Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Am J Ophthalmol ; 147(1): 162-170.e1, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18571617

RESUMEN

PURPOSE: To investigate the long-term outcome of the Bioceramic orbital implant. DESIGN: A retrospective, comparative, nonrandomized study. METHODS: Data were collected from the patients receiving Bioceramic orbital implants at National Taiwan University Hospital between June 1, 2001 and November 1, 2005. The implant was wrapped with Vicryl mesh, adding anteriorly with a scleral patch graft following enucleation with primary or secondary implantation. The unwrapped implant was inserted into an eviscerated globe with posterior sclerotomy and cornea preserved. Primary or secondary placement of sleeve was performed in some patients. RESULTS: A total of 112 cases were reviewed. Four patients were excluded attributable to insufficient follow-up. The other 108 patients had a mean follow-up period of 35.8 +/- 10.6 months (range, 24 to 70 months). Fifty patients (46.3%) received the pegging procedure. Eight of 108 (7.4%) cases of late exposure were identified on average 20.7 months after implantation. We identified no cases of implant exposure in 30 cases of enucleation and eight cases of secondary implant when the implant was wrapped in Vicryl mesh and an anterior scleral cap was used. All exposures developed in eviscerated patients (70 cases): two without pegging, three with primary placement, and three with secondary placement of the sleeve. The exposure rate was higher in patients with eviscerated globes, pegged implants, and prior ocular operations (P < .005). CONCLUSIONS: Late exposures of Bioceramic implants were found after long-term follow-up, associated with evisceration, pegging, and prior ocular surgeries. The modified wrapping technique can prevent exposure following secondary implantation and enucleation.


Asunto(s)
Óxido de Aluminio , Cerámica , Órbita/cirugía , Implantes Orbitales , Complicaciones Posoperatorias , Dehiscencia de la Herida Operatoria/etiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles , Niño , Preescolar , Enucleación del Ojo , Evisceración del Ojo , Ojo Artificial , Femenino , Estudios de Seguimiento , Humanos , Lactante , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Implantación de Prótesis , Estudios Retrospectivos , Adulto Joven
2.
Ophthalmic Surg Lasers Imaging ; 39(5): 399-403, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18831423

RESUMEN

A patient with a painful, blind eye underwent enucleation and bioceramic orbital implantation. The bio-ceramic implant was wrapped with polyglactin 910 mesh and anteriorly capped with a scleral patch graft. Because there was tension on the wound, a relaxing conjunctival incision on the fornix was performed. Implant exposure with a diameter of 9 mm occurred 4 months after surgery. The exposed bioceramic implant was successfully repaired by a retroauricular myoperiosteal graft. The graft contains myofibrovascularized tissue, provides durable and vascularized coverage of exposed implants, and only requires a nearby harvesting site. The exposure completely resolved without recurrence after 2 years of follow-up.


Asunto(s)
Pabellón Auricular , Migración de Cuerpo Extraño/cirugía , Músculo Esquelético/trasplante , Implantes Orbitales , Periostio , Complicaciones Posoperatorias , Anciano , Óxido de Aluminio , Materiales Biocompatibles , Cerámica , Enucleación del Ojo , Humanos , Masculino , Técnicas de Sutura
3.
Kaohsiung J Med Sci ; 21(9): 433-7, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16248129

RESUMEN

We describe the first case of a Chinese patient with circumscribed choroidal hemangioma (CCH) effectively managed using transpupillary thermotherapy (TTT). A 57-year-old man had an elevated orange-red subretinal mass with a base of 5 x 5 mm superior to the optic disc, along with serous macular detachment in the left eye. Ultrasonography depicted a mass 3 mm thick with acoustic solidity and high internal reflectivity. Fluorescein angiography showed an area of hyperfluorescence in the prearterial phase and tumor staining in the late phase, consistent with a diagnosis of CCH. Therefore, TTT (spot size, 3 mm; exposure, 1 min) was performed with a diode laser, delivered through a slit-lamp biomicroscope. The laser power was first set at 300 mW and then increased in 50-mW increments, until test shots in the mid-peripheral retina outside the lesion produced a slightly grayish appearance in the irradiated area. The tumor was covered with four overlapping laser spots and subjected to an average beam power of 400 mW. Best-corrected visual acuity increased from 20/50 before treatment, to 20/20 3 months following one session of TTT. The lesion became atrophic and the subretinal fluid disappeared. Our experience shows that TTT can be an even more effective treatment strategy for CCH in Asians than in Caucasians. In Chinese patients, the power level of the diode laser should be lower than that used in Caucasians.


Asunto(s)
Neoplasias de la Coroides/terapia , Hemangioma/terapia , Hipertermia Inducida/métodos , Humanos , Coagulación con Láser , Masculino , Persona de Mediana Edad , Pupila
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA