Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anesth Analg ; 109(1): 265-71, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19535720

RESUMEN

BACKGROUND: Visualization with ultrasound during regional anesthesia may reduce the risk of intraneural injection and subsequent neurological symptoms but has not been formally assessed. Thus, we performed this randomized clinical trial comparing ultrasound versus nerve stimulator-guided interscalene blocks for shoulder arthroscopy to determine whether ultrasound could reduce the incidence of postoperative neurological symptoms. METHODS: Two hundred thirty patients were randomized to a standardized interscalene block with either ultrasound or nerve stimulator with a 5 cm, 22 g Stimuplex insulated needle with 1.5% mepivacaine with 1:300,000 epinephrine and NaCO3 (1 meq/10 mL). A standardized neurological assessment tool (questionnaire and physical examination) designed by a neurologist was administered before surgery (both components), at approximately 1 wk after surgery (questionnaire), and at approximately 4-6 weeks after surgery (both components). Diagnosis of postoperative neurological symptoms was determined by a neurologist blinded to block technique. RESULTS: Two hundred nineteen patients were evaluated. Use of ultrasound decreased the number of needle passes for block performance (1 vs 3, median, P < 0.001), enhanced motor block at the 5-min assessment (P = 0.04) but did not decrease block performance time (5 min for both). No patient required conversion to general anesthesia for failed block, and patient satisfaction was similar in both groups (96% nerve stimulator and 92% ultrasound). The incidence of postoperative neurological symptoms was similar at 1 wk follow-up with 11% (95% CI of 5%-17%) for nerve stimulator and 8% (95% CI of 3%-13%) for ultrasound and was similar at late follow-up with 7% (95% CI of 3%-12%) for nerve stimulator and 6% (95% CI of 2%-11%) for ultrasound. The severity of postoperative neurological symptoms was similar between groups with a median patient rating of moderate. Symptoms were primarily sensory and consisted of pain, tingling, or paresthesias. CONCLUSIONS: Ultrasound reduced the number of needle passes needed to perform interscalene block and enhanced motor block at the 5 min assessment; however, we did not observe significant differences in block failures, patient satisfaction or incidence, and severity of postoperative neurological symptoms.


Asunto(s)
Procedimientos Quirúrgicos Ambulatorios/métodos , Terapia por Estimulación Eléctrica/métodos , Bloqueo Nervioso/métodos , Complicaciones Posoperatorias/cirugía , Hombro/cirugía , Ultrasonografía Intervencional/métodos , Adulto , Procedimientos Quirúrgicos Ambulatorios/instrumentación , Terapia por Estimulación Eléctrica/instrumentación , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Bloqueo Nervioso/instrumentación , Enfermedades del Sistema Nervioso/diagnóstico por imagen , Enfermedades del Sistema Nervioso/etiología , Enfermedades del Sistema Nervioso/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen , Estudios Prospectivos , Hombro/diagnóstico por imagen , Ultrasonografía Intervencional/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA