Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Métodos Terapéuticos y Terapias MTCI
Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Refract Surg ; 27(3): 189-94, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20540471

RESUMEN

PURPOSE: To report 1-year follow-up in 11 of 13 eyes with keratoconus treated by deep anterior lamellar keratoplasty with a combined femtosecond laser lamellar resection followed by a big-bubble dissection. METHODS: Thirteen eyes with keratoconus were treated. Recipient and donor were prepared with the 60-kHz IntraLase femtosecond laser (Abbott Medical Optics). In the recipient, the femtosecond laser, after performing a lamellar cut 100 µm above the thinnest corneal point (measured by Pentacam [Oculus Optikgeräte GmbH]), was used to make a mushroom-shaped resection (anterior diameter, 9 mm; posterior diameter, 8 mm) from the same depth. In the donor, the mushroom lamellar thickness was calculated according to an original model based on the recipient preoperative corneal thickness. Upon removal of the recipient lamella, air was injected into the residual stroma to achieve a big bubble. The keratectomy was continued up to Descemet membrane. The donor was fit into place and sutured using interrupted sutures, which were removed by 8 months postoperative. Corrected distance visual acuity (CDVA) and refractive astigmatism were calculated by manifest refraction, whereas topographic astigmatism and corneal thickness were measured by Pentacam. RESULTS: A big bubble was successfully achieved in 11 eyes. Twelve months after surgery, mean CDVA was 0.52±1.2 (decimal), and refractive sphere and cylinder were -1.50±1.70 diopters (D) and 2.00±2.60 D, respectively. Three (27%) of 11 eyes at 1 year had a manifest refraction spherical equivalent within 1.00 D of emmetropia. Topographic astigmatism was 2.90±1.60 D. The thinnest corneal point was 519±27 µm. CONCLUSIONS: This combination of a femtosecond laser lamellar dissection with a big-bubble technique can improve the standardization of deep anterior lamellar keratoplasty for keratoconus.


Asunto(s)
Trasplante de Córnea , Queratocono/cirugía , Láseres de Excímeros/uso terapéutico , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Adolescente , Adulto , Topografía de la Córnea , Estudios de Seguimiento , Humanos , Complicaciones Intraoperatorias , Complicaciones Posoperatorias , Estudios Retrospectivos , Técnicas de Sutura , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA