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
9.
Clin J Am Soc Nephrol ; 12(4): 653-662, 2017 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-28159828

RESUMEN

BACKGROUND AND OBJECTIVES: Hyperphosphatemia in kidney transplant recipients has been shown to predict poorer graft and patient survival. However, studies examining hypophosphatemia are scarce. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: To evaluate the association of serum phosphorus level with patient and graft survival, we performed a retrospective multicenter cohort study. Between January of 1997 and August of 2012, 2786 kidney transplant recipients (41.7±11.4 years; 59.3% men; 73.5% living donors; 26.1% with diabetes; 3.8% with prior history of cardiovascular disease) were classified into seven groups according to serum phosphorus levels 1 year after transplantation, with intervals of 0.5 mg/dl (lowest group, <2.5 mg/dl; highest group, ≥5.0 mg/dl; reference group, 3.5-3.99 mg/dl). Survival analysis was performed by defining baseline time point as 1 year after transplantation. RESULTS: During median follow-up of 78.5 months, 60 patient deaths and 194 cases of graft loss occurred. In multivariate analysis, both lowest and highest serum phosphorus groups were associated with higher mortality, compared with the reference group (hazard ratio [HR], 4.82; 95% confidence interval [95% CI], 1.36 to 17.02; P=0.01; and HR, 4.24; 95% CI, 1.07 to 16.84; P=0.04, respectively). Higher death-censored graft loss was observed in the lowest and highest groups (HR, 3.32; 95% CI, 1.42 to 7.79; P=0.01; and HR, 2.93; 95% CI, 1.32 to 6.49; P=0.01, respectively), despite eGFR exhibiting no difference between the lowest group and reference group (65.4±19.3 versus 61.9±16.7 ml/min per 1.73 m2; P=0.33). Moreover, serum phosphorus showed a U-shape association with patient mortality and graft failure in restricted cubic spline curve analysis. CONCLUSIONS: Serum phosphorus level 1 year after transplantation exhibits a U-shape association with death-censored graft failure and patient mortality in kidney transplant patients characterized by relatively high rate of living donor transplant and low incidence of diabetes and prior cardiovascular disease compared with Western countries.


Asunto(s)
Supervivencia de Injerto , Hiperfosfatemia/mortalidad , Hipofosfatemia/mortalidad , Trasplante de Riñón/mortalidad , Fósforo/sangre , Adolescente , Adulto , Anciano , Calcio/sangre , Femenino , Estudios de Seguimiento , Humanos , Hiperfosfatemia/sangre , Hipofosfatemia/sangre , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Albúmina Sérica/metabolismo , Tasa de Supervivencia , Adulto Joven
10.
Europace ; 19(10): 1657-1663, 2017 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-27702847

RESUMEN

AIMS: Controversy on the optimal ablation strategy for persistent atrial fibrillation (AF) exists with limited work evaluating a strategy of pulmonary vein isolation (PVI) alone when AF terminates during PVI. Thirty-five patients had AF termination during PVI in the Modified Ablation Guided by Ibutilide Use in Chronic Atrial Fibrillation (MAGIC-AF; ClinicalTrials.gov number: NCT01014741) study. The objective of the current study is to report the 1-year outcome after PVI alone in this unique patient group. METHODS AND RESULTS: The 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs was reported for the 35 patients in the MAGIC-AF study with persistent AF termination during or upon completion of PVI. Freedom from recurrent atrial arrhythmia was achieved in 60% of patients where AF terminated during PVI. Cavotricuspid isthmus flutter was common when AF terminated to a macro re-entrant flutter during PVI, and responsible for 92% of all flutter circuits with AF termination. CONCLUSIONS: Persistent AF termination during PVI may identify a subgroup of patients who experience a similar long-term clinical outcome with PVI ablation alone when compared with other more extensive persistent AF ablation strategies. Pulmonary vein isolation alone may be an appropriate tactic in this subgroup of persistent AF patients.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Aleteo Atrial/etiología , Canadá , Ablación por Catéter/efectos adversos , Supervivencia sin Enfermedad , Método Doble Ciego , Electrocardiografía Ambulatoria , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Recurrencia , Sistema de Registros , República de Corea , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
11.
Arthritis Res Ther ; 18: 91, 2016 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-27090981

RESUMEN

BACKGROUND: Bruton's tyrosine kinase (Btk) is critical for activation of B cells and myeloid cells. This study aimed to characterize the effects of HM71224, a novel Btk inhibitor, both in vitro and in a mouse model of experimental arthritis. METHODS: The kinase inhibition profile of HM71224 was analyzed. The in vitro effects of HM71224 on B cells and monocytes were analyzed by examining phosphorylation of Btk and its downstream signaling molecules, along with cytokine production and osteoclast formation. The in vivo effects of HM71224 were investigated in a mouse model of collagen-induced arthritis (CIA). RESULTS: HM71224 irreversibly bound to and inhibited Btk (IC50 = 1.95 nM). The compound also inhibited the phosphorylation of Btk and its downstream molecules such as PLCγ2, in activated Ramos B lymphoma cells and primary human B cells in a dose-dependent manner. Furthermore, HM71224 effectively inhibited the production of tumor necrosis factor (TNF)-α, interleukin (IL)-6, and IL-1ß by human monocytes, and osteoclast formation by human monocytes. Finally, HM71224 improved experimental arthritis and prevented joint destruction in a murine model of CIA. CONCLUSIONS: HM71224 inhibits Btk in B cells and monocytes and ameliorates experimental arthritis in a mouse model. Thus, HM71224 is a potential novel therapeutic agent for rheumatoid arthritis in humans.


Asunto(s)
Antirreumáticos/farmacología , Artritis Experimental/inmunología , Artritis Reumatoide/inmunología , Activación de Linfocitos/efectos de los fármacos , Proteínas Tirosina Quinasas/antagonistas & inhibidores , Agammaglobulinemia Tirosina Quinasa , Animales , Artritis Experimental/patología , Artritis Reumatoide/patología , Linfocitos B/inmunología , Línea Celular , Citocinas/biosíntesis , Citocinas/inmunología , Citometría de Flujo , Humanos , Immunoblotting , Ratones , Monocitos/inmunología , Osteoclastos/efectos de los fármacos , Osteoclastos/metabolismo , Inhibidores de Proteínas Quinasas/farmacología
12.
Eur Heart J ; 37(20): 1614-21, 2016 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-26850076

RESUMEN

AIMS: Complex fractionated atrial electrograms (CFAE) are targeted during persistent atrial fibrillation (AF) ablation. However, many CFAE sites are non-specific resulting in extensive ablation. Ibutilide has been shown to reduce left atrial surface area exhibiting CFAE. We hypothesized that ibutilide administration prior to CFAE ablation would identify sites critical for persistent AF maintenance allowing for improved procedural efficacy and long-term freedom from atrial arrhythmias. METHODS AND RESULTS: Two hundred patients undergoing a first-ever persistent AF catheter ablation procedure were randomly assigned to receive either 0.25 mg of intravenous ibutilide or saline placebo upon completion of pulmonary vein isolation. Complex fractionated atrial electrogram sites were then targeted with ablation. The primary efficacy endpoint was the 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs. Similar procedural characteristics (procedure, fluoroscopy, and ablation times) were observed with both strategies despite a greater reduction in left atrial surface area with CFAE sites (8 vs. 1%, P < 0.0001) and AF termination during CFAE ablation with ibutilide compared with placebo (75 vs. 57%, P = 0.007). The primary efficacy endpoint was achieved in 56% of patients receiving ibutilide and 49% receiving placebo (P = 0.35). No significant differences in peri-procedural complications were observed in both groups. CONCLUSION: Despite a reduction in CFAE area and greater AF termination during CFAE ablation, procedural characteristics and clinical outcomes were unchanged when CFAE ablation was guided by ibutilide administration. CLINICAL TRIAL REGISTRATION INFORMATION: ClinicalTrials.gov number: NCT01014741.


Asunto(s)
Fibrilación Atrial/tratamiento farmacológico , Sulfonamidas/uso terapéutico , Ablación por Catéter , Enfermedad Crónica , Técnicas Electrofisiológicas Cardíacas , Humanos , Venas Pulmonares , Resultado del Tratamiento
13.
Artículo en Inglés | MEDLINE | ID: mdl-26203268

RESUMEN

BACKGROUND: In phytotherapy, the therapeutic potential is based on the combined action of different herbal drugs. Our objective was to evaluate the antioxidant, anti-collagenase (in vitro), and anti-wrinkle (in vivo) effect of combined formulation containing Ginkgo biloba, Punica granatum, Ficus carica, and Morus alba fruits extract. METHODS: Antioxidant evaluation was based on the scavenging activity of free radicals (1,1-diphenyl-2-picrylhydrazyl, H2O2, and O2 (-)) and the anti-collagenase activity was based on the reduction of collagenase enzyme in vitro. In an in vivo study, 21 female subjects were examined in a placebo-controlled trail. Facial wrinkle, especially the crow's feet region of eyes, was treated with topical formulated 2% cream for 56 days and compared with the placebo. RESULTS: In the in vitro study, the combination of fruits extract showed a higher antioxidant activity which was comparable with the positive standard (ascorbic acid, butylated hydroxyanisole, and Trolox). The data also showed a dose-dependent inhibition of collagenase. In the in vivo study, treatment with 2% formulated cream for 56 days significantly reduced the percentage of wrinkle depth, length, and area with 11.5, 10.07, and 29.55, respectively. CONCLUSION: The combined formulation of fruit extracts showed excellent antioxidative and anti-collagenase activity as well as a significant effect on anti-wrinkle activity on human skin.

14.
Int J Cardiovasc Imaging ; 31(6): 1191-9, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25957631

RESUMEN

The complex fractioned atrial electrogram (CFAE) has been considered as the catheter ablation target of left atrium (LA) under persistent atrial fibrillation (PeAF). We evaluated the relation between the LA wall composition by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) and the CFAE in patients with PeAF. Forty-three patients underwent LGE-CMR and CFAE mapping before catheter ablation for PeAF. The LA wall substrates were classified into three: the fibrotic, intermediate, and normal substrates by using two thresholds of 2 standard deviation (2-SD) and 6-SD above the mean signal from the normal myocardium. For each of 12 preselected LA wall regions, the composition ratios (CRs) of fibrotic, indeterminate, and normal substrates were calculated as a percentage to the volume of LA wall region, and compared depending on the CFAE, respectively. The CR of normal substrate was significantly greater at the LA wall region with CFAE (52 ± 38% vs. 20 ± 28%, P < 0.01) than without CFAE. In contrast, the LA wall region with CFAE showed significantly lower CRs of intermediate substrate (39 ± 34% vs. 57 ± 31%, P < 0.01) and fibrotic substrate (7 ± 17% vs. 21 ± 24%, P < 0.01) than did the LA wall region without CFAE, respectively. Thus, the high CR (>18%) of normal substrate predicted the CFAE at the corresponding LA wall region with 71% sensitivity and 62% specificity. In conclusion, the evaluation of LA wall normal substrate by LGE-CMR might be useful to predict the CFAE occurrence before catheter ablation of PeAF.


Asunto(s)
Fibrilación Atrial/diagnóstico , Función del Atrio Izquierdo , Medios de Contraste , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/patología , Atrios Cardíacos/fisiopatología , Imagen por Resonancia Magnética , Meglumina , Compuestos Organometálicos , Potenciales de Acción , Fibrilación Atrial/patología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter , Estudios de Factibilidad , Femenino , Fibrosis , Atrios Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos
15.
Europace ; 17(9): 1391-401, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25736564

RESUMEN

AIMS: Atrial fibrillation (AF) cycle length (CL) has been demonstrated to be one of the predictors for termination during ablation for AF. We evaluated the AF CL gradient between right atrium (RA) and left atrium (LA) and their mean AF CL in predicting the extent of substrate ablation. METHODS AND RESULTS: One-hundred and thirty-six patients undergoing first ablation for persistent AF were studied. Stepwise ablation, sequentially in the following order: pulmonary veins (PV), LA, and RA, was performed to achieve AF termination. Stepwise ablation terminated AF in 110 patients (81%). In the AF termination group, AF was terminated by PV isolation (PVI) (Group P), PVI plus LA ablation (Group L), and PVI plus LA plus RA ablation (Group R) in 14 patients (13%), 49 patients (44%), and 47 patients (43%), respectively. Group R had much shorter mean AF CL than Group L (156 ± 18 vs. 174 ± 24 ms, P < 0.001) and mean AF CL in Group L was much shorter than Group P (174 ± 24 vs. 209 ± 36 ms, P = 0.004). The RA to LA AF CL gradient was not significantly different between left-side ablation (Group P + Group L) and additional RA ablation (Group R) (P = 0.177). Mean AF CL >180.50 ms predicted AF termination by PVI (Group P) with 79% sensitivity and 84% specificity while mean AF CL >165.25 ms predicted AF termination by left-side ablation (Group P + Group L) with 67% sensitivity and 75% specificity. After a mean follow-up of 15 ± 7 months, freedom from arrhythmia recurrence was significantly higher in left-side ablation (Group P + Group L) than additional RA ablation (Group R) (P = 0.024). CONCLUSION: Baseline mean AF CL may identify the subset of patients in whom persistent AF can be terminated by different extent of substrate ablation, which may in turn predict the chance of recurrence. However, baseline RA to LA AF CL gradient cannot predict the need for additional RA ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/fisiopatología , Venas Pulmonares/cirugía , Anciano , Electrocardiografía , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Pronóstico , Recurrencia , Sensibilidad y Especificidad
16.
Europace ; 17(11): 1700-7, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25736723

RESUMEN

AIMS: The interatrial septal thickness (IAST) reflects the changes of the atrial wall in patients with atrial fibrillation (AF). Complex fractionated atrial electrograms (CFAEs) were consistently positioned on the interatrial septum, especially in the remodelled left atrium (LA). We sought to characterize the relationship between IAST and LA CFAE area, as well as the acute procedural and clinical outcomes of catheter ablation in persistent AF patients. METHODS AND RESULTS: This study included 71 patients who underwent catheter ablation for drug-refractory persistent AF. A stepwise ablation approach included circumferential pulmonary vein isolation followed by LA and right atrial CFAE-guided ablation. Interatrial septal thickness was measured 1 cm inferior to the fossa ovalis on cardiac computed tomography (CT). The extent of LA CFAEs was assessed by CFAE area and index (CFAE area/LA surface area × 100). Patients were grouped into tertiles according to the value of IAST. The mean IAST of the first, second, and third tertile was 4.69 ± 0.79, 6.44 ± 0.45, and 9.12 ± 1.42 mm, respectively (P < 0.001). The mean CFAE areas (5.6 ± 6.9, 18.5 ± 20.3, and 24.3 ± 26.6 mm(2), P = 0.005) and CFAE indexes (3.1 ± 4.2, 9.2 ± 10.7, and 11.8 ± 15.3, P = 0.025) in LA were significantly different among the three groups. More patients in the highest IAST tertile did not terminate AF during catheter ablation (12.5% vs. 26.1% vs. 37.5%, P = 0.048). CONCLUSIONS: Interatrial septal thickness measured by cardiac CT is associated with the extent of CFAE area within the LA and is related to acute procedural success of catheter ablation. These findings suggest that IAST reflects the degree of atrial substrate and remodelling in patients with persistent AF.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Función del Atrio Izquierdo , Remodelación Atrial , Tabique Interatrial/diagnóstico por imagen , Tabique Interatrial/fisiopatología , Tabique Interatrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Tomografía Computarizada Multidetector , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Resultado del Tratamiento
17.
Int J Cardiovasc Imaging ; 31 Suppl 1: 91-101, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25367893

RESUMEN

By using late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) imaging, we compared left atrial late gadolinium enhancement (LA-LGE) quantification methods based on different references to characterize the left atrial wall in patients with atrial fibrillation (AF). Thirty-eight patients who underwent three-dimensional LGE-CMR imaging before catheter ablation for AF were classified into three groups depending on their clinical AF type: (1) paroxysmal AF (PAF; n = 12); (2) persistent AF (PeAF; n = 16); and (3) recurrent AF after catheter ablation (RAF; n = 10). To quantify LA-LGE on LGE-CMR imaging, we used the thresholds of 2 standard deviations (2-SD), 3-SD, 4-SD, 5-SD, or 6-SD above the mean signal from the unenhanced left ventricular myocardium, and we used the full width at half maximum (FWHM) technique, which was based on the maximum signal from the mitral valve with high signal intensity. The 6-SD threshold and FWHM techniques were statistically reproducible with an intraclass correlation coefficient >0.7. On applying the FWHM technique, the normalized LA-LGE volume by LA wall area showed a significant difference between the RAF, PeAF, and PAF groups (0.22 ± 0.04, 0.16 ± 0.06, and 0.09 ± 0.03 mL/cm(2), respectively) (P < 0.05). Furthermore, most of the fibrotic scarring and low-voltage tissue on the electroanatomic map corresponded well with the extent of LA-LGE. The FWHM technique based on the mitral valve can provide a reproducible quantification of LA-LGE related to AF in the thin LA wall.


Asunto(s)
Fibrilación Atrial/patología , Medios de Contraste , Atrios Cardíacos/patología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Meglumina , Compuestos Organometálicos , Anciano , Algoritmos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Función del Atrio Izquierdo , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Estudios de Factibilidad , Femenino , Fibrosis , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
18.
Asian-Australas J Anim Sci ; 27(11): 1652-62, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25358327

RESUMEN

The present study investigated the optimum blending condition of protected fat, choline and yeast culture for lowering of rumen temperature. The Box Benken experimental design, a fractional factorial arrangement, and response surface methodology were employed. The optimum blending condition was determined using the rumen simulated in vitro fermentation. An additive formulated on the optimum condition contained 50% of protected fat, 25% of yeast culture, 5% of choline, 7% of organic zinc, 6.5% of cinnamon, and 6.5% of stevioside. The feed additive was supplemented at a rate of 0.1% of diet (orchard grass:concentrate, 3:7) and compared with a control which had no additive. The treatment resulted in lower volatile fatty acid (VFA) concentration and biogas than the control. To investigate the effect of the optimized additive and feed energy levels on rumen and rectal temperatures, four rumen cannulated Hanwoo (Korean native beef breed) steers were in a 4×4 Latin square design. Energy levels were varied to low and high by altering the ratio of forage to concentrate in diet: low energy (6:4) and high energy (4:6). The additive was added at a rate of 0.1% of the diet. The following parameters were measured; feed intake, rumen and rectal temperatures, ruminal pH and VFA concentration. This study was conducted in an environmentally controlled house with temperature set at 30°C and relative humidity levels of 70%. Steers were housed individually in raised crates to facilitate collection of urine and feces. The adaptation period was for 14 days, 2 days for sampling and 7 days for resting the animals. The additive significantly reduced both rumen (p<0.01) and rectal temperatures (p<0.001) without depressed feed intake. There were interactions (p<0.01) between energy level and additive on ruminal temperature. Neither additive nor energy level had an effect on total VFA concentration. The additive however, significantly increased (p<0.01) propionate and subsequently had lower acetate:propionate (A/P) ratios than non-additive supplementation. High concentrate diets had significantly lower pH. Interactions between energy and additive were observed (p<0.01) in ammonia nitrogen production. Supplementation of diets with the additive resulted in lower rumen and rectal temperatures, hence the additive showed promise in alleviating undesirable effects of heat stress in cattle.

19.
Korean J Radiol ; 15(1): 29-36, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24497789

RESUMEN

OBJECTIVE: To assess the feasibility of computed tomography (CT) lymphography using ethiodized oil for sentinel node mapping in experimentally induced VX2 carcinoma in the rabbit thigh. MATERIALS AND METHODS: This experiment received approval from the institutional animal use and care administrative advisory committee. Twenty-three rabbits with VX2 carcinoma in the thigh underwent CT before and after (1 hour, 2 hour) peritumoral injection of 2 mL ethiodized oil. After the CT examination, sentinel nodes were identified by peritumoral injection of methylene blue and subsequently removed. The retrieved sentinel and non-sentinel lymph nodes were investigated with radiographic and pathologic examinations. Based on the comparison of CT findings with those of radiographic and pathologic examinations, the diagnostic performance of CT for sentinel node identification was assessed. RESULTS: All 23 rabbits showed 53 ethiodized oil retention nodes on post-injection CT and specimen radiography, and 52 methylene blue-stained nodes at the right femoroiliac area. Of the 52 blue-stained sentinel nodes, 50 nodes demonstrated ethiodized oil retention. Thus, the sentinel node detection rate of CT was 96% (50 of 52). On pathologic examination, 28 sentinel nodes in 17 rabbits (nodes/rabbit, mean ± standard deviation, 1.7 ± 0.6) harbored metastasis. Twenty seven of the 28 metastatic sentinel nodes were found to have ethiodized oil retention. CONCLUSION: Computed tomography lymphography using ethiodized oil may be feasible for sentinel node mapping in experimentally induced VX2 carcinoma in the rabbit thigh.


Asunto(s)
Carcinoma/diagnóstico por imagen , Medios de Contraste , Aceite Etiodizado , Ganglios Linfáticos/diagnóstico por imagen , Linfografía/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Carcinoma/patología , Carcinoma/secundario , Estudios de Factibilidad , Femenino , Inyecciones , Escisión del Ganglio Linfático/métodos , Ganglios Linfáticos/patología , Metástasis Linfática/diagnóstico por imagen , Conejos , Muslo
20.
J Cardiovasc Electrophysiol ; 25(2): 146-53, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24118250

RESUMEN

INTRODUCTION: Complex fractionated atrial electrograms (CFAEs) are a substrate modification target in patients with atrial fibrillation (AF). However, whether CFAEs can be also arrhythmogenic grounds of atrial tachycardia (AT) presenting after AF ablation remains to be determined. We investigated the relationship between CFAEs and the critical site of AT after CFAE-guided AF ablation. METHODS AND RESULTS: Seventy-two patients showing AT after pulmonary vein isolation and further CFAE-guided ablation were included. The termination sites of the 95 distinct ATs were annotated on color-coded CFAE cycle maps. Of the 95 ATs, 61 (64.2%) had a termination site at the border zone of CFAE or in a highly dense CFAE area. The cycle length (CL) of the ATs terminated in the CFAE area was significantly shorter than the CL of those terminated in the non-CFAE area. The cut-off CL for ATs terminated at the CFAE area was 270 milliseconds, with sensitivity/specificity of 70%/75%. In 67.2% of the ATs terminating at the CFAE-related area, the major termination sites were the anterior wall near the LA appendage, septum and roof, whereas the peri-mitral isthmus was the most common termination site of ATs in the non-CFAE area. CONCLUSIONS: The areas showing CFAE and their border zones were frequently associated with termination of ATs presenting after AF ablation. The mean CL of ATs originating near CFAEs was significantly shorter than that of those terminated in non-CFAE areas. The targeted CFAE areas also provided the arrhythmogenic milieu for AT developing after AF ablation.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Taquicardia Atrial Ectópica/diagnóstico , Taquicardia Atrial Ectópica/etiología , Adulto , Anciano , Fibrilación Atrial/complicaciones , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Cirugía Asistida por Computador , Taquicardia Atrial Ectópica/prevención & control , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA