Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Revista
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Heart ; 105(7): 538-544, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30377259

RESUMEN

BACKGROUND: Tachyarrhythmias and bradyarrhythmias affect 20%-50% of adult patients with tetralogy of Fallot (TOF) and some of these patients will require cardiac implantable electronic devices (CIED) such as pacemaker and/or internal cardioverter defibrillator. METHODS: The Mayo Adult Congenital Heart Disease database was queried for patients with repaired TOF and history of CIED implantation, 1990-2017. The study objectives were: (1) determine the occurrence of device-related complications defined as lead failure, lead recall, device infection and lead thrombus; and (2) determine the occurrence and risk factors for defibrillator shock. RESULTS: There were 99 patients (age 46±14 years and 66 (66%) men) with CIED, and the CIEDs were 41 (41%) pacemakers and 73 (73%) defibrillators. Indication for defibrillator implantation was for primary prevention in 28 (38%) and secondary prevention in 45 (62%). Device-related complications occurred in 20 (20%) patients (lead failure 17, lead recall 4, device infection 12 and thrombus 3). Twenty-five per cent of all device infections occurred within 30 days from the time of device generator change. Annualised rates of appropriate and inappropriate shocks were 5.7% and 6.2%, respectively. The use of class III antiarrhythmic drug was protective against defibrillator shock. CONCLUSION: The current study provides useful outcome data to aid patient counselling and clinical decision-making. Further studies are required to explore ways to decrease the risk of postprocedural infection after device generator change, and to determine which patients will benefit from empirical antiarrhythmic therapy as a strategy to decrease incidence of inappropriate defibrillator shock.


Asunto(s)
Arritmias Cardíacas , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/efectos adversos , Terapia por Estimulación Eléctrica , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis , Tetralogía de Fallot/complicaciones , Adulto , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/prevención & control , Arritmias Cardíacas/terapia , Desfibriladores Implantables/normas , Remoción de Dispositivos/métodos , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Electrocardiografía/métodos , Análisis de Falla de Equipo , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Evaluación de Necesidades , Evaluación de Procesos y Resultados en Atención de Salud , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/prevención & control , Estudios Retrospectivos , Tetralogía de Fallot/epidemiología , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA