Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Crit Care Med ; 48(3): e219-e226, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31904685

RESUMEN

OBJECTIVES: To evaluate the effect of esophageal stimulation on nutritional adequacy in critically ill patients at risk for enteral feeding intolerance. DESIGN: A multicenter randomized sham-controlled clinical trial. SETTING: Twelve ICUs in Canada. PATIENTS: We included mechanically ventilated ICU patients who were given moderate-to-high doses of opioids and expected to remain alive and ventilated for an additional 48 hours and who were receiving enteral nutrition or expected to start imminently. INTERVENTIONS: Patients were randomly assigned 1:1 to esophageal stimulation via an esophageal stimulating catheter (E-Motion Tube; E-Motion Medical, Tel Aviv, Israel) or sham treatment. All patients were fed via these catheters using a standardized feeding protocol. MEASUREMENTS AND MAIN RESULTS: The co-primary outcomes were proportion of caloric and protein prescription received enterally over the initial 7 days following randomization. Among 159 patients randomized, the modified intention-to-treat analysis included 155 patients: 73 patients in the active treatment group and 82 in the sham treatment group. Over the 7-day study period, the percent of prescribed caloric intake (± SE) received by the enteral route was 64% ± 2 in the active group and 65% ± 2 in sham patients for calories (difference, -1; 95% CI, -8 to 6; p = 0.74). For protein, it was 57% ± 3 in the active group and 60% ± 3 in the sham group (difference, -3; 95% CI, -10 to 3; p = 0.30). Compared to the sham group, there were more serious adverse events reported in the active treatment group (13 vs 6; p = 0.053). Clinically important arrhythmias were detected by Holter monitoring in 36 out of 70 (51%) in the active group versus 22 out of 76 (29%) in the sham group (p = 0.006). CONCLUSIONS: Esophageal stimulation via a special feeding catheter did not improve nutritional adequacy and was associated with increase risk of harm in critically ill patients.


Asunto(s)
Enfermedad Crítica/terapia , Terapia por Estimulación Eléctrica/métodos , Nutrición Enteral/métodos , Esófago/fisiología , Motilidad Gastrointestinal/fisiología , Reflujo Laringofaríngeo/prevención & control , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Unidades de Cuidados Intensivos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Estado Nutricional , Respiración Artificial , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA