Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Schizophr Bull ; 49(5): 1375-1386, 2023 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-37078906

RESUMEN

BACKGROUND AND HYPOTHESIS: Schizophrenia is a polygenetic mental disorder with heterogeneous positive and negative symptom constellations, and is associated with abnormal cortical connectivity. The thalamus has a coordinative role in cortical function and is key to the development of the cerebral cortex. Conversely, altered functional organization of the thalamus might relate to overarching cortical disruptions in schizophrenia, anchored in development. STUDY DESIGN: Here, we contrasted resting-state fMRI in 86 antipsychotic-naive first-episode early-onset schizophrenia (EOS) patients and 91 typically developing controls to study whether macroscale thalamic organization is altered in EOS. Employing dimensional reduction techniques on thalamocortical functional connectome (FC), we derived lateral-medial and anterior-posterior thalamic functional axes. STUDY RESULTS: We observed increased segregation of macroscale thalamic functional organization in EOS patients, which was related to altered thalamocortical interactions both in unimodal and transmodal networks. Using an ex vivo approximation of core-matrix cell distribution, we found that core cells particularly underlie the macroscale abnormalities in EOS patients. Moreover, the disruptions were associated with schizophrenia-related gene expression maps. Behavioral and disorder decoding analyses indicated that the macroscale hierarchy disturbances might perturb both perceptual and abstract cognitive functions and contribute to negative syndromes in patients. CONCLUSIONS: These findings provide mechanistic evidence for disrupted thalamocortical system in schizophrenia, suggesting a unitary pathophysiological framework.


Asunto(s)
Trastornos Psicóticos , Esquizofrenia , Humanos , Esquizofrenia/diagnóstico por imagen , Corteza Cerebral/diagnóstico por imagen , Imagen por Resonancia Magnética , Tálamo/diagnóstico por imagen , Vías Nerviosas
2.
J Glaucoma ; 32(7): 585-592, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37055937

RESUMEN

PRCIS: Lamina cribrosa (LC) thinning (thickness of ≤128.00 µm) helps to distinguish open angle glaucoma from high myopia, which was associated with the presence of microvasculature dropout and elevated intraocular pressure. PURPOSE: The purpose of this study was to analyze the factors associated with LC thickness in highly myopic eyes with and without open angle glaucoma. METHODS: In total, 240 highly myopic eyes with γ-zones (194 eyes without and 46 eyes with open angle glaucoma) were examined, and the LC center, externally oblique border, an abrupt change of scleral curvature (scleral step), deep layer microvasculature dropout and global retinal nerve fiber layer thickness were investigated on optical coherence tomography and optical coherence tomography angiography. RESULTS: LC were thinner in highly myopic open angle glaucoma compared with high myopia alone (107.76±9.86 vs. 137.07±18.51 µm, P <0.001), which was associated with deep layer microvasculature dropout and elevated intraocular pressure. The areas under the receiver operating characteristic curve for detecting open angle glaucoma from the LC thickness was 0.964, which was statistically higher ( P <0.05) than from the global retinal nerve fiber layer thickness (0.921) and vertical cup-to-disc ratio (0.902). A LC thickness cutoff value of 128 µm provided 100% sensitivity for detecting open angle glaucoma with 84% specificity. CONCLUSIONS: Highly myopic eyes with open angle glaucoma appear to have a thinner LC, which was associated with elevated intraocular pressure and deep layer microvasculature dropout. LC thinning (≤128.00 µm) helps distinguish open angle glaucoma from high myopia with an abnormal retinal nerve fiber layer thickness distribution and unclear shallow disc cupping.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Miopía , Disco Óptico , Humanos , Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Ángulo Abierto/complicaciones , Disco Óptico/irrigación sanguínea , Presión Intraocular , Glaucoma/complicaciones , Miopía/complicaciones , Miopía/diagnóstico , Tomografía de Coherencia Óptica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA